New Zealand design code for slender reinforced concrete columns
The objective of this report is to study and evaluate New Zealand Design code (NZS3101:2006) for Slender Reinforced Concrete. P-Delta method, BS8110:1997 Design method and transformation concept are also considered in this report. This report considers only pin-ended rectangular columns under uniaxi...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
2009
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/20607 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
Summary: | The objective of this report is to study and evaluate New Zealand Design code (NZS3101:2006) for Slender Reinforced Concrete. P-Delta method, BS8110:1997 Design method and transformation concept are also considered in this report. This report considers only pin-ended rectangular columns under uniaxial bending and short-term loading. The calculated failure loads are compared with the experimental values obtained from 34 columns by Cranston and 26 columns by Chuang and Kong (1997) and 6 columns from Chuang, Kong, SK and Kong, F.K, Column Series (2000). The range of compressive strength of concrete (fcu) and steel ratio (As/bh) are 24.7N/mm2 – 96.2 N/mm2 and 1.0% - 3.24% respectively. |
---|