Lyapunov-based large-signal control of three-phase stand-alone inverters with inherent dual control loops and load disturbance adaptivity

In this article, existed Lyapunov-based control methods for stand-alone inverters either have a single control loop accompanied with steady-state errors or dual control loops at the sacrifice of negative definiteness of the derivative of the Lyapunov function. Besides, load-current sensors or observ...

Full description

Saved in:
Bibliographic Details
Main Authors: He, Jinsong, Zhang, Xin, Ma, Hao, Cai, Chunwei
Other Authors: School of Electrical and Electronic Engineering
Format: Article
Language:English
Published: 2022
Subjects:
Online Access:https://hdl.handle.net/10356/160150
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-160150
record_format dspace
spelling sg-ntu-dr.10356-1601502022-07-13T08:18:47Z Lyapunov-based large-signal control of three-phase stand-alone inverters with inherent dual control loops and load disturbance adaptivity He, Jinsong Zhang, Xin Ma, Hao Cai, Chunwei School of Electrical and Electronic Engineering Engineering::Electrical and electronic engineering Large-Signal Stability Lyapunov In this article, existed Lyapunov-based control methods for stand-alone inverters either have a single control loop accompanied with steady-state errors or dual control loops at the sacrifice of negative definiteness of the derivative of the Lyapunov function. Besides, load-current sensors or observers are indispensable in these methods. Proposed Lyapunov-based control inherently has dual control loops that can rigorously guarantee the global large-signal stability of the system. Meanwhile, load disturbance is suppressed adaptively without any load-current sensors or observers. Stability analysis proves that the proposed method is valid both for a linear and nonlinear load. The proposed approach complies with the internal model principle, leading to the minimized steady-state error. An adaptive weighted Lyapunov function (V) is proposed to derive the dual-loop control law and adaptive law. The closed-loop system is inherently d-q decoupled. Three controller gains are tuned quantitatively via explicit formulas based on pole-placement strategy. Simulation and experimental results demonstrate that the proposed method has good steady-state and dynamic performance with great robustness against the parametric mismatch. 2022-07-13T08:18:47Z 2022-07-13T08:18:47Z 2020 Journal Article He, J., Zhang, X., Ma, H. & Cai, C. (2020). Lyapunov-based large-signal control of three-phase stand-alone inverters with inherent dual control loops and load disturbance adaptivity. IEEE Transactions On Industrial Electronics, 68(9), 8391-8401. https://dx.doi.org/10.1109/TIE.2020.3013774 0278-0046 https://hdl.handle.net/10356/160150 10.1109/TIE.2020.3013774 2-s2.0-85112313028 9 68 8391 8401 en IEEE Transactions on Industrial Electronics © 2020 IEEE. All rights reserved.
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Electrical and electronic engineering
Large-Signal Stability
Lyapunov
spellingShingle Engineering::Electrical and electronic engineering
Large-Signal Stability
Lyapunov
He, Jinsong
Zhang, Xin
Ma, Hao
Cai, Chunwei
Lyapunov-based large-signal control of three-phase stand-alone inverters with inherent dual control loops and load disturbance adaptivity
description In this article, existed Lyapunov-based control methods for stand-alone inverters either have a single control loop accompanied with steady-state errors or dual control loops at the sacrifice of negative definiteness of the derivative of the Lyapunov function. Besides, load-current sensors or observers are indispensable in these methods. Proposed Lyapunov-based control inherently has dual control loops that can rigorously guarantee the global large-signal stability of the system. Meanwhile, load disturbance is suppressed adaptively without any load-current sensors or observers. Stability analysis proves that the proposed method is valid both for a linear and nonlinear load. The proposed approach complies with the internal model principle, leading to the minimized steady-state error. An adaptive weighted Lyapunov function (V) is proposed to derive the dual-loop control law and adaptive law. The closed-loop system is inherently d-q decoupled. Three controller gains are tuned quantitatively via explicit formulas based on pole-placement strategy. Simulation and experimental results demonstrate that the proposed method has good steady-state and dynamic performance with great robustness against the parametric mismatch.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
He, Jinsong
Zhang, Xin
Ma, Hao
Cai, Chunwei
format Article
author He, Jinsong
Zhang, Xin
Ma, Hao
Cai, Chunwei
author_sort He, Jinsong
title Lyapunov-based large-signal control of three-phase stand-alone inverters with inherent dual control loops and load disturbance adaptivity
title_short Lyapunov-based large-signal control of three-phase stand-alone inverters with inherent dual control loops and load disturbance adaptivity
title_full Lyapunov-based large-signal control of three-phase stand-alone inverters with inherent dual control loops and load disturbance adaptivity
title_fullStr Lyapunov-based large-signal control of three-phase stand-alone inverters with inherent dual control loops and load disturbance adaptivity
title_full_unstemmed Lyapunov-based large-signal control of three-phase stand-alone inverters with inherent dual control loops and load disturbance adaptivity
title_sort lyapunov-based large-signal control of three-phase stand-alone inverters with inherent dual control loops and load disturbance adaptivity
publishDate 2022
url https://hdl.handle.net/10356/160150
_version_ 1738844891513880576