Finite element analysis using ANSYS for piping structure under self load stress

This project aims to find the stress level and the displacement of the pipeline. The use of Finite Element Analysis is computer-aided software that uses to calculate the engineering application. It is a fundamentally an approximation of an underlying mathematical model to the real physical applicati...

Full description

Saved in:
Bibliographic Details
Main Author: Lim, Woon Lai.
Other Authors: Zhong Zhaowei
Format: Final Year Project
Language:English
Published: 2009
Subjects:
Online Access:http://hdl.handle.net/10356/17196
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-17196
record_format dspace
spelling sg-ntu-dr.10356-171962023-03-04T18:35:58Z Finite element analysis using ANSYS for piping structure under self load stress Lim, Woon Lai. Zhong Zhaowei School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering::Mechanics and dynamics This project aims to find the stress level and the displacement of the pipeline. The use of Finite Element Analysis is computer-aided software that uses to calculate the engineering application. It is a fundamentally an approximation of an underlying mathematical model to the real physical application. Its boundary conditions approximate the application is supported with the material properties assumed are approximate also. Many details are idealized, simplified or ignored. Today, a lot of engineering, civil engineering and other disciplines problems are using finite element analysis to analyze problems. It calculates the stress, strain, vibration, deflection, buckling and others separately, and then it analyzes all the data and gives an acceptable approximate value. We are using the finite element analysis software ANSYS to find the stresses and displacement of the pipe structural build. In the pipe structural, there is other equipment other than the pipe itself. In this pipe structural, we are using APL 5L X60 steel pipes and equipment like filter, ultrasonic gas flow meters, flanges, flow control valve, check valve and different sizes of valves. We will analyze only one section of the pipe structural for the displacement and stresses. With the result of the analysis, we can then see whether we need to add or reduce the supports to the pipe structural. Bachelor of Engineering (Mechanical Engineering) 2009-06-01T06:33:03Z 2009-06-01T06:33:03Z 2009 2009 Final Year Project (FYP) http://hdl.handle.net/10356/17196 en Nanyang Technological University 70 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering::Mechanics and dynamics
spellingShingle DRNTU::Engineering::Mechanical engineering::Mechanics and dynamics
Lim, Woon Lai.
Finite element analysis using ANSYS for piping structure under self load stress
description This project aims to find the stress level and the displacement of the pipeline. The use of Finite Element Analysis is computer-aided software that uses to calculate the engineering application. It is a fundamentally an approximation of an underlying mathematical model to the real physical application. Its boundary conditions approximate the application is supported with the material properties assumed are approximate also. Many details are idealized, simplified or ignored. Today, a lot of engineering, civil engineering and other disciplines problems are using finite element analysis to analyze problems. It calculates the stress, strain, vibration, deflection, buckling and others separately, and then it analyzes all the data and gives an acceptable approximate value. We are using the finite element analysis software ANSYS to find the stresses and displacement of the pipe structural build. In the pipe structural, there is other equipment other than the pipe itself. In this pipe structural, we are using APL 5L X60 steel pipes and equipment like filter, ultrasonic gas flow meters, flanges, flow control valve, check valve and different sizes of valves. We will analyze only one section of the pipe structural for the displacement and stresses. With the result of the analysis, we can then see whether we need to add or reduce the supports to the pipe structural.
author2 Zhong Zhaowei
author_facet Zhong Zhaowei
Lim, Woon Lai.
format Final Year Project
author Lim, Woon Lai.
author_sort Lim, Woon Lai.
title Finite element analysis using ANSYS for piping structure under self load stress
title_short Finite element analysis using ANSYS for piping structure under self load stress
title_full Finite element analysis using ANSYS for piping structure under self load stress
title_fullStr Finite element analysis using ANSYS for piping structure under self load stress
title_full_unstemmed Finite element analysis using ANSYS for piping structure under self load stress
title_sort finite element analysis using ansys for piping structure under self load stress
publishDate 2009
url http://hdl.handle.net/10356/17196
_version_ 1759856848031186944