Artificial urinary biomarkers for early diagnosis of acute renal allograft rejection
Acute renal allograft rejection (ARAR) after kidney transplantation associated with reduced graft survival and eventual graft failure is poorly diagnosed in hospitals. Here, we report the development of Artificial bioMarker Probes (AMPros) for sensitive urinalysis of ARAR in murine models. AMPros sp...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2023
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/170998 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-170998 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1709982023-10-15T15:38:30Z Artificial urinary biomarkers for early diagnosis of acute renal allograft rejection Cheng, Penghui Wang, Rending He, Shasha Yan, Pengpeng Huang, Hongfeng Chen, Jianghua Shen, Jia Pu, Kanyi Lee Kong Chian School of Medicine (LKCMedicine) School of Chemistry, Chemical Engineering and Biotechnology Science::Medicine Acute Allograft Rejection Fluorescent Probes Acute renal allograft rejection (ARAR) after kidney transplantation associated with reduced graft survival and eventual graft failure is poorly diagnosed in hospitals. Here, we report the development of Artificial bioMarker Probes (AMPros) for sensitive urinalysis of ARAR in murine models. AMPros spontaneously go to the kidneys after systemic administration, specifically react with the prodromal immune biomarkers to activate their near-infrared fluorescence signals to report cell-mediated rejection, and efficiently undergo renal excretion into urine. Thus, AMPros enable convenient optical urinalysis that detects ARAR prior to histological manifestation of rejection, which is also earlier than current diagnostic methods measuring proinflammatory cytokines and peripheral blood lymphocyte mRNAs. Due to the high kidney specificity, AMPros-based urinalysis discriminates allograft rejection against other non-alloimmune specific diseases, which is unattainable by measurement of serological biomarkers. Such a noninvasive and sensitive urine test holds great promise in continuous monitoring of renal allograft conditions at low resource settings for timely clinical interventions. Ministry of Education (MOE) National Research Foundation (NRF) Submitted/Accepted version K.P. thanks Singapore National Research Foundation (NRF) (NRF-NRFI07-2021-0005), and Singapore Ministry of Education, Academic Research Fund Tier 1(2019-T1-002-045, RG125/19, RT05/20), Academic Research Fund Tier 2 (MOE-T2EP30220-0010; MOE-T2EP30221-0004), for the financial support. J.S. thanks the National Natural Science Foundation of China (81870510, 82070767 and 82070766) and the Science and Technology Department of Zhejiang Province (2019C03029). 2023-10-10T03:03:45Z 2023-10-10T03:03:45Z 2023 Journal Article Cheng, P., Wang, R., He, S., Yan, P., Huang, H., Chen, J., Shen, J. & Pu, K. (2023). Artificial urinary biomarkers for early diagnosis of acute renal allograft rejection. Angewandte Chemie International Edition, 62(39), e202306539-. https://dx.doi.org/10.1002/anie.202306539 1433-7851 https://hdl.handle.net/10356/170998 10.1002/anie.202306539 37431650 2-s2.0-85165434399 39 62 e202306539 en NRF-NRFI07-2021-0005 2019-T1-002-045, RG125/19,RT05/20 RG125/19 RT05/20 MOE-T2EP30220-0010 MOE-T2EP30221-0004 Angewandte Chemie International Edition © 2023 Wiley-VCHGmbH. All rights reserved. This article may be downloaded for personal use only. Any other use requires prior permission of the copyright holder. The Version of Record is available online at http://doi.org/10.1002/anie.202306539. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
Science::Medicine Acute Allograft Rejection Fluorescent Probes |
spellingShingle |
Science::Medicine Acute Allograft Rejection Fluorescent Probes Cheng, Penghui Wang, Rending He, Shasha Yan, Pengpeng Huang, Hongfeng Chen, Jianghua Shen, Jia Pu, Kanyi Artificial urinary biomarkers for early diagnosis of acute renal allograft rejection |
description |
Acute renal allograft rejection (ARAR) after kidney transplantation associated with reduced graft survival and eventual graft failure is poorly diagnosed in hospitals. Here, we report the development of Artificial bioMarker Probes (AMPros) for sensitive urinalysis of ARAR in murine models. AMPros spontaneously go to the kidneys after systemic administration, specifically react with the prodromal immune biomarkers to activate their near-infrared fluorescence signals to report cell-mediated rejection, and efficiently undergo renal excretion into urine. Thus, AMPros enable convenient optical urinalysis that detects ARAR prior to histological manifestation of rejection, which is also earlier than current diagnostic methods measuring proinflammatory cytokines and peripheral blood lymphocyte mRNAs. Due to the high kidney specificity, AMPros-based urinalysis discriminates allograft rejection against other non-alloimmune specific diseases, which is unattainable by measurement of serological biomarkers. Such a noninvasive and sensitive urine test holds great promise in continuous monitoring of renal allograft conditions at low resource settings for timely clinical interventions. |
author2 |
Lee Kong Chian School of Medicine (LKCMedicine) |
author_facet |
Lee Kong Chian School of Medicine (LKCMedicine) Cheng, Penghui Wang, Rending He, Shasha Yan, Pengpeng Huang, Hongfeng Chen, Jianghua Shen, Jia Pu, Kanyi |
format |
Article |
author |
Cheng, Penghui Wang, Rending He, Shasha Yan, Pengpeng Huang, Hongfeng Chen, Jianghua Shen, Jia Pu, Kanyi |
author_sort |
Cheng, Penghui |
title |
Artificial urinary biomarkers for early diagnosis of acute renal allograft rejection |
title_short |
Artificial urinary biomarkers for early diagnosis of acute renal allograft rejection |
title_full |
Artificial urinary biomarkers for early diagnosis of acute renal allograft rejection |
title_fullStr |
Artificial urinary biomarkers for early diagnosis of acute renal allograft rejection |
title_full_unstemmed |
Artificial urinary biomarkers for early diagnosis of acute renal allograft rejection |
title_sort |
artificial urinary biomarkers for early diagnosis of acute renal allograft rejection |
publishDate |
2023 |
url |
https://hdl.handle.net/10356/170998 |
_version_ |
1781793808671834112 |