Design and development of a mock circulation loop for blood pumps

Congestive heart failure is a condition where insufficient blood is circulated around the body resulting in poor perfusion and multiple organ failure. Just in America alone, heart failure accounts for approximately 250,000 deaths yearly. With the limited number of hearts available for transplant, pa...

Full description

Saved in:
Bibliographic Details
Main Author: Ou, Jianwen.
Other Authors: Lim Tau Meng
Format: Final Year Project
Language:English
Published: 2009
Subjects:
Online Access:http://hdl.handle.net/10356/16794
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-16794
record_format dspace
spelling sg-ntu-dr.10356-167942019-12-10T14:21:25Z Design and development of a mock circulation loop for blood pumps Ou, Jianwen. Lim Tau Meng School of Mechanical and Aerospace Engineering DRNTU::Engineering::Bioengineering Congestive heart failure is a condition where insufficient blood is circulated around the body resulting in poor perfusion and multiple organ failure. Just in America alone, heart failure accounts for approximately 250,000 deaths yearly. With the limited number of hearts available for transplant, patients must seek other alternative. However with the use of left ventricular assist device (LVAD), the patients’ life quality will improve. However before a LVAD can be implanted, they must first be tested in an experimental flow loop. These mock circulatory loop are use to set the standard for testing pump while varying the different hemodynamic parameters. The main objective is to design and make alteration to the mock circulatory loop to further improve it. Further modification has been done to the set up; a pulsating pump has been fabricated and added to the loop to replicate the function of a heart. The aim of the piston pump is to supply the mock circulatory loop a constant flow rate of 5 liters per minute and a differential pressure of 100mmHg to simulate as closely as possible the actual human physiologic system condition. In addition to that, a mock circulation loop was set up to test run the piston pump. The result showed that the current setting of the pump is powerful enough to meet the required flow and pressure. In further works, addition of materials and items to increase the complexity of the loop, usage of other fluid mediums to conduct the experiment and modification to certain parts can be carried out. Bachelor of Engineering (Mechanical Engineering) 2009-05-28T04:28:47Z 2009-05-28T04:28:47Z 2009 2009 Final Year Project (FYP) http://hdl.handle.net/10356/16794 en Nanyang Technological University 76 p. application/msword
institution Nanyang Technological University
building NTU Library
country Singapore
collection DR-NTU
language English
topic DRNTU::Engineering::Bioengineering
spellingShingle DRNTU::Engineering::Bioengineering
Ou, Jianwen.
Design and development of a mock circulation loop for blood pumps
description Congestive heart failure is a condition where insufficient blood is circulated around the body resulting in poor perfusion and multiple organ failure. Just in America alone, heart failure accounts for approximately 250,000 deaths yearly. With the limited number of hearts available for transplant, patients must seek other alternative. However with the use of left ventricular assist device (LVAD), the patients’ life quality will improve. However before a LVAD can be implanted, they must first be tested in an experimental flow loop. These mock circulatory loop are use to set the standard for testing pump while varying the different hemodynamic parameters. The main objective is to design and make alteration to the mock circulatory loop to further improve it. Further modification has been done to the set up; a pulsating pump has been fabricated and added to the loop to replicate the function of a heart. The aim of the piston pump is to supply the mock circulatory loop a constant flow rate of 5 liters per minute and a differential pressure of 100mmHg to simulate as closely as possible the actual human physiologic system condition. In addition to that, a mock circulation loop was set up to test run the piston pump. The result showed that the current setting of the pump is powerful enough to meet the required flow and pressure. In further works, addition of materials and items to increase the complexity of the loop, usage of other fluid mediums to conduct the experiment and modification to certain parts can be carried out.
author2 Lim Tau Meng
author_facet Lim Tau Meng
Ou, Jianwen.
format Final Year Project
author Ou, Jianwen.
author_sort Ou, Jianwen.
title Design and development of a mock circulation loop for blood pumps
title_short Design and development of a mock circulation loop for blood pumps
title_full Design and development of a mock circulation loop for blood pumps
title_fullStr Design and development of a mock circulation loop for blood pumps
title_full_unstemmed Design and development of a mock circulation loop for blood pumps
title_sort design and development of a mock circulation loop for blood pumps
publishDate 2009
url http://hdl.handle.net/10356/16794
_version_ 1681034042892353536