Experiment and numerical investigations of S700 high strength steel CHS beam-columns after exposure to fire

This paper presents a comprehensive experimental investigation of S700 cold-formed high strength steel circular hollow section beam-columns after exposure to fire. The experimental investigation was performed on two series of S700 cold-formed high strength steel circular hollow section beam-columns...

Full description

Saved in:
Bibliographic Details
Main Author: Koh, Alvin Zhan Wei
Other Authors: Zhao Ou
Format: Final Year Project
Language:English
Published: Nanyang Technological University 2021
Subjects:
Online Access:https://hdl.handle.net/10356/149409
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-149409
record_format dspace
spelling sg-ntu-dr.10356-1494092021-05-18T05:28:49Z Experiment and numerical investigations of S700 high strength steel CHS beam-columns after exposure to fire Koh, Alvin Zhan Wei Zhao Ou School of Civil and Environmental Engineering ou.zhao@ntu.edu.sg Engineering::Civil engineering::Structures and design This paper presents a comprehensive experimental investigation of S700 cold-formed high strength steel circular hollow section beam-columns after exposure to fire. The experimental investigation was performed on two series of S700 cold-formed high strength steel circular hollow section beam-columns specimens with two different dimensions (139.7 × 10 and 168.3 × 4) to study the structural performance of Class 1 and Class 4 structural members. Each series comprised five geometrically identical specimens, with four heated to different levels of high temperatures (namely 400 °C, 600 °C, 900 °C and 1100 °C) and one unheated to simulate ambient temperature. The heating and cooling procedure, material tests, initial global geometric imperfection measurements and eccentric compression tests were performed and fully reported. Due to the absence of codified post-fire design rules, the test and numerical results were employed to evaluate the applicability of codified interaction formulae for high strength steel circular hollow section beam-columns at ambient temperatures, as prescribed in European code, American specification and Australian standard, to the design of post-fire S700 high strength steel circular hollow section beam-columns. The results concluded that European code leads to safe but conservative and scattered failure load predictions, while American specification and Australian standard yield safe, accurate and consistent failure load predictions with the most accurate predictions obtained from the American specification. Bachelor of Engineering (Civil) 2021-05-18T05:28:49Z 2021-05-18T05:28:49Z 2021 Final Year Project (FYP) Koh, A. Z. W. (2021). Experiment and numerical investigations of S700 high strength steel CHS beam-columns after exposure to fire. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/149409 https://hdl.handle.net/10356/149409 en application/pdf Nanyang Technological University
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Civil engineering::Structures and design
spellingShingle Engineering::Civil engineering::Structures and design
Koh, Alvin Zhan Wei
Experiment and numerical investigations of S700 high strength steel CHS beam-columns after exposure to fire
description This paper presents a comprehensive experimental investigation of S700 cold-formed high strength steel circular hollow section beam-columns after exposure to fire. The experimental investigation was performed on two series of S700 cold-formed high strength steel circular hollow section beam-columns specimens with two different dimensions (139.7 × 10 and 168.3 × 4) to study the structural performance of Class 1 and Class 4 structural members. Each series comprised five geometrically identical specimens, with four heated to different levels of high temperatures (namely 400 °C, 600 °C, 900 °C and 1100 °C) and one unheated to simulate ambient temperature. The heating and cooling procedure, material tests, initial global geometric imperfection measurements and eccentric compression tests were performed and fully reported. Due to the absence of codified post-fire design rules, the test and numerical results were employed to evaluate the applicability of codified interaction formulae for high strength steel circular hollow section beam-columns at ambient temperatures, as prescribed in European code, American specification and Australian standard, to the design of post-fire S700 high strength steel circular hollow section beam-columns. The results concluded that European code leads to safe but conservative and scattered failure load predictions, while American specification and Australian standard yield safe, accurate and consistent failure load predictions with the most accurate predictions obtained from the American specification.
author2 Zhao Ou
author_facet Zhao Ou
Koh, Alvin Zhan Wei
format Final Year Project
author Koh, Alvin Zhan Wei
author_sort Koh, Alvin Zhan Wei
title Experiment and numerical investigations of S700 high strength steel CHS beam-columns after exposure to fire
title_short Experiment and numerical investigations of S700 high strength steel CHS beam-columns after exposure to fire
title_full Experiment and numerical investigations of S700 high strength steel CHS beam-columns after exposure to fire
title_fullStr Experiment and numerical investigations of S700 high strength steel CHS beam-columns after exposure to fire
title_full_unstemmed Experiment and numerical investigations of S700 high strength steel CHS beam-columns after exposure to fire
title_sort experiment and numerical investigations of s700 high strength steel chs beam-columns after exposure to fire
publisher Nanyang Technological University
publishDate 2021
url https://hdl.handle.net/10356/149409
_version_ 1701270450500272128