Continuous, high-throughput production of artemisinin-loaded supramolecular cochleates using simple off-the-shelf flow focusing device
Lipid cochleates are gaining increasing interest as drug-carriers. However, their preparation relies on conventional batch processes that are complex, time consuming and lack batch-to-batch reproducibility; presenting a bottleneck for clinical translation. We report an efficient continuous preparati...
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2022
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/161083 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-161083 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1610832022-08-15T04:31:55Z Continuous, high-throughput production of artemisinin-loaded supramolecular cochleates using simple off-the-shelf flow focusing device Shuddhodana Wong, Kathy Pooi Wen Judeh, Zaher School of Chemical and Biomedical Engineering Engineering::Chemical engineering Lipids Cochleates Lipid cochleates are gaining increasing interest as drug-carriers. However, their preparation relies on conventional batch processes that are complex, time consuming and lack batch-to-batch reproducibility; presenting a bottleneck for clinical translation. We report an efficient continuous preparation process for artemisinin-loaded cochleates (ART-cochleates) using inexpensive off-the-shelf flow focusing device. By carefully controlling the flow focusing parameters, we showed along with the mechanism that, ART-cochleates of uniform and tuneable size (~180 nm in width and ~1030 nm in length) were obtained with low dispersity (0.18 in width and 0.27 in length), narrow size distribution and high reproducibility compared to the batch process. The device achieved high throughput of 11.5 g/day with ART encapsulation of 64.24 ± 2.5% and loading of 83.37 ± 3.68 mg ART/g of cochleates. Art-cochleates were non-toxic and showed sustained in-vitro release of ART with effective transepithelial permeability across intestinal Caco-2 monolayer (~60% and ~25% transport for pure ART and ART-cochleates, respectively) resulting in better in-vitro bioavailability. The off-the-shelf device is envisioned to be highly promising platform for continuous and high-throughput manufacturing of drug-loaded cochleates in a controlled and reproducible manner. It has potential to enable clinical translation of drug-loaded cochleates with predicable drug release, absorption and bioavailability. Nanyang Technological University We thank Nanyang Technological University, Singapore for financial help (RG 13/18). 2022-08-15T04:31:55Z 2022-08-15T04:31:55Z 2020 Journal Article Shuddhodana, Wong, K. P. W. & Judeh, Z. (2020). Continuous, high-throughput production of artemisinin-loaded supramolecular cochleates using simple off-the-shelf flow focusing device. Materials Science and Engineering: C, 108, 110410-. https://dx.doi.org/10.1016/j.msec.2019.110410 0928-4931 https://hdl.handle.net/10356/161083 10.1016/j.msec.2019.110410 31923944 2-s2.0-85074717221 108 110410 en RG 13/18 Materials Science and Engineering: C © 2019 Elsevier B.V. All rights reserved. |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
Engineering::Chemical engineering Lipids Cochleates |
spellingShingle |
Engineering::Chemical engineering Lipids Cochleates Shuddhodana Wong, Kathy Pooi Wen Judeh, Zaher Continuous, high-throughput production of artemisinin-loaded supramolecular cochleates using simple off-the-shelf flow focusing device |
description |
Lipid cochleates are gaining increasing interest as drug-carriers. However, their preparation relies on conventional batch processes that are complex, time consuming and lack batch-to-batch reproducibility; presenting a bottleneck for clinical translation. We report an efficient continuous preparation process for artemisinin-loaded cochleates (ART-cochleates) using inexpensive off-the-shelf flow focusing device. By carefully controlling the flow focusing parameters, we showed along with the mechanism that, ART-cochleates of uniform and tuneable size (~180 nm in width and ~1030 nm in length) were obtained with low dispersity (0.18 in width and 0.27 in length), narrow size distribution and high reproducibility compared to the batch process. The device achieved high throughput of 11.5 g/day with ART encapsulation of 64.24 ± 2.5% and loading of 83.37 ± 3.68 mg ART/g of cochleates. Art-cochleates were non-toxic and showed sustained in-vitro release of ART with effective transepithelial permeability across intestinal Caco-2 monolayer (~60% and ~25% transport for pure ART and ART-cochleates, respectively) resulting in better in-vitro bioavailability. The off-the-shelf device is envisioned to be highly promising platform for continuous and high-throughput manufacturing of drug-loaded cochleates in a controlled and reproducible manner. It has potential to enable clinical translation of drug-loaded cochleates with predicable drug release, absorption and bioavailability. |
author2 |
School of Chemical and Biomedical Engineering |
author_facet |
School of Chemical and Biomedical Engineering Shuddhodana Wong, Kathy Pooi Wen Judeh, Zaher |
format |
Article |
author |
Shuddhodana Wong, Kathy Pooi Wen Judeh, Zaher |
author_sort |
Shuddhodana |
title |
Continuous, high-throughput production of artemisinin-loaded supramolecular cochleates using simple off-the-shelf flow focusing device |
title_short |
Continuous, high-throughput production of artemisinin-loaded supramolecular cochleates using simple off-the-shelf flow focusing device |
title_full |
Continuous, high-throughput production of artemisinin-loaded supramolecular cochleates using simple off-the-shelf flow focusing device |
title_fullStr |
Continuous, high-throughput production of artemisinin-loaded supramolecular cochleates using simple off-the-shelf flow focusing device |
title_full_unstemmed |
Continuous, high-throughput production of artemisinin-loaded supramolecular cochleates using simple off-the-shelf flow focusing device |
title_sort |
continuous, high-throughput production of artemisinin-loaded supramolecular cochleates using simple off-the-shelf flow focusing device |
publishDate |
2022 |
url |
https://hdl.handle.net/10356/161083 |
_version_ |
1743119611074707456 |