Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
Air Conditioning and Mechanical Ventilation (ACMV) systems have been around for many years to provide cooling to many buildings around the world. However, due to the alarming rates of global warming, it is essential to develop new innovative ACMV technology to reduce the carbon emissions due to the...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
Nanyang Technological University
2022
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/163801 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-163801 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1638012023-07-07T19:33:02Z Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system Chia, Marcus Wen Jun Wang Youyi School of Electrical and Electronic Engineering EYYWANG@ntu.edu.sg Engineering::Electrical and electronic engineering::Electronic systems Air Conditioning and Mechanical Ventilation (ACMV) systems have been around for many years to provide cooling to many buildings around the world. However, due to the alarming rates of global warming, it is essential to develop new innovative ACMV technology to reduce the carbon emissions due to the electrical consumption of the ACMVs. This report is based on the Thermosiphon Beam’s Air Conditioning and Mechanical Ventilation (TB ACMV) system which is developed in a joint research program with the School of Electrical and Electronics Engineering (EEE) and Energy Research Institute at Nanyang Technological University (ERI@N). It aims to explain how the TB ACMV system differs from the conventional ACMV system like the VAV AHU systems. The TB ACMV system is very versatile in handling both sensible and latent heat loads by splitting it into two major components, the Dedicated Outdoor Air System (DOAS) and the Thermosiphon Beam (TB). It also works with a higher chilled water temperature than the conventional ACMV system, hence reducing the overall energy consumption. The TB ACMV system also aims to improve Indoor Air Quality (IAQ) as well as ensure the thermal comfort of the occupants. The report would elaborate on how the TB ACMV is being controlled and how it is able to meet the required space heat loads with varying external air conditions. Bachelor of Engineering (Electrical and Electronic Engineering) 2022-12-19T01:09:07Z 2022-12-19T01:09:07Z 2022 Final Year Project (FYP) Chia, M. W. J. (2022). Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/163801 https://hdl.handle.net/10356/163801 en A1208-212 application/pdf Nanyang Technological University |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
Engineering::Electrical and electronic engineering::Electronic systems |
spellingShingle |
Engineering::Electrical and electronic engineering::Electronic systems Chia, Marcus Wen Jun Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system |
description |
Air Conditioning and Mechanical Ventilation (ACMV) systems have been around for many years to provide cooling to many buildings around the world. However, due to the alarming rates of global warming, it is essential to develop new innovative ACMV technology to reduce the carbon emissions due to the electrical consumption of the ACMVs.
This report is based on the Thermosiphon Beam’s Air Conditioning and Mechanical Ventilation (TB ACMV) system which is developed in a joint research program with the School of Electrical and Electronics Engineering (EEE) and Energy Research Institute at Nanyang Technological University (ERI@N). It aims to explain how the TB ACMV system differs from the conventional ACMV system like the VAV AHU systems. The TB ACMV system is very versatile in handling both sensible and latent heat loads by splitting it into two major components, the Dedicated Outdoor Air System (DOAS) and the Thermosiphon Beam (TB). It also works with a higher chilled water temperature than the conventional ACMV system, hence reducing the overall energy consumption. The TB ACMV system also aims to improve Indoor Air Quality (IAQ) as well as ensure the thermal comfort of the occupants. The report would elaborate on how the TB ACMV is being controlled and how it is able to meet the required space heat loads with varying external air conditions. |
author2 |
Wang Youyi |
author_facet |
Wang Youyi Chia, Marcus Wen Jun |
format |
Final Year Project |
author |
Chia, Marcus Wen Jun |
author_sort |
Chia, Marcus Wen Jun |
title |
Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system |
title_short |
Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system |
title_full |
Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system |
title_fullStr |
Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system |
title_full_unstemmed |
Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system |
title_sort |
performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system |
publisher |
Nanyang Technological University |
publishDate |
2022 |
url |
https://hdl.handle.net/10356/163801 |
_version_ |
1772825339349696512 |