Measurements of hemodynamics in coronary artery bypass using particle image velocimetry : an in-vitro study
298 p.
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Theses and Dissertations |
Published: |
2010
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/35980 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
id |
sg-ntu-dr.10356-35980 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-359802023-03-11T16:56:24Z Measurements of hemodynamics in coronary artery bypass using particle image velocimetry : an in-vitro study Ji, Wenfa Chua Leok Poh School of Mechanical and Aerospace Engineering DRNTU::Engineering::Bioengineering 298 p. Coronary artery bypass grafting, the major treatment for coronary stenosis, has long-term patency problem due to intimal hyperplasia along the graft and at the graft/artery junction (proximal and distal anastomoses). It is well demonstrated that the hemodynamic factors are linked to the development of intimal hyperplasia and have been hypothesized as a cause of bypass graft failure. Although some researchers had investigated distal anastomosis, further studies upon the proximal anastomosis and even the complete bypass model, including both proximal and distal anastomoses, are still lacking in the literature and it is important and necessary for a better understanding of CABG. Therefore in this project, flow characteristics and hemodynamic parameters (HPs) distributions of proximal anastomosis and the whole bypass model were studied in order to enhance the understanding of the stenosis pathophysiological process and provide useful information for sleeve design and medical doctors. Furthermore, geometrical improvement to the distal anastomosis was proposed to reduce the nonuniformity of hemodynamics and the hemodynamic performance was evaluated and compared with a baseline distal anastomosis model. DOCTOR OF PHILOSOPHY (MAE) 2010-04-23T02:21:39Z 2010-04-23T02:21:39Z 2007 2007 Thesis Ji, W. F. (2007). Measurements of hemodynamics in coronary artery bypass using particle image velocimetry : an in-vitro study. Doctoral thesis, Nanyang Technological University, Singapore. https://hdl.handle.net/10356/35980 10.32657/10356/35980 application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
topic |
DRNTU::Engineering::Bioengineering |
spellingShingle |
DRNTU::Engineering::Bioengineering Ji, Wenfa Measurements of hemodynamics in coronary artery bypass using particle image velocimetry : an in-vitro study |
description |
298 p. |
author2 |
Chua Leok Poh |
author_facet |
Chua Leok Poh Ji, Wenfa |
format |
Theses and Dissertations |
author |
Ji, Wenfa |
author_sort |
Ji, Wenfa |
title |
Measurements of hemodynamics in coronary artery bypass using particle image velocimetry : an in-vitro study |
title_short |
Measurements of hemodynamics in coronary artery bypass using particle image velocimetry : an in-vitro study |
title_full |
Measurements of hemodynamics in coronary artery bypass using particle image velocimetry : an in-vitro study |
title_fullStr |
Measurements of hemodynamics in coronary artery bypass using particle image velocimetry : an in-vitro study |
title_full_unstemmed |
Measurements of hemodynamics in coronary artery bypass using particle image velocimetry : an in-vitro study |
title_sort |
measurements of hemodynamics in coronary artery bypass using particle image velocimetry : an in-vitro study |
publishDate |
2010 |
url |
https://hdl.handle.net/10356/35980 |
_version_ |
1761781241201295360 |