Quantitative glucose detection by surface-enhanced Raman spectroscopy using viologens as reporter.

This research presents the study towards a glucose biosensor using surface-enhanced Raman scattering (SERS) spectroscopy with benzyl viologen boronic acid (BVB1). According to previous studies, glucose has been difficult to detect by SERS due to its poor Raman cross section and its inability to abso...

Full description

Saved in:
Bibliographic Details
Main Author: Cheng, Chun Chieh.
Other Authors: School of Chemical and Biomedical Engineering
Format: Final Year Project
Language:English
Published: 2010
Subjects:
Online Access:http://hdl.handle.net/10356/39833
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-39833
record_format dspace
spelling sg-ntu-dr.10356-398332023-03-03T15:35:33Z Quantitative glucose detection by surface-enhanced Raman spectroscopy using viologens as reporter. Cheng, Chun Chieh. School of Chemical and Biomedical Engineering A*STAR Singapore Bioimaging Consortium, Bio-Optical Imaging Group Kim Donghwan, Richie Praveen Thoniyot DRNTU::Engineering::Chemical engineering::Biotechnology This research presents the study towards a glucose biosensor using surface-enhanced Raman scattering (SERS) spectroscopy with benzyl viologen boronic acid (BVB1). According to previous studies, glucose has been difficult to detect by SERS due to its poor Raman cross section and its inability to absorb onto metallic surfaces. In this report, the study of indirect glucose detection via SERS is documented. Previous studies have shown the affinity of boronic acid towards monosaccharides. By incorporating the usage of Au substrates and a monolayer of BVB1, glucose molecules are captured by the boronic acid groups of BVB1, inducing conformation and orientation changes. Analysis of the SERS data collected suggests that glucose could be quantitatively detected in the physiological concentration range, with a linear predictive capability. The results obtained also fall within the acceptable regions of the Clarke error grid (Region A and B). The root-mean-square error of calibration (RMSEC) is approximately 41.24 mg/dl (2.29 mM) which is comparable to other studies. Data collected on the surface modification of silver/gold (bimetallic) film over nanospheres (FON) also demonstrated the theoretical mechanism of glucose sensing proposed by the group. Future works would include optimizing the sensing system by covalently binding BVB1 with the Au surface as well as using fiber optics, to produce a real time, in vivo glucose monitoring option that is minimally invasive. Bachelor of Engineering (Chemical and Biomolecular Engineering) 2010-06-07T02:51:21Z 2010-06-07T02:51:21Z 2010 2010 Final Year Project (FYP) http://hdl.handle.net/10356/39833 en Nanyang Technological University 48 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Chemical engineering::Biotechnology
spellingShingle DRNTU::Engineering::Chemical engineering::Biotechnology
Cheng, Chun Chieh.
Quantitative glucose detection by surface-enhanced Raman spectroscopy using viologens as reporter.
description This research presents the study towards a glucose biosensor using surface-enhanced Raman scattering (SERS) spectroscopy with benzyl viologen boronic acid (BVB1). According to previous studies, glucose has been difficult to detect by SERS due to its poor Raman cross section and its inability to absorb onto metallic surfaces. In this report, the study of indirect glucose detection via SERS is documented. Previous studies have shown the affinity of boronic acid towards monosaccharides. By incorporating the usage of Au substrates and a monolayer of BVB1, glucose molecules are captured by the boronic acid groups of BVB1, inducing conformation and orientation changes. Analysis of the SERS data collected suggests that glucose could be quantitatively detected in the physiological concentration range, with a linear predictive capability. The results obtained also fall within the acceptable regions of the Clarke error grid (Region A and B). The root-mean-square error of calibration (RMSEC) is approximately 41.24 mg/dl (2.29 mM) which is comparable to other studies. Data collected on the surface modification of silver/gold (bimetallic) film over nanospheres (FON) also demonstrated the theoretical mechanism of glucose sensing proposed by the group. Future works would include optimizing the sensing system by covalently binding BVB1 with the Au surface as well as using fiber optics, to produce a real time, in vivo glucose monitoring option that is minimally invasive.
author2 School of Chemical and Biomedical Engineering
author_facet School of Chemical and Biomedical Engineering
Cheng, Chun Chieh.
format Final Year Project
author Cheng, Chun Chieh.
author_sort Cheng, Chun Chieh.
title Quantitative glucose detection by surface-enhanced Raman spectroscopy using viologens as reporter.
title_short Quantitative glucose detection by surface-enhanced Raman spectroscopy using viologens as reporter.
title_full Quantitative glucose detection by surface-enhanced Raman spectroscopy using viologens as reporter.
title_fullStr Quantitative glucose detection by surface-enhanced Raman spectroscopy using viologens as reporter.
title_full_unstemmed Quantitative glucose detection by surface-enhanced Raman spectroscopy using viologens as reporter.
title_sort quantitative glucose detection by surface-enhanced raman spectroscopy using viologens as reporter.
publishDate 2010
url http://hdl.handle.net/10356/39833
_version_ 1759855147594285056