Concrete-filled high strength steel tube stub columns after exposure to fire: testing, numerical modelling and design

This paper reports experimental and numerical investigations into the structural behaviour and residual capacity of concrete-filled high strength steel tube (CFHST) stub columns after exposure to fire. The experimental investigation was conducted on twelve square CFHST stub column specimens after ex...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhong, Yukai, Zhao, Ou
Other Authors: School of Civil and Environmental Engineering
Format: Article
Language:English
Published: 2022
Subjects:
Online Access:https://hdl.handle.net/10356/161917
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-161917
record_format dspace
spelling sg-ntu-dr.10356-1619172022-09-26T05:36:42Z Concrete-filled high strength steel tube stub columns after exposure to fire: testing, numerical modelling and design Zhong, Yukai Zhao, Ou School of Civil and Environmental Engineering Engineering::Civil engineering Compression Tests CFHST Stub Columns This paper reports experimental and numerical investigations into the structural behaviour and residual capacity of concrete-filled high strength steel tube (CFHST) stub columns after exposure to fire. The experimental investigation was conducted on twelve square CFHST stub column specimens after exposure to the ISO-834 standard fire for 15 min, 30 min and 45 min and four reference specimens at ambient temperature. The test results, including failure loads, load–end shortening curves, initial compressive stiffnesses and failure modes, were fully reported and discussed. A numerical investigation was subsequently conducted, where thermal and mechanical finite element models were developed and validated against the test results, and afterwards used to performed parametric studies to generate further numerical data over a wide range of cross-section dimensions. Owing to the absence of design codes for composite structures after exposure to fire, the relevant ambient temperature design rules, as set out in European code, American specification and Australian/New Zealand standard, were evaluated, using post-fire material properties, for their applicability to post-fire CFHST stub columns, based on the test and numerical data. The evaluation results revealed that all the three design codes generally yield accurate failure load predictions for CFHST stub columns after exposure to fire. Ministry of Education (MOE) The present research work is financially supported by Singapore Ministry of Education Academic Research Fund (AcRF) Tier 1 Grant (Project Award Number: RG142/20). 2022-09-26T05:36:42Z 2022-09-26T05:36:42Z 2022 Journal Article Zhong, Y. & Zhao, O. (2022). Concrete-filled high strength steel tube stub columns after exposure to fire: testing, numerical modelling and design. Thin-Walled Structures, 177, 109428-. https://dx.doi.org/10.1016/j.tws.2022.109428 0263-8231 https://hdl.handle.net/10356/161917 10.1016/j.tws.2022.109428 2-s2.0-85131461285 177 109428 en RG142/20 Thin-Walled Structures © 2022 Elsevier Ltd. All rights reserved.
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Civil engineering
Compression Tests
CFHST Stub Columns
spellingShingle Engineering::Civil engineering
Compression Tests
CFHST Stub Columns
Zhong, Yukai
Zhao, Ou
Concrete-filled high strength steel tube stub columns after exposure to fire: testing, numerical modelling and design
description This paper reports experimental and numerical investigations into the structural behaviour and residual capacity of concrete-filled high strength steel tube (CFHST) stub columns after exposure to fire. The experimental investigation was conducted on twelve square CFHST stub column specimens after exposure to the ISO-834 standard fire for 15 min, 30 min and 45 min and four reference specimens at ambient temperature. The test results, including failure loads, load–end shortening curves, initial compressive stiffnesses and failure modes, were fully reported and discussed. A numerical investigation was subsequently conducted, where thermal and mechanical finite element models were developed and validated against the test results, and afterwards used to performed parametric studies to generate further numerical data over a wide range of cross-section dimensions. Owing to the absence of design codes for composite structures after exposure to fire, the relevant ambient temperature design rules, as set out in European code, American specification and Australian/New Zealand standard, were evaluated, using post-fire material properties, for their applicability to post-fire CFHST stub columns, based on the test and numerical data. The evaluation results revealed that all the three design codes generally yield accurate failure load predictions for CFHST stub columns after exposure to fire.
author2 School of Civil and Environmental Engineering
author_facet School of Civil and Environmental Engineering
Zhong, Yukai
Zhao, Ou
format Article
author Zhong, Yukai
Zhao, Ou
author_sort Zhong, Yukai
title Concrete-filled high strength steel tube stub columns after exposure to fire: testing, numerical modelling and design
title_short Concrete-filled high strength steel tube stub columns after exposure to fire: testing, numerical modelling and design
title_full Concrete-filled high strength steel tube stub columns after exposure to fire: testing, numerical modelling and design
title_fullStr Concrete-filled high strength steel tube stub columns after exposure to fire: testing, numerical modelling and design
title_full_unstemmed Concrete-filled high strength steel tube stub columns after exposure to fire: testing, numerical modelling and design
title_sort concrete-filled high strength steel tube stub columns after exposure to fire: testing, numerical modelling and design
publishDate 2022
url https://hdl.handle.net/10356/161917
_version_ 1745574654760714240