Effect of multi-unit and multi-type DG installation using integrated optimization technique in distribution power system planning

With the rise in load demand, improving the voltage profile and reducing line loss is vital to ensure reliable power delivery to the customer. However, increasing power plant generation capacity is limited by environmental and economic factors, requiring a careful assessment of locally optimal optio...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdullah, Azlina, Musirin, Ismail, Othman, Muhammad Murtadha, Rahim, Siti Rafidah Abdul, Mansor, Mohd Helmi, Shaaya, Sharifah Azwa, Aminuddin, Norziana, Goel, Lalit Kumar
Other Authors: School of Electrical and Electronic Engineering
Format: Article
Language:English
Published: 2024
Subjects:
Online Access:https://hdl.handle.net/10356/181348
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-181348
record_format dspace
spelling sg-ntu-dr.10356-1813482024-11-26T04:45:59Z Effect of multi-unit and multi-type DG installation using integrated optimization technique in distribution power system planning Abdullah, Azlina Musirin, Ismail Othman, Muhammad Murtadha Rahim, Siti Rafidah Abdul Mansor, Mohd Helmi Shaaya, Sharifah Azwa Aminuddin, Norziana Goel, Lalit Kumar School of Electrical and Electronic Engineering Engineering Distributed generation Evolution programming With the rise in load demand, improving the voltage profile and reducing line loss is vital to ensure reliable power delivery to the customer. However, increasing power plant generation capacity is limited by environmental and economic factors, requiring a careful assessment of locally optimal options. Distributed Generation (DG) installation into the electricity grid is one of the reliable remedial actions to ensure a smooth power delivery. Installation of DG requires an optimization process to identify the appropriate placement and sizing. Inaccurate sizing and placement of the DG installation may result to over-compensation or under-compensation phenomena. This paper proposes a novel approach termed the Integrated Immune Moth Flame Evolutionary Programming technique (IIMFEP) for optimizing the installation of DG sources in distribution systems. It handles various scenarios, including multi-DG single-type and multi-DG multi-type installations, with the main objective of minimizing power loss in the system. This technique employs a hybrid approach that combines elements of immune algorithms, moth flame optimization, and evolutionary programming to achieve more accurate and efficient results. Two cases were considered in this study termed Case 1 and Case 2. Results in Case 1 discovered that the optimal sizing and placement of four Type III DGs exhibit the lowest power loss worth 2.74 kW (98.78 % reduction) for the 69-Bus RDS, while for the 118-Bus RDS the power loss is 319.89 kW (75.36 % reduction). In Case Study 2, the combination of DG Types I and III provided the highest power loss reduction. With one DG Type I and two DG Type III units installed, power loss was reduced by 97.15 % to 6.41 kW for the 69-Bus RDS and by 62.01 % to 493.21 kW for the 118-Bus RDS. The proposed IIMFEP managed to alleviate the setback experienced in the traditional EP, AIS and MFO which found to be stuck at local optimum. The IIMFEP method is compared to Moth Flame Optimization, Artificial Immune System and Evolutionary Programming and validated using the IEEE 69-Bus and 118-Bus Radial Distribution Systems, resulting in outstanding performance. Published version The authors would like to acknowledge the Ministry of Higher Education, Malaysia (MOHE) and Universiti Teknologi Mara (UiTM) Shah Alam, Selangor, Malaysia for the financial support. This project is by MOHE under Fundamental Research Grant Scheme (FRGS) with project code: FRGS/1/2019/TK04/UITM/01/1 and 600-IRMI/FRGS 5/3 (381/ 2019). 2024-11-26T04:45:59Z 2024-11-26T04:45:59Z 2024 Journal Article Abdullah, A., Musirin, I., Othman, M. M., Rahim, S. R. A., Mansor, M. H., Shaaya, S. A., Aminuddin, N. & Goel, L. K. (2024). Effect of multi-unit and multi-type DG installation using integrated optimization technique in distribution power system planning. Alexandria Engineering Journal, 107, 895-914. https://dx.doi.org/10.1016/j.aej.2024.09.006 1110-0168 https://hdl.handle.net/10356/181348 10.1016/j.aej.2024.09.006 2-s2.0-85204057752 107 895 914 en Alexandria Engineering Journal © 2024 The Author(s). Published by Elsevier BV on behalf of Faculty of Engineering, Alexandria University This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering
Distributed generation
Evolution programming
spellingShingle Engineering
Distributed generation
Evolution programming
Abdullah, Azlina
Musirin, Ismail
Othman, Muhammad Murtadha
Rahim, Siti Rafidah Abdul
Mansor, Mohd Helmi
Shaaya, Sharifah Azwa
Aminuddin, Norziana
Goel, Lalit Kumar
Effect of multi-unit and multi-type DG installation using integrated optimization technique in distribution power system planning
description With the rise in load demand, improving the voltage profile and reducing line loss is vital to ensure reliable power delivery to the customer. However, increasing power plant generation capacity is limited by environmental and economic factors, requiring a careful assessment of locally optimal options. Distributed Generation (DG) installation into the electricity grid is one of the reliable remedial actions to ensure a smooth power delivery. Installation of DG requires an optimization process to identify the appropriate placement and sizing. Inaccurate sizing and placement of the DG installation may result to over-compensation or under-compensation phenomena. This paper proposes a novel approach termed the Integrated Immune Moth Flame Evolutionary Programming technique (IIMFEP) for optimizing the installation of DG sources in distribution systems. It handles various scenarios, including multi-DG single-type and multi-DG multi-type installations, with the main objective of minimizing power loss in the system. This technique employs a hybrid approach that combines elements of immune algorithms, moth flame optimization, and evolutionary programming to achieve more accurate and efficient results. Two cases were considered in this study termed Case 1 and Case 2. Results in Case 1 discovered that the optimal sizing and placement of four Type III DGs exhibit the lowest power loss worth 2.74 kW (98.78 % reduction) for the 69-Bus RDS, while for the 118-Bus RDS the power loss is 319.89 kW (75.36 % reduction). In Case Study 2, the combination of DG Types I and III provided the highest power loss reduction. With one DG Type I and two DG Type III units installed, power loss was reduced by 97.15 % to 6.41 kW for the 69-Bus RDS and by 62.01 % to 493.21 kW for the 118-Bus RDS. The proposed IIMFEP managed to alleviate the setback experienced in the traditional EP, AIS and MFO which found to be stuck at local optimum. The IIMFEP method is compared to Moth Flame Optimization, Artificial Immune System and Evolutionary Programming and validated using the IEEE 69-Bus and 118-Bus Radial Distribution Systems, resulting in outstanding performance.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Abdullah, Azlina
Musirin, Ismail
Othman, Muhammad Murtadha
Rahim, Siti Rafidah Abdul
Mansor, Mohd Helmi
Shaaya, Sharifah Azwa
Aminuddin, Norziana
Goel, Lalit Kumar
format Article
author Abdullah, Azlina
Musirin, Ismail
Othman, Muhammad Murtadha
Rahim, Siti Rafidah Abdul
Mansor, Mohd Helmi
Shaaya, Sharifah Azwa
Aminuddin, Norziana
Goel, Lalit Kumar
author_sort Abdullah, Azlina
title Effect of multi-unit and multi-type DG installation using integrated optimization technique in distribution power system planning
title_short Effect of multi-unit and multi-type DG installation using integrated optimization technique in distribution power system planning
title_full Effect of multi-unit and multi-type DG installation using integrated optimization technique in distribution power system planning
title_fullStr Effect of multi-unit and multi-type DG installation using integrated optimization technique in distribution power system planning
title_full_unstemmed Effect of multi-unit and multi-type DG installation using integrated optimization technique in distribution power system planning
title_sort effect of multi-unit and multi-type dg installation using integrated optimization technique in distribution power system planning
publishDate 2024
url https://hdl.handle.net/10356/181348
_version_ 1816859036683862016