Coordination control of hybrid AC/DC building microgrid

Hybrid AC/DC microgrids are an appealing choice for future building networks due to benefits such as flexibility, high efficiency, low cost of loads, and green sources. The construction of a building hybrid AC/DC microgrid differs from that of a typical microgrid. In addition, when the typical load...

Full description

Saved in:
Bibliographic Details
Main Author: Lang, Baizhuo
Other Authors: Wang Peng
Format: Thesis-Master by Coursework
Language:English
Published: Nanyang Technological University 2022
Subjects:
Online Access:https://hdl.handle.net/10356/158371
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-158371
record_format dspace
spelling sg-ntu-dr.10356-1583712023-07-04T17:52:59Z Coordination control of hybrid AC/DC building microgrid Lang, Baizhuo Wang Peng School of Electrical and Electronic Engineering epwang@ntu.edu.sg Engineering::Electrical and electronic engineering Hybrid AC/DC microgrids are an appealing choice for future building networks due to benefits such as flexibility, high efficiency, low cost of loads, and green sources. The construction of a building hybrid AC/DC microgrid differs from that of a typical microgrid. In addition, when the typical load in the building microgrid undergoes a step change, it may affect the transient stability and power quality of the system. When the MVS (Main Voltage Source) in the subgrid is disconnected, it will cause voltage sag, frequency variation, and even affect the balance of energy transmission. If the voltage and frequency cannot be stabilized in a short period of time, it will cause the decline of power quality and even the transient imbalance of the power system. Aiming at the above problems, this dissertation proposes a building hybrid AC/DC microgrid architecture that uses renewable energy as MVS and includes the typical load of the building microgrid. It also uses the coordination control approach to the hybrid building microgrid and a uniform control for bidirectional ac/dc interlinking converter (BIC), which includes both centralized and decentralized control. The control method can ensure system stability and maintain power balance when the building microgrid has a sudden load change and MVS disconnection. It has the capacity to transmit power via BIC in order to preserve stability and achieve fast and smooth changeover between modes. The voltage and frequency are also adjusted to swiftly restore to the permitted range, resolving the voltage stability and power quality issues created by the building hybrid microgrid's voltage sag. This dissertation also includes a simulation verification of the control approach. Under specific scenarios such as step changes in building microgrid load and MVS disconnection, voltage and frequency can also recover to a safe level rapidly and remain relatively constant. Voltage sag-related voltage stability and power quality issues can be effectively controlled. It's worth noting that this dissertation also verifies the efficacy of centralized control. When the system is operating regularly, BIC can transmit the appropriate power flow. What’s more, BIC can still receive the instructions from the energy management system (EMS) and transmit the prescribed power when the load has a step change. In certain instances, such as MVS disconnection, the system will prioritize guaranteeing stability, particularly for voltage and frequency parameters. This dissertation proposes a possible solution to the transient voltage stability and power quality challenges of building hybrid AC/DC microgrids. Master of Science (Power Engineering) 2022-05-25T02:20:33Z 2022-05-25T02:20:33Z 2022 Thesis-Master by Coursework Lang, B. (2022). Coordination control of hybrid AC/DC building microgrid. Master's thesis, Nanyang Technological University, Singapore. https://hdl.handle.net/10356/158371 https://hdl.handle.net/10356/158371 en application/pdf Nanyang Technological University
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Electrical and electronic engineering
spellingShingle Engineering::Electrical and electronic engineering
Lang, Baizhuo
Coordination control of hybrid AC/DC building microgrid
description Hybrid AC/DC microgrids are an appealing choice for future building networks due to benefits such as flexibility, high efficiency, low cost of loads, and green sources. The construction of a building hybrid AC/DC microgrid differs from that of a typical microgrid. In addition, when the typical load in the building microgrid undergoes a step change, it may affect the transient stability and power quality of the system. When the MVS (Main Voltage Source) in the subgrid is disconnected, it will cause voltage sag, frequency variation, and even affect the balance of energy transmission. If the voltage and frequency cannot be stabilized in a short period of time, it will cause the decline of power quality and even the transient imbalance of the power system. Aiming at the above problems, this dissertation proposes a building hybrid AC/DC microgrid architecture that uses renewable energy as MVS and includes the typical load of the building microgrid. It also uses the coordination control approach to the hybrid building microgrid and a uniform control for bidirectional ac/dc interlinking converter (BIC), which includes both centralized and decentralized control. The control method can ensure system stability and maintain power balance when the building microgrid has a sudden load change and MVS disconnection. It has the capacity to transmit power via BIC in order to preserve stability and achieve fast and smooth changeover between modes. The voltage and frequency are also adjusted to swiftly restore to the permitted range, resolving the voltage stability and power quality issues created by the building hybrid microgrid's voltage sag. This dissertation also includes a simulation verification of the control approach. Under specific scenarios such as step changes in building microgrid load and MVS disconnection, voltage and frequency can also recover to a safe level rapidly and remain relatively constant. Voltage sag-related voltage stability and power quality issues can be effectively controlled. It's worth noting that this dissertation also verifies the efficacy of centralized control. When the system is operating regularly, BIC can transmit the appropriate power flow. What’s more, BIC can still receive the instructions from the energy management system (EMS) and transmit the prescribed power when the load has a step change. In certain instances, such as MVS disconnection, the system will prioritize guaranteeing stability, particularly for voltage and frequency parameters. This dissertation proposes a possible solution to the transient voltage stability and power quality challenges of building hybrid AC/DC microgrids.
author2 Wang Peng
author_facet Wang Peng
Lang, Baizhuo
format Thesis-Master by Coursework
author Lang, Baizhuo
author_sort Lang, Baizhuo
title Coordination control of hybrid AC/DC building microgrid
title_short Coordination control of hybrid AC/DC building microgrid
title_full Coordination control of hybrid AC/DC building microgrid
title_fullStr Coordination control of hybrid AC/DC building microgrid
title_full_unstemmed Coordination control of hybrid AC/DC building microgrid
title_sort coordination control of hybrid ac/dc building microgrid
publisher Nanyang Technological University
publishDate 2022
url https://hdl.handle.net/10356/158371
_version_ 1772826611990659072