Bed protection below culvert outlets

Riprap continues to be the most widely used method for protection of erodible channel boundaries. In this report, an experimental study was conducted to understand the mechanisms and characteristics of scour without protection below culvert outlets, and thereby investigating a suitably sized riprap...

Full description

Saved in:
Bibliographic Details
Main Author: Ma, Yin
Other Authors: Lim Siow Yong
Format: Final Year Project
Language:English
Published: 2010
Subjects:
Online Access:http://hdl.handle.net/10356/39600
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-39600
record_format dspace
spelling sg-ntu-dr.10356-396002023-03-03T17:16:47Z Bed protection below culvert outlets Ma, Yin Lim Siow Yong School of Civil and Environmental Engineering DRNTU::Engineering::Environmental engineering Riprap continues to be the most widely used method for protection of erodible channel boundaries. In this report, an experimental study was conducted to understand the mechanisms and characteristics of scour without protection below culvert outlets, and thereby investigating a suitably sized riprap protection for the bed material to reduce the scouring effect of the jet flow. The basis of protection is by laying a blanket of riprap stones at culvert outlets to dissipate the highly erosive kinetic energy of the discharge. Two sets of experiments were done. The first set sought to understand the basic characteristics of scour without protection. Based on the experiments conducted, it was found the scour depth and geometry depends on the tailwater depth and Froude number. The second set investigated the effects of varying size and thickness of riprap blanket on the downstream condition at incipient flow velocities below the culvert outlets. The results were compared with the first set under the same test condition. It was found the riprap protection significantly minimizes the scour condition and the optimum thickness of the riprap layer was 2D50. The empirical relations between the size of stone with flow velocity and Froude number were proposed as well. Bachelor of Engineering (Environmental Engineering) 2010-06-01T06:03:50Z 2010-06-01T06:03:50Z 2010 2010 Final Year Project (FYP) http://hdl.handle.net/10356/39600 en Nanyang Technological University 109 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Environmental engineering
spellingShingle DRNTU::Engineering::Environmental engineering
Ma, Yin
Bed protection below culvert outlets
description Riprap continues to be the most widely used method for protection of erodible channel boundaries. In this report, an experimental study was conducted to understand the mechanisms and characteristics of scour without protection below culvert outlets, and thereby investigating a suitably sized riprap protection for the bed material to reduce the scouring effect of the jet flow. The basis of protection is by laying a blanket of riprap stones at culvert outlets to dissipate the highly erosive kinetic energy of the discharge. Two sets of experiments were done. The first set sought to understand the basic characteristics of scour without protection. Based on the experiments conducted, it was found the scour depth and geometry depends on the tailwater depth and Froude number. The second set investigated the effects of varying size and thickness of riprap blanket on the downstream condition at incipient flow velocities below the culvert outlets. The results were compared with the first set under the same test condition. It was found the riprap protection significantly minimizes the scour condition and the optimum thickness of the riprap layer was 2D50. The empirical relations between the size of stone with flow velocity and Froude number were proposed as well.
author2 Lim Siow Yong
author_facet Lim Siow Yong
Ma, Yin
format Final Year Project
author Ma, Yin
author_sort Ma, Yin
title Bed protection below culvert outlets
title_short Bed protection below culvert outlets
title_full Bed protection below culvert outlets
title_fullStr Bed protection below culvert outlets
title_full_unstemmed Bed protection below culvert outlets
title_sort bed protection below culvert outlets
publishDate 2010
url http://hdl.handle.net/10356/39600
_version_ 1759855087065235456