Time series to spatiotemporal HRV & hemodynamic assessment tool with blood pressure estimation

Cardiovascular diseases (CVD) are the leading cause of morbidity and mortality worldwide, influenced by genetics, environment, and lifestyle. Heart Rate Variability (HRV) serves as a critical tool for gauging autonomic regulation and cardiovascular health, offering insights into early cardiovascular...

Full description

Saved in:
Bibliographic Details
Main Author: Chin, Ryan Ray Kang
Other Authors: Ng Yin Kwee
Format: Final Year Project
Language:English
Published: Nanyang Technological University 2024
Subjects:
Online Access:https://hdl.handle.net/10356/176145
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-176145
record_format dspace
spelling sg-ntu-dr.10356-1761452024-05-29T01:49:39Z Time series to spatiotemporal HRV & hemodynamic assessment tool with blood pressure estimation Chin, Ryan Ray Kang Ng Yin Kwee School of Mechanical and Aerospace Engineering MYKNG@ntu.edu.sg Computer and Information Science Engineering Medicine, Health and Life Sciences Cardiovascular diseases (CVD) are the leading cause of morbidity and mortality worldwide, influenced by genetics, environment, and lifestyle. Heart Rate Variability (HRV) serves as a critical tool for gauging autonomic regulation and cardiovascular health, offering insights into early cardiovascular stress and risk of CVD through non-invasive means. Unlike ECG which requires electrode placement, monitoring hemodynamics via Photoplethysmography (PPG) is also non-invasive but simpler, further aiding in early CVD detection. Key factors like monitoring blood pressure and blood sugar levels are essential in preventing CVD progression, which currently require inconvenient monitoring methods namely blood pressure cuffs and finger prick. This has spurred interest in developing more accessible, non-invasive technologies. This project will explore the above mentioned, to begin, Electrocardiogram (ECG) and Photoplethysmogram (PPG) signals are collect through a 3min data collection process from volunteers wearing a prototype wearable. The signals will go through a series of pre-processing before extracting the relevant data of the 4 main highlights of this project. (1) HRV analysis using HRV and CHA bandwidths which converts the time series of peak-to-peak interval (PPI) of PPG signals into a spatiotemporal form. Though ECG is conventionally used HRV analysis, PPG offers a non-invasive method of monitoring. Both bandwidth methods are analyzed with different groups namely age, gender, blood pressure, BMI, and the presence of medical conditions. The bandwidths also serve as a method for long term health and drug efficacy monitoring. (2) A blood pressure estimation was attempted using 11 features extracted from the ECG and PPG signals acquired from the data collection. Various Machine Learning (ML) and Neural Network (NN) models, including Physics-Informed Neural Networks (PINN), were attempted. The PINN model came up on top with an MAE of 4.80 and 3.66 mmHg for systolic and diastolic blood pressures respectively. The predictions also met the AAMI and BHS standards for BP measurement accuracy. (3) Plethysmorphometry (PMM), which is a 3D model of 2 or more PPG signals overlaid over one another, representing of the entire time series of PPG signals. The changes in hemodynamics or morphology of the PMM was analyzed on the Oral Glucose Tolerance Test (OGTT) volunteers. Findings of this project showed a less steep gradient following the systolic peak in the PMM and higher blood glucose levels (BGLs). (4) Finally, all components will be integrated and presented through a Graphic User Interface (GUI) application to simplify the overall analysis process. Bachelor's degree 2024-05-29T01:49:39Z 2024-05-29T01:49:39Z 2024 Final Year Project (FYP) Chin, R. R. K. (2024). Time series to spatiotemporal HRV & hemodynamic assessment tool with blood pressure estimation. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/176145 https://hdl.handle.net/10356/176145 en application/pdf Nanyang Technological University
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Computer and Information Science
Engineering
Medicine, Health and Life Sciences
spellingShingle Computer and Information Science
Engineering
Medicine, Health and Life Sciences
Chin, Ryan Ray Kang
Time series to spatiotemporal HRV & hemodynamic assessment tool with blood pressure estimation
description Cardiovascular diseases (CVD) are the leading cause of morbidity and mortality worldwide, influenced by genetics, environment, and lifestyle. Heart Rate Variability (HRV) serves as a critical tool for gauging autonomic regulation and cardiovascular health, offering insights into early cardiovascular stress and risk of CVD through non-invasive means. Unlike ECG which requires electrode placement, monitoring hemodynamics via Photoplethysmography (PPG) is also non-invasive but simpler, further aiding in early CVD detection. Key factors like monitoring blood pressure and blood sugar levels are essential in preventing CVD progression, which currently require inconvenient monitoring methods namely blood pressure cuffs and finger prick. This has spurred interest in developing more accessible, non-invasive technologies. This project will explore the above mentioned, to begin, Electrocardiogram (ECG) and Photoplethysmogram (PPG) signals are collect through a 3min data collection process from volunteers wearing a prototype wearable. The signals will go through a series of pre-processing before extracting the relevant data of the 4 main highlights of this project. (1) HRV analysis using HRV and CHA bandwidths which converts the time series of peak-to-peak interval (PPI) of PPG signals into a spatiotemporal form. Though ECG is conventionally used HRV analysis, PPG offers a non-invasive method of monitoring. Both bandwidth methods are analyzed with different groups namely age, gender, blood pressure, BMI, and the presence of medical conditions. The bandwidths also serve as a method for long term health and drug efficacy monitoring. (2) A blood pressure estimation was attempted using 11 features extracted from the ECG and PPG signals acquired from the data collection. Various Machine Learning (ML) and Neural Network (NN) models, including Physics-Informed Neural Networks (PINN), were attempted. The PINN model came up on top with an MAE of 4.80 and 3.66 mmHg for systolic and diastolic blood pressures respectively. The predictions also met the AAMI and BHS standards for BP measurement accuracy. (3) Plethysmorphometry (PMM), which is a 3D model of 2 or more PPG signals overlaid over one another, representing of the entire time series of PPG signals. The changes in hemodynamics or morphology of the PMM was analyzed on the Oral Glucose Tolerance Test (OGTT) volunteers. Findings of this project showed a less steep gradient following the systolic peak in the PMM and higher blood glucose levels (BGLs). (4) Finally, all components will be integrated and presented through a Graphic User Interface (GUI) application to simplify the overall analysis process.
author2 Ng Yin Kwee
author_facet Ng Yin Kwee
Chin, Ryan Ray Kang
format Final Year Project
author Chin, Ryan Ray Kang
author_sort Chin, Ryan Ray Kang
title Time series to spatiotemporal HRV & hemodynamic assessment tool with blood pressure estimation
title_short Time series to spatiotemporal HRV & hemodynamic assessment tool with blood pressure estimation
title_full Time series to spatiotemporal HRV & hemodynamic assessment tool with blood pressure estimation
title_fullStr Time series to spatiotemporal HRV & hemodynamic assessment tool with blood pressure estimation
title_full_unstemmed Time series to spatiotemporal HRV & hemodynamic assessment tool with blood pressure estimation
title_sort time series to spatiotemporal hrv & hemodynamic assessment tool with blood pressure estimation
publisher Nanyang Technological University
publishDate 2024
url https://hdl.handle.net/10356/176145
_version_ 1814047092628258816