A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water
Iodinated contrast media (ICMs) are a class of X-ray contrast media worldwide utilized for radiographic procedures. Since they cannot be removed efficiently during water treatment, they can be found in surface and groundwater. In this work, a rapid and sensitive direct injection liquid chromatograph...
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2021
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/153426 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-153426 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1534262021-12-04T20:11:27Z A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water Lopez-Prieto, Israel J. Wu, Shimin Ji, Weikang Daniels, Kevin D. Snyder, Shane Allen Nanyang Environment and Water Research Institute Engineering::Environmental engineering::Water treatment Iodinated Contrast Media Direct Injection Iodinated contrast media (ICMs) are a class of X-ray contrast media worldwide utilized for radiographic procedures. Since they cannot be removed efficiently during water treatment, they can be found in surface and groundwater. In this work, a rapid and sensitive direct injection liquid chromatography-tandem (LC-MS/MS) method for the simultaneous analysis of seven ICMs media (iopamidol, ioxitalamic acid, diatrizoic acid, iothalamic acid, iohexol, iomeprol and iopromide) in complex aqueous matrices has been developed and validated. The MDLs for the analytes ranged from 0.7 to 21 ng L-1 in ultrapure water, and recoveries ranged from 86 to 100% in drinking water, 85-103% in groundwater and 84-105% in WWTP effluent. A stereo-isomer for iopromide was separated. This analytic method was applied to investigate the removal of target ICMs by low pressure ultra violet light (LPUV) advanced oxidation processes with three oxidants, hydrogen peroxide, free chlorine and monochloramine in groundwater. Results showed that the addition of oxidants did not enhance attenuation of ICMs, since fluence-based decay apparent rate constants were similar (KUV = 3.2 × 10-3, KUV-Cl2 = 3.6 × 10-3 and KUV-NH2 = 3.4 × 10-3 10-3 cm2 mJ-1). This yielded direct photolysis is the main mechanism to attenuate target ICMs. Accepted version 2021-12-01T06:44:09Z 2021-12-01T06:44:09Z 2020 Journal Article Lopez-Prieto, I. J., Wu, S., Ji, W., Daniels, K. D. & Snyder, S. A. (2020). A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water. Chemosphere, 243, 125311-. https://dx.doi.org/10.1016/j.chemosphere.2019.125311 0045-6535 https://hdl.handle.net/10356/153426 10.1016/j.chemosphere.2019.125311 31759215 2-s2.0-85075084480 243 125311 en Chemosphere © 2019 Elsevier Ltd. All rights reserved. This paper was published in Chemosphere and is made available with permission of Elsevier Ltd. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
Engineering::Environmental engineering::Water treatment Iodinated Contrast Media Direct Injection |
spellingShingle |
Engineering::Environmental engineering::Water treatment Iodinated Contrast Media Direct Injection Lopez-Prieto, Israel J. Wu, Shimin Ji, Weikang Daniels, Kevin D. Snyder, Shane Allen A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water |
description |
Iodinated contrast media (ICMs) are a class of X-ray contrast media worldwide utilized for radiographic procedures. Since they cannot be removed efficiently during water treatment, they can be found in surface and groundwater. In this work, a rapid and sensitive direct injection liquid chromatography-tandem (LC-MS/MS) method for the simultaneous analysis of seven ICMs media (iopamidol, ioxitalamic acid, diatrizoic acid, iothalamic acid, iohexol, iomeprol and iopromide) in complex aqueous matrices has been developed and validated. The MDLs for the analytes ranged from 0.7 to 21 ng L-1 in ultrapure water, and recoveries ranged from 86 to 100% in drinking water, 85-103% in groundwater and 84-105% in WWTP effluent. A stereo-isomer for iopromide was separated. This analytic method was applied to investigate the removal of target ICMs by low pressure ultra violet light (LPUV) advanced oxidation processes with three oxidants, hydrogen peroxide, free chlorine and monochloramine in groundwater. Results showed that the addition of oxidants did not enhance attenuation of ICMs, since fluence-based decay apparent rate constants were similar (KUV = 3.2 × 10-3, KUV-Cl2 = 3.6 × 10-3 and KUV-NH2 = 3.4 × 10-3 10-3 cm2 mJ-1). This yielded direct photolysis is the main mechanism to attenuate target ICMs. |
author2 |
Nanyang Environment and Water Research Institute |
author_facet |
Nanyang Environment and Water Research Institute Lopez-Prieto, Israel J. Wu, Shimin Ji, Weikang Daniels, Kevin D. Snyder, Shane Allen |
format |
Article |
author |
Lopez-Prieto, Israel J. Wu, Shimin Ji, Weikang Daniels, Kevin D. Snyder, Shane Allen |
author_sort |
Lopez-Prieto, Israel J. |
title |
A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water |
title_short |
A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water |
title_full |
A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water |
title_fullStr |
A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water |
title_full_unstemmed |
A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water |
title_sort |
direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (icms) removal in natural water |
publishDate |
2021 |
url |
https://hdl.handle.net/10356/153426 |
_version_ |
1718368091940847616 |