Continuous cardiac output monitoring system
A technique of continuous cardiac output (CO) measurement without injection of foreign fluids is discussed in this report. The cardiac output is obtained by multiplying the instantaneous cross-sectional area of the blood vessel with the blood flow velocity. The hardware and probes used for real time...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Research Report |
Published: |
2008
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/3019 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
id |
sg-ntu-dr.10356-3019 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-30192023-03-04T03:23:41Z Continuous cardiac output monitoring system Tjin, Swee Chuan. School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Medical electronics A technique of continuous cardiac output (CO) measurement without injection of foreign fluids is discussed in this report. The cardiac output is obtained by multiplying the instantaneous cross-sectional area of the blood vessel with the blood flow velocity. The hardware and probes used for real time CO measurements are discussed. This technique of real time cardiac monitoring has been proven experimentally to be feasible. Accurate and linear results have been obtained. ARC 4/94 2008-09-17T09:18:56Z 2008-09-17T09:18:56Z 1999 1999 Research Report http://hdl.handle.net/10356/3019 Nanyang Technological University application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
topic |
DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Medical electronics |
spellingShingle |
DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Medical electronics Tjin, Swee Chuan. Continuous cardiac output monitoring system |
description |
A technique of continuous cardiac output (CO) measurement without injection of foreign fluids is discussed in this report. The cardiac output is obtained by multiplying the instantaneous cross-sectional area of the blood vessel with the blood flow velocity. The hardware and probes used for real time CO measurements are discussed. This technique of real time cardiac monitoring has been proven experimentally to be feasible. Accurate and linear results have been obtained. |
author2 |
School of Electrical and Electronic Engineering |
author_facet |
School of Electrical and Electronic Engineering Tjin, Swee Chuan. |
format |
Research Report |
author |
Tjin, Swee Chuan. |
author_sort |
Tjin, Swee Chuan. |
title |
Continuous cardiac output monitoring system |
title_short |
Continuous cardiac output monitoring system |
title_full |
Continuous cardiac output monitoring system |
title_fullStr |
Continuous cardiac output monitoring system |
title_full_unstemmed |
Continuous cardiac output monitoring system |
title_sort |
continuous cardiac output monitoring system |
publishDate |
2008 |
url |
http://hdl.handle.net/10356/3019 |
_version_ |
1759856899199598592 |