Daily quality assurance is an integral part of a radiotherapy workflow to ensure the dose is delivered safely and accurately to the patient. It is performed before the first treatment of the day and needs to be time and cost efficient for a multiple gantries proton center. In this study, we introduc...

Full description

Saved in:
Bibliographic Details
Main Authors: Tan, Hong Qi, Koh, Calvin Wei Yang, Lew, Kah Seng, Yeap, Ping Lin, Chua, Clifford Ghee Ann, Lee, James Kuan Huei, Wong, Yun Ming, Wibawa, Andrew, Master, Zubin, Lee, James Cheow Lei, Park, Sung Yong
Other Authors: School of Physical and Mathematical Sciences
Format: Article
Language:English
Published: 2024
Subjects:
Online Access:https://hdl.handle.net/10356/179684
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-179684
record_format dspace
spelling sg-ntu-dr.10356-1796842024-08-19T15:35:08Z Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy Tan, Hong Qi Koh, Calvin Wei Yang Lew, Kah Seng Yeap, Ping Lin Chua, Clifford Ghee Ann Lee, James Kuan Huei Wong, Yun Ming Wibawa, Andrew Master, Zubin Lee, James Cheow Lei Park, Sung Yong School of Physical and Mathematical Sciences Physics Pencil beam scanning Proton therapy Daily quality assurance is an integral part of a radiotherapy workflow to ensure the dose is delivered safely and accurately to the patient. It is performed before the first treatment of the day and needs to be time and cost efficient for a multiple gantries proton center. In this study, we introduced an efficient method to perform QA for output constancy, range verification, spot positioning accuracy and imaging and proton beam isocenter coincidence with DailyQA3. Published version Hong Qi Tan is supported by the Duke-NUS Oncology Academic Program Goh Foundation Proton Research Program (08/FY2021/EX(SL)/92-A146), Clinical & Systems Innovation Support—Innovation Seed Grant (08/FY2022/P2/02-A68). 2024-08-16T05:15:34Z 2024-08-16T05:15:34Z 2024 Journal Article Tan, H. Q., Koh, C. W. Y., Lew, K. S., Yeap, P. L., Chua, C. G. A., Lee, J. K. H., Wong, Y. M., Wibawa, A., Master, Z., Lee, J. C. L. & Park, S. Y. (2024). Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy. Journal of Applied Clinical Medical Physics, 25(7), e14348-. https://dx.doi.org/10.1002/acm2.14348 1526-9914 https://hdl.handle.net/10356/179684 10.1002/acm2.14348 38561975 2-s2.0-85189763312 7 25 e14348 en Journal of Applied Clinical Medical Physics © 2024 The Authors. Journal of Applied Clinical Medical Physics is published by Wiley Periodicals, Inc. on behalf of The American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Physics
Pencil beam scanning
Proton therapy
spellingShingle Physics
Pencil beam scanning
Proton therapy
Tan, Hong Qi
Koh, Calvin Wei Yang
Lew, Kah Seng
Yeap, Ping Lin
Chua, Clifford Ghee Ann
Lee, James Kuan Huei
Wong, Yun Ming
Wibawa, Andrew
Master, Zubin
Lee, James Cheow Lei
Park, Sung Yong
Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy
description Daily quality assurance is an integral part of a radiotherapy workflow to ensure the dose is delivered safely and accurately to the patient. It is performed before the first treatment of the day and needs to be time and cost efficient for a multiple gantries proton center. In this study, we introduced an efficient method to perform QA for output constancy, range verification, spot positioning accuracy and imaging and proton beam isocenter coincidence with DailyQA3.
author2 School of Physical and Mathematical Sciences
author_facet School of Physical and Mathematical Sciences
Tan, Hong Qi
Koh, Calvin Wei Yang
Lew, Kah Seng
Yeap, Ping Lin
Chua, Clifford Ghee Ann
Lee, James Kuan Huei
Wong, Yun Ming
Wibawa, Andrew
Master, Zubin
Lee, James Cheow Lei
Park, Sung Yong
format Article
author Tan, Hong Qi
Koh, Calvin Wei Yang
Lew, Kah Seng
Yeap, Ping Lin
Chua, Clifford Ghee Ann
Lee, James Kuan Huei
Wong, Yun Ming
Wibawa, Andrew
Master, Zubin
Lee, James Cheow Lei
Park, Sung Yong
author_sort Tan, Hong Qi
title Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy
title_short Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy
title_full Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy
title_fullStr Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy
title_full_unstemmed Repurposing DailyQA3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy
title_sort repurposing dailyqa3 for an efficient and spot position sensitive daily quality assurance tool for proton therapy
publishDate 2024
url https://hdl.handle.net/10356/179684
_version_ 1814047293753524224