Blood cell fractionation using spiral inertial microfluidics

White blood cells (WBCs) are integral in host immune system to maintain hemostasis and defense against foreign entities (e.g. virus) and diseases. Neutrophils are the most abundant WBCs in humans for innate immunity. Complete blood or WBCs/neutrophil counts are often measured in blood tests using he...

Full description

Saved in:
Bibliographic Details
Main Author: Pui, Daryl Oui Leung
Other Authors: Hou Han Wei
Format: Final Year Project
Language:English
Published: Nanyang Technological University 2022
Subjects:
Online Access:https://hdl.handle.net/10356/158761
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-158761
record_format dspace
spelling sg-ntu-dr.10356-1587612023-03-04T20:13:59Z Blood cell fractionation using spiral inertial microfluidics Pui, Daryl Oui Leung Hou Han Wei School of Mechanical and Aerospace Engineering hwhou@ntu.edu.sg Engineering::Bioengineering Engineering::Mechanical engineering White blood cells (WBCs) are integral in host immune system to maintain hemostasis and defense against foreign entities (e.g. virus) and diseases. Neutrophils are the most abundant WBCs in humans for innate immunity. Complete blood or WBCs/neutrophil counts are often measured in blood tests using hematoanalzyer but these results do not provide additional information such as cell functions which are indicative of inflammation. A major bottleneck is the high red blood cells (RBCs) background which hinder the isolation of WBCs/neutrophils for functional assays. Traditional methods require centrifugations or antibody binding which are time-consuming and may affect activate cells if not done properly. Hence there is a critical need to develop novel WBC and neutrophil isolation methods for point-of-care testing. In this thesis, we report a microfluidics technology termed as Dean Flow Fractionation (DFF) for direct and label-free isolation of WBCs and neutrophils from blood. A comparative study was first performed using 2 DFF microfluidic devices (of different channel heights and outlet configurations) to characterize sample to buffer flow rate ratios and blood dilution factor. Our results showed that DFF can achieve efficient WBCs (> 80%) and neutrophils (>85%) with ~99% depletion of RBCs using different channel designs. Taken together, the DFF is highly useful for label-free and rapid WBCs separation, and users can select the DFF chips to operate depending on the target cells of interests. We envision that DFF can be readily coupled with other microfluidic detection or functional assays in an integrated platform for point-of-care diagnostics. Bachelor of Engineering (Mechanical Engineering) 2022-06-06T04:17:21Z 2022-06-06T04:17:21Z 2022 Final Year Project (FYP) Pui, D. O. L. (2022). Blood cell fractionation using spiral inertial microfluidics. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/158761 https://hdl.handle.net/10356/158761 en A077 application/pdf Nanyang Technological University
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Bioengineering
Engineering::Mechanical engineering
spellingShingle Engineering::Bioengineering
Engineering::Mechanical engineering
Pui, Daryl Oui Leung
Blood cell fractionation using spiral inertial microfluidics
description White blood cells (WBCs) are integral in host immune system to maintain hemostasis and defense against foreign entities (e.g. virus) and diseases. Neutrophils are the most abundant WBCs in humans for innate immunity. Complete blood or WBCs/neutrophil counts are often measured in blood tests using hematoanalzyer but these results do not provide additional information such as cell functions which are indicative of inflammation. A major bottleneck is the high red blood cells (RBCs) background which hinder the isolation of WBCs/neutrophils for functional assays. Traditional methods require centrifugations or antibody binding which are time-consuming and may affect activate cells if not done properly. Hence there is a critical need to develop novel WBC and neutrophil isolation methods for point-of-care testing. In this thesis, we report a microfluidics technology termed as Dean Flow Fractionation (DFF) for direct and label-free isolation of WBCs and neutrophils from blood. A comparative study was first performed using 2 DFF microfluidic devices (of different channel heights and outlet configurations) to characterize sample to buffer flow rate ratios and blood dilution factor. Our results showed that DFF can achieve efficient WBCs (> 80%) and neutrophils (>85%) with ~99% depletion of RBCs using different channel designs. Taken together, the DFF is highly useful for label-free and rapid WBCs separation, and users can select the DFF chips to operate depending on the target cells of interests. We envision that DFF can be readily coupled with other microfluidic detection or functional assays in an integrated platform for point-of-care diagnostics.
author2 Hou Han Wei
author_facet Hou Han Wei
Pui, Daryl Oui Leung
format Final Year Project
author Pui, Daryl Oui Leung
author_sort Pui, Daryl Oui Leung
title Blood cell fractionation using spiral inertial microfluidics
title_short Blood cell fractionation using spiral inertial microfluidics
title_full Blood cell fractionation using spiral inertial microfluidics
title_fullStr Blood cell fractionation using spiral inertial microfluidics
title_full_unstemmed Blood cell fractionation using spiral inertial microfluidics
title_sort blood cell fractionation using spiral inertial microfluidics
publisher Nanyang Technological University
publishDate 2022
url https://hdl.handle.net/10356/158761
_version_ 1759855065793822720