Experiment and numerical investigations of S700 high strength steel CHS beam-columns after exposure to fire

This paper presents a comprehensive experimental investigation of S700 cold-formed high strength steel circular hollow section beam-columns after exposure to fire. The experimental investigation was performed on two series of S700 cold-formed high strength steel circular hollow section beam-columns...

全面介紹

Saved in:
書目詳細資料
主要作者: Koh, Alvin Zhan Wei
其他作者: Zhao Ou
格式: Final Year Project
語言:English
出版: Nanyang Technological University 2021
主題:
在線閱讀:https://hdl.handle.net/10356/149409
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Nanyang Technological University
語言: English
實物特徵
總結:This paper presents a comprehensive experimental investigation of S700 cold-formed high strength steel circular hollow section beam-columns after exposure to fire. The experimental investigation was performed on two series of S700 cold-formed high strength steel circular hollow section beam-columns specimens with two different dimensions (139.7 × 10 and 168.3 × 4) to study the structural performance of Class 1 and Class 4 structural members. Each series comprised five geometrically identical specimens, with four heated to different levels of high temperatures (namely 400 °C, 600 °C, 900 °C and 1100 °C) and one unheated to simulate ambient temperature. The heating and cooling procedure, material tests, initial global geometric imperfection measurements and eccentric compression tests were performed and fully reported. Due to the absence of codified post-fire design rules, the test and numerical results were employed to evaluate the applicability of codified interaction formulae for high strength steel circular hollow section beam-columns at ambient temperatures, as prescribed in European code, American specification and Australian standard, to the design of post-fire S700 high strength steel circular hollow section beam-columns. The results concluded that European code leads to safe but conservative and scattered failure load predictions, while American specification and Australian standard yield safe, accurate and consistent failure load predictions with the most accurate predictions obtained from the American specification.