A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water

Iodinated contrast media (ICMs) are a class of X-ray contrast media worldwide utilized for radiographic procedures. Since they cannot be removed efficiently during water treatment, they can be found in surface and groundwater. In this work, a rapid and sensitive direct injection liquid chromatograph...

Full description

Saved in:
Bibliographic Details
Main Authors: Lopez-Prieto, Israel J., Wu, Shimin, Ji, Weikang, Daniels, Kevin D., Snyder, Shane Allen
Other Authors: Nanyang Environment and Water Research Institute
Format: Article
Language:English
Published: 2021
Subjects:
Online Access:https://hdl.handle.net/10356/153426
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-153426
record_format dspace
spelling sg-ntu-dr.10356-1534262021-12-04T20:11:27Z A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water Lopez-Prieto, Israel J. Wu, Shimin Ji, Weikang Daniels, Kevin D. Snyder, Shane Allen Nanyang Environment and Water Research Institute Engineering::Environmental engineering::Water treatment Iodinated Contrast Media Direct Injection Iodinated contrast media (ICMs) are a class of X-ray contrast media worldwide utilized for radiographic procedures. Since they cannot be removed efficiently during water treatment, they can be found in surface and groundwater. In this work, a rapid and sensitive direct injection liquid chromatography-tandem (LC-MS/MS) method for the simultaneous analysis of seven ICMs media (iopamidol, ioxitalamic acid, diatrizoic acid, iothalamic acid, iohexol, iomeprol and iopromide) in complex aqueous matrices has been developed and validated. The MDLs for the analytes ranged from 0.7 to 21 ng L-1 in ultrapure water, and recoveries ranged from 86 to 100% in drinking water, 85-103% in groundwater and 84-105% in WWTP effluent. A stereo-isomer for iopromide was separated. This analytic method was applied to investigate the removal of target ICMs by low pressure ultra violet light (LPUV) advanced oxidation processes with three oxidants, hydrogen peroxide, free chlorine and monochloramine in groundwater. Results showed that the addition of oxidants did not enhance attenuation of ICMs, since fluence-based decay apparent rate constants were similar (KUV = 3.2 × 10-3, KUV-Cl2 = 3.6 × 10-3 and KUV-NH2 = 3.4 × 10-3 10-3 cm2 mJ-1). This yielded direct photolysis is the main mechanism to attenuate target ICMs. Accepted version 2021-12-01T06:44:09Z 2021-12-01T06:44:09Z 2020 Journal Article Lopez-Prieto, I. J., Wu, S., Ji, W., Daniels, K. D. & Snyder, S. A. (2020). A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water. Chemosphere, 243, 125311-. https://dx.doi.org/10.1016/j.chemosphere.2019.125311 0045-6535 https://hdl.handle.net/10356/153426 10.1016/j.chemosphere.2019.125311 31759215 2-s2.0-85075084480 243 125311 en Chemosphere © 2019 Elsevier Ltd. All rights reserved. This paper was published in Chemosphere and is made available with permission of Elsevier Ltd. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Environmental engineering::Water treatment
Iodinated Contrast Media
Direct Injection
spellingShingle Engineering::Environmental engineering::Water treatment
Iodinated Contrast Media
Direct Injection
Lopez-Prieto, Israel J.
Wu, Shimin
Ji, Weikang
Daniels, Kevin D.
Snyder, Shane Allen
A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water
description Iodinated contrast media (ICMs) are a class of X-ray contrast media worldwide utilized for radiographic procedures. Since they cannot be removed efficiently during water treatment, they can be found in surface and groundwater. In this work, a rapid and sensitive direct injection liquid chromatography-tandem (LC-MS/MS) method for the simultaneous analysis of seven ICMs media (iopamidol, ioxitalamic acid, diatrizoic acid, iothalamic acid, iohexol, iomeprol and iopromide) in complex aqueous matrices has been developed and validated. The MDLs for the analytes ranged from 0.7 to 21 ng L-1 in ultrapure water, and recoveries ranged from 86 to 100% in drinking water, 85-103% in groundwater and 84-105% in WWTP effluent. A stereo-isomer for iopromide was separated. This analytic method was applied to investigate the removal of target ICMs by low pressure ultra violet light (LPUV) advanced oxidation processes with three oxidants, hydrogen peroxide, free chlorine and monochloramine in groundwater. Results showed that the addition of oxidants did not enhance attenuation of ICMs, since fluence-based decay apparent rate constants were similar (KUV = 3.2 × 10-3, KUV-Cl2 = 3.6 × 10-3 and KUV-NH2 = 3.4 × 10-3 10-3 cm2 mJ-1). This yielded direct photolysis is the main mechanism to attenuate target ICMs.
author2 Nanyang Environment and Water Research Institute
author_facet Nanyang Environment and Water Research Institute
Lopez-Prieto, Israel J.
Wu, Shimin
Ji, Weikang
Daniels, Kevin D.
Snyder, Shane Allen
format Article
author Lopez-Prieto, Israel J.
Wu, Shimin
Ji, Weikang
Daniels, Kevin D.
Snyder, Shane Allen
author_sort Lopez-Prieto, Israel J.
title A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water
title_short A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water
title_full A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water
title_fullStr A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water
title_full_unstemmed A direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (ICMs) removal in natural water
title_sort direct injection liquid chromatography tandem mass spectrometry method for the kinetic study on iodinated contrast media (icms) removal in natural water
publishDate 2021
url https://hdl.handle.net/10356/153426
_version_ 1718368091940847616