Model based reduction of ultrasound reverberation artifacts

This study is to address the low image quality problem of medical ultrasound imaging in terms of reverberation artifacts, and subsequently to propose a model as a basis for the reduction of such artifacts. Reverberation caused by reflections of ultrasound signal between two interfaces gives rise to...

Full description

Saved in:
Bibliographic Details
Main Author: Wang, Jing.
Other Authors: Zhang Cishen
Format: Final Year Project
Language:English
Published: 2009
Subjects:
Online Access:http://hdl.handle.net/10356/15803
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-15803
record_format dspace
spelling sg-ntu-dr.10356-158032023-07-07T17:06:20Z Model based reduction of ultrasound reverberation artifacts Wang, Jing. Zhang Cishen School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Medical electronics This study is to address the low image quality problem of medical ultrasound imaging in terms of reverberation artifacts, and subsequently to propose a model as a basis for the reduction of such artifacts. Reverberation caused by reflections of ultrasound signal between two interfaces gives rise to multiple copies of the anatomy at the interface, significantly degrading image quality and accuracy. This study is an extension of the method for the identification of reverberation echoes in multilayered media, based on the comparison of their power spectra (estimated via Fast Fourier Transform) through a least mean square approach, and linear combination of the temporal relationship (based on time-of-flight). To provide a systematic approach, the author investigated the nature of reverberation artifacts formation, and proposed a mathematical model to express reverberations phenomenon concisely and accurately. In addition, the algorithm of this method was developed including time-of-flight acquisition and Linear Combination formation. Last but not least, this analysis was extended to 2D data to generate reverberation-free images which will be more beneficial for clinical diagnosis. Through the qualitative and quantitative assessments of the performance, the objectives of reverberation reduction and improvement of ultrasound imaging quality to obtain accurate diagnosis information were successfully achieved. Bachelor of Engineering 2009-05-15T07:07:42Z 2009-05-15T07:07:42Z 2009 2009 Final Year Project (FYP) http://hdl.handle.net/10356/15803 en Nanyang Technological University 108 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Medical electronics
spellingShingle DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Medical electronics
Wang, Jing.
Model based reduction of ultrasound reverberation artifacts
description This study is to address the low image quality problem of medical ultrasound imaging in terms of reverberation artifacts, and subsequently to propose a model as a basis for the reduction of such artifacts. Reverberation caused by reflections of ultrasound signal between two interfaces gives rise to multiple copies of the anatomy at the interface, significantly degrading image quality and accuracy. This study is an extension of the method for the identification of reverberation echoes in multilayered media, based on the comparison of their power spectra (estimated via Fast Fourier Transform) through a least mean square approach, and linear combination of the temporal relationship (based on time-of-flight). To provide a systematic approach, the author investigated the nature of reverberation artifacts formation, and proposed a mathematical model to express reverberations phenomenon concisely and accurately. In addition, the algorithm of this method was developed including time-of-flight acquisition and Linear Combination formation. Last but not least, this analysis was extended to 2D data to generate reverberation-free images which will be more beneficial for clinical diagnosis. Through the qualitative and quantitative assessments of the performance, the objectives of reverberation reduction and improvement of ultrasound imaging quality to obtain accurate diagnosis information were successfully achieved.
author2 Zhang Cishen
author_facet Zhang Cishen
Wang, Jing.
format Final Year Project
author Wang, Jing.
author_sort Wang, Jing.
title Model based reduction of ultrasound reverberation artifacts
title_short Model based reduction of ultrasound reverberation artifacts
title_full Model based reduction of ultrasound reverberation artifacts
title_fullStr Model based reduction of ultrasound reverberation artifacts
title_full_unstemmed Model based reduction of ultrasound reverberation artifacts
title_sort model based reduction of ultrasound reverberation artifacts
publishDate 2009
url http://hdl.handle.net/10356/15803
_version_ 1772827479892819968