Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system

Air Conditioning and Mechanical Ventilation (ACMV) systems have been around for many years to provide cooling to many buildings around the world. However, due to the alarming rates of global warming, it is essential to develop new innovative ACMV technology to reduce the carbon emissions due to the...

Full description

Saved in:
Bibliographic Details
Main Author: Chia, Marcus Wen Jun
Other Authors: Wang Youyi
Format: Final Year Project
Language:English
Published: Nanyang Technological University 2022
Subjects:
Online Access:https://hdl.handle.net/10356/163801
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-163801
record_format dspace
spelling sg-ntu-dr.10356-1638012023-07-07T19:33:02Z Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system Chia, Marcus Wen Jun Wang Youyi School of Electrical and Electronic Engineering EYYWANG@ntu.edu.sg Engineering::Electrical and electronic engineering::Electronic systems Air Conditioning and Mechanical Ventilation (ACMV) systems have been around for many years to provide cooling to many buildings around the world. However, due to the alarming rates of global warming, it is essential to develop new innovative ACMV technology to reduce the carbon emissions due to the electrical consumption of the ACMVs. This report is based on the Thermosiphon Beam’s Air Conditioning and Mechanical Ventilation (TB ACMV) system which is developed in a joint research program with the School of Electrical and Electronics Engineering (EEE) and Energy Research Institute at Nanyang Technological University (ERI@N). It aims to explain how the TB ACMV system differs from the conventional ACMV system like the VAV AHU systems. The TB ACMV system is very versatile in handling both sensible and latent heat loads by splitting it into two major components, the Dedicated Outdoor Air System (DOAS) and the Thermosiphon Beam (TB). It also works with a higher chilled water temperature than the conventional ACMV system, hence reducing the overall energy consumption. The TB ACMV system also aims to improve Indoor Air Quality (IAQ) as well as ensure the thermal comfort of the occupants. The report would elaborate on how the TB ACMV is being controlled and how it is able to meet the required space heat loads with varying external air conditions. Bachelor of Engineering (Electrical and Electronic Engineering) 2022-12-19T01:09:07Z 2022-12-19T01:09:07Z 2022 Final Year Project (FYP) Chia, M. W. J. (2022). Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/163801 https://hdl.handle.net/10356/163801 en A1208-212 application/pdf Nanyang Technological University
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Electrical and electronic engineering::Electronic systems
spellingShingle Engineering::Electrical and electronic engineering::Electronic systems
Chia, Marcus Wen Jun
Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
description Air Conditioning and Mechanical Ventilation (ACMV) systems have been around for many years to provide cooling to many buildings around the world. However, due to the alarming rates of global warming, it is essential to develop new innovative ACMV technology to reduce the carbon emissions due to the electrical consumption of the ACMVs. This report is based on the Thermosiphon Beam’s Air Conditioning and Mechanical Ventilation (TB ACMV) system which is developed in a joint research program with the School of Electrical and Electronics Engineering (EEE) and Energy Research Institute at Nanyang Technological University (ERI@N). It aims to explain how the TB ACMV system differs from the conventional ACMV system like the VAV AHU systems. The TB ACMV system is very versatile in handling both sensible and latent heat loads by splitting it into two major components, the Dedicated Outdoor Air System (DOAS) and the Thermosiphon Beam (TB). It also works with a higher chilled water temperature than the conventional ACMV system, hence reducing the overall energy consumption. The TB ACMV system also aims to improve Indoor Air Quality (IAQ) as well as ensure the thermal comfort of the occupants. The report would elaborate on how the TB ACMV is being controlled and how it is able to meet the required space heat loads with varying external air conditions.
author2 Wang Youyi
author_facet Wang Youyi
Chia, Marcus Wen Jun
format Final Year Project
author Chia, Marcus Wen Jun
author_sort Chia, Marcus Wen Jun
title Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
title_short Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
title_full Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
title_fullStr Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
title_full_unstemmed Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
title_sort performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
publisher Nanyang Technological University
publishDate 2022
url https://hdl.handle.net/10356/163801
_version_ 1772825339349696512