Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy
Daily quality assurance is an integral part of a radiotherapy workflow to ensure the dose is delivered safely and accurately to the patient. It is performed before the first treatment of the day and needs to be time and cost efficient for a multiple gantries proton center. In this study, we introduc...
Saved in:
Main Authors: | , , , , , , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2024
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/179684 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-179684 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1796842024-08-19T15:35:08Z Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy Tan, Hong Qi Koh, Calvin Wei Yang Lew, Kah Seng Yeap, Ping Lin Chua, Clifford Ghee Ann Lee, James Kuan Huei Wong, Yun Ming Wibawa, Andrew Master, Zubin Lee, James Cheow Lei Park, Sung Yong School of Physical and Mathematical Sciences Physics Pencil beam scanning Proton therapy Daily quality assurance is an integral part of a radiotherapy workflow to ensure the dose is delivered safely and accurately to the patient. It is performed before the first treatment of the day and needs to be time and cost efficient for a multiple gantries proton center. In this study, we introduced an efficient method to perform QA for output constancy, range verification, spot positioning accuracy and imaging and proton beam isocenter coincidence with DailyQA3. Published version Hong Qi Tan is supported by the Duke-NUS Oncology Academic Program Goh Foundation Proton Research Program (08/FY2021/EX(SL)/92-A146), Clinical & Systems Innovation Support—Innovation Seed Grant (08/FY2022/P2/02-A68). 2024-08-16T05:15:34Z 2024-08-16T05:15:34Z 2024 Journal Article Tan, H. Q., Koh, C. W. Y., Lew, K. S., Yeap, P. L., Chua, C. G. A., Lee, J. K. H., Wong, Y. M., Wibawa, A., Master, Z., Lee, J. C. L. & Park, S. Y. (2024). Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy. Journal of Applied Clinical Medical Physics, 25(7), e14348-. https://dx.doi.org/10.1002/acm2.14348 1526-9914 https://hdl.handle.net/10356/179684 10.1002/acm2.14348 38561975 2-s2.0-85189763312 7 25 e14348 en Journal of Applied Clinical Medical Physics © 2024 The Authors. Journal of Applied Clinical Medical Physics is published by Wiley Periodicals, Inc. on behalf of The American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
Physics Pencil beam scanning Proton therapy |
spellingShingle |
Physics Pencil beam scanning Proton therapy Tan, Hong Qi Koh, Calvin Wei Yang Lew, Kah Seng Yeap, Ping Lin Chua, Clifford Ghee Ann Lee, James Kuan Huei Wong, Yun Ming Wibawa, Andrew Master, Zubin Lee, James Cheow Lei Park, Sung Yong Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy |
description |
Daily quality assurance is an integral part of a radiotherapy workflow to ensure the dose is delivered safely and accurately to the patient. It is performed before the first treatment of the day and needs to be time and cost efficient for a multiple gantries proton center. In this study, we introduced an efficient method to perform QA for output constancy, range verification, spot positioning accuracy and imaging and proton beam isocenter coincidence with DailyQA3. |
author2 |
School of Physical and Mathematical Sciences |
author_facet |
School of Physical and Mathematical Sciences Tan, Hong Qi Koh, Calvin Wei Yang Lew, Kah Seng Yeap, Ping Lin Chua, Clifford Ghee Ann Lee, James Kuan Huei Wong, Yun Ming Wibawa, Andrew Master, Zubin Lee, James Cheow Lei Park, Sung Yong |
format |
Article |
author |
Tan, Hong Qi Koh, Calvin Wei Yang Lew, Kah Seng Yeap, Ping Lin Chua, Clifford Ghee Ann Lee, James Kuan Huei Wong, Yun Ming Wibawa, Andrew Master, Zubin Lee, James Cheow Lei Park, Sung Yong |
author_sort |
Tan, Hong Qi |
title |
Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy |
title_short |
Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy |
title_full |
Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy |
title_fullStr |
Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy |
title_full_unstemmed |
Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy |
title_sort |
repurposing dailyqa3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy |
publishDate |
2024 |
url |
https://hdl.handle.net/10356/179684 |
_version_ |
1814047293753524224 |