Experimental investigation of CIP and PC beam-to-CECFST column joints with simple connection details under lateral cyclic loading

Due to the excellent structural performance of Concrete-encased concrete-filled steel tube (CECFST) columns, they have been applied in real practice for several years. In addition, precast technology can be utilised in the construction of CECFST composite structures to further improve productivity....

Full description

Saved in:
Bibliographic Details
Main Authors: Ma, You-Xin, Tan, Kang Hai
Other Authors: School of Civil and Environmental Engineering
Format: Article
Language:English
Published: 2022
Subjects:
Online Access:https://hdl.handle.net/10356/161840
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-161840
record_format dspace
spelling sg-ntu-dr.10356-1618402022-09-21T05:42:02Z Experimental investigation of CIP and PC beam-to-CECFST column joints with simple connection details under lateral cyclic loading Ma, You-Xin Tan, Kang Hai School of Civil and Environmental Engineering Engineering::Civil engineering Shear Resistance Contribution CECFST Columns Due to the excellent structural performance of Concrete-encased concrete-filled steel tube (CECFST) columns, they have been applied in real practice for several years. In addition, precast technology can be utilised in the construction of CECFST composite structures to further improve productivity. To investigate the behaviour of precast concrete (PC) and cast-in-place (CIP) beam-to-CECFST column joints, a total of 6 joint specimens, including 4 PC and 2 CIP specimens, were thus experimentally studied under lateral cyclic loading. In this paper, the main studied parameters included connection details, construction methods and existence of column axial load. The ultimate strength, failure mode, crack patterns and hysteretic performance of each specimen were analysed in detail. According to the test results, the performance of CIP and PC joint specimens were discussed in the aspect of energy dissipation, ductility and damping coefficients, strength and rigidity degradations. It was found that the PC specimens exhibited comparable cyclic behaviour to the CIP specimens in regards to the maximum strength, hysteretic performance and failure mode. Moreover, based on the measured shear strains, contributions of joint shear resistance from steel tube, inner and outer concrete were quantitatively investigated. Thereafter, the development of shear stress in the outer concrete was compared with the nominal concrete shear strengths from American and European design provisions. The authors gratefully acknowledge the funding entitled as “The behaviour and design of innovative composite concrete-steel structural system” provided by Jurong Town Corporation in Singapore. 2022-09-21T05:42:02Z 2022-09-21T05:42:02Z 2022 Journal Article Ma, Y. & Tan, K. H. (2022). Experimental investigation of CIP and PC beam-to-CECFST column joints with simple connection details under lateral cyclic loading. Engineering Structures, 265, 114460-. https://dx.doi.org/10.1016/j.engstruct.2022.114460 0141-0296 https://hdl.handle.net/10356/161840 10.1016/j.engstruct.2022.114460 2-s2.0-85131835422 265 114460 en Engineering Structures © 2022 Elsevier Ltd. All rights reserved.
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Civil engineering
Shear Resistance Contribution
CECFST Columns
spellingShingle Engineering::Civil engineering
Shear Resistance Contribution
CECFST Columns
Ma, You-Xin
Tan, Kang Hai
Experimental investigation of CIP and PC beam-to-CECFST column joints with simple connection details under lateral cyclic loading
description Due to the excellent structural performance of Concrete-encased concrete-filled steel tube (CECFST) columns, they have been applied in real practice for several years. In addition, precast technology can be utilised in the construction of CECFST composite structures to further improve productivity. To investigate the behaviour of precast concrete (PC) and cast-in-place (CIP) beam-to-CECFST column joints, a total of 6 joint specimens, including 4 PC and 2 CIP specimens, were thus experimentally studied under lateral cyclic loading. In this paper, the main studied parameters included connection details, construction methods and existence of column axial load. The ultimate strength, failure mode, crack patterns and hysteretic performance of each specimen were analysed in detail. According to the test results, the performance of CIP and PC joint specimens were discussed in the aspect of energy dissipation, ductility and damping coefficients, strength and rigidity degradations. It was found that the PC specimens exhibited comparable cyclic behaviour to the CIP specimens in regards to the maximum strength, hysteretic performance and failure mode. Moreover, based on the measured shear strains, contributions of joint shear resistance from steel tube, inner and outer concrete were quantitatively investigated. Thereafter, the development of shear stress in the outer concrete was compared with the nominal concrete shear strengths from American and European design provisions.
author2 School of Civil and Environmental Engineering
author_facet School of Civil and Environmental Engineering
Ma, You-Xin
Tan, Kang Hai
format Article
author Ma, You-Xin
Tan, Kang Hai
author_sort Ma, You-Xin
title Experimental investigation of CIP and PC beam-to-CECFST column joints with simple connection details under lateral cyclic loading
title_short Experimental investigation of CIP and PC beam-to-CECFST column joints with simple connection details under lateral cyclic loading
title_full Experimental investigation of CIP and PC beam-to-CECFST column joints with simple connection details under lateral cyclic loading
title_fullStr Experimental investigation of CIP and PC beam-to-CECFST column joints with simple connection details under lateral cyclic loading
title_full_unstemmed Experimental investigation of CIP and PC beam-to-CECFST column joints with simple connection details under lateral cyclic loading
title_sort experimental investigation of cip and pc beam-to-cecfst column joints with simple connection details under lateral cyclic loading
publishDate 2022
url https://hdl.handle.net/10356/161840
_version_ 1745574616342986752