Development of an enclosed-impeller ventricular assist device using self-bearing motor

Congestive heart disease is currently a major killer. Hence, there is an increasing need for implantable artificial hearts as an alternative to donor hearts which cannot meet the needs. The development of magnetically suspended Ventricular Assist Devices (VADs), alias blood pumps, has been a promisi...

Full description

Saved in:
Bibliographic Details
Main Author: Zhang, Dongsheng
Other Authors: Lim Tau Meng
Format: Theses and Dissertations
Language:English
Published: 2009
Subjects:
Online Access:https://hdl.handle.net/10356/18761
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-18761
record_format dspace
spelling sg-ntu-dr.10356-187612023-03-11T17:46:26Z Development of an enclosed-impeller ventricular assist device using self-bearing motor Zhang, Dongsheng Lim Tau Meng School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering::Assistive technology Congestive heart disease is currently a major killer. Hence, there is an increasing need for implantable artificial hearts as an alternative to donor hearts which cannot meet the needs. The development of magnetically suspended Ventricular Assist Devices (VADs), alias blood pumps, has been a promising option for this purpose in recent years. In order to overcome the limitations of the current axial flow blood pump available, such as low motoring and pump efficiencies as well as large size, an axial-flow blood pump featuring an enclosed-impeller and self-bearing motors is proposed in this thesis. Computational fluid dynamics (CFD) analysis is carried out to analyze the pump characteristics of the proposed blood pump. The results show that the proposed blood pump could provide 50 mmHg pressure head with 26% pump efficiency at the operating point of 9,000 rpm rotating speed at 5 L/min flow rate. The maximum blood shear stress and maximum blood exposure time is 200 Pa and 146 ms respectively, which indicates lower blood trauma tendency in the proposed blood pump. A prototyped Lorentz force type self-bearing motor test rig is designed with the aid of finite element analysis (FEA) to validate the control scheme for the proposed self-bearing motor. The self-bearing motor is successful levitated by a Proportional-Integral-Derivative (PID) control scheme with a maximum displacement deviation of 0.3 mm. The maximum deviation is further reduced to 0.21 mm by the proposed PID-Robust Model Reference Adaptive Control (RMRAC). The stability control of the proposed PID-RMRAC under output disturbance is also verified through the experiments. These experimental results indicate that the proposed blood pump could be a better alterative for the future development of blood pumps. DOCTOR OF PHILOSOPHY (MAE) 2009-07-17T07:10:27Z 2009-07-17T07:10:27Z 2008 2008 Thesis Zhang, D. S. (2008). Development of an enclosed-impeller ventricular assist device using self-bearing motor. Doctoral thesis, Nanyang Technological University, Singapore. https://hdl.handle.net/10356/18761 10.32657/10356/18761 en 179 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering::Assistive technology
spellingShingle DRNTU::Engineering::Mechanical engineering::Assistive technology
Zhang, Dongsheng
Development of an enclosed-impeller ventricular assist device using self-bearing motor
description Congestive heart disease is currently a major killer. Hence, there is an increasing need for implantable artificial hearts as an alternative to donor hearts which cannot meet the needs. The development of magnetically suspended Ventricular Assist Devices (VADs), alias blood pumps, has been a promising option for this purpose in recent years. In order to overcome the limitations of the current axial flow blood pump available, such as low motoring and pump efficiencies as well as large size, an axial-flow blood pump featuring an enclosed-impeller and self-bearing motors is proposed in this thesis. Computational fluid dynamics (CFD) analysis is carried out to analyze the pump characteristics of the proposed blood pump. The results show that the proposed blood pump could provide 50 mmHg pressure head with 26% pump efficiency at the operating point of 9,000 rpm rotating speed at 5 L/min flow rate. The maximum blood shear stress and maximum blood exposure time is 200 Pa and 146 ms respectively, which indicates lower blood trauma tendency in the proposed blood pump. A prototyped Lorentz force type self-bearing motor test rig is designed with the aid of finite element analysis (FEA) to validate the control scheme for the proposed self-bearing motor. The self-bearing motor is successful levitated by a Proportional-Integral-Derivative (PID) control scheme with a maximum displacement deviation of 0.3 mm. The maximum deviation is further reduced to 0.21 mm by the proposed PID-Robust Model Reference Adaptive Control (RMRAC). The stability control of the proposed PID-RMRAC under output disturbance is also verified through the experiments. These experimental results indicate that the proposed blood pump could be a better alterative for the future development of blood pumps.
author2 Lim Tau Meng
author_facet Lim Tau Meng
Zhang, Dongsheng
format Theses and Dissertations
author Zhang, Dongsheng
author_sort Zhang, Dongsheng
title Development of an enclosed-impeller ventricular assist device using self-bearing motor
title_short Development of an enclosed-impeller ventricular assist device using self-bearing motor
title_full Development of an enclosed-impeller ventricular assist device using self-bearing motor
title_fullStr Development of an enclosed-impeller ventricular assist device using self-bearing motor
title_full_unstemmed Development of an enclosed-impeller ventricular assist device using self-bearing motor
title_sort development of an enclosed-impeller ventricular assist device using self-bearing motor
publishDate 2009
url https://hdl.handle.net/10356/18761
_version_ 1761781794174140416