Design of micro motors for ingestible medical capsule
Capsule endoscopy is increasingly used in medical field for the diagnoses of gastrointestinal tract diseases, such as Crohn’s diease, gastric ulcers and colon cancer. The current capsule endoscopy has yet to provide medical professionals a complete and clear view of the digestive tract. The reason i...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
2010
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/40661 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-40661 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-406612023-03-04T19:30:44Z Design of micro motors for ingestible medical capsule Teoh, Boon Pin. Chen I-Ming School of Mechanical and Aerospace Engineering DRNTU::Engineering::Bioengineering DRNTU::Engineering::Mechanical engineering::Surgical assistive technology Capsule endoscopy is increasingly used in medical field for the diagnoses of gastrointestinal tract diseases, such as Crohn’s diease, gastric ulcers and colon cancer. The current capsule endoscopy has yet to provide medical professionals a complete and clear view of the digestive tract. The reason is because of the view angle of the camera is limited. To solve this problem, a micro motor is proposed to orient the camera so that it can capture a hemispherical view. In this study, piezoelectric actuator is selected to be the actuating element of the camera due to the various advantages that it has over other types of micro motors. The prototype design of the piezoelectric ultrasonic motor (USM) is also proposed in this project. In order to acquire the resonance frequencies and mode shapes of the piezoelectic actuator, modal analysis is carried out using ANSYS. To have feedback on the orientation of the rotor for the camera orientation, this project, a sensing system employing an optical sensor for the micro motor is suggested. Experiments are carried out to investigate the ability of the optical sensor to sense the spherical surface of the rotor. The results show that the optical sensing system proposed is able to trace the degree of rotation of a sphere of diameter 52.25mm about two principal axes which are perpendicular to each other. With the degree of rotation computed, we are able to determine the orientation of the camera. Bachelor of Engineering 2010-06-17T06:33:17Z 2010-06-17T06:33:17Z 2010 2010 Final Year Project (FYP) http://hdl.handle.net/10356/40661 en Nanyang Technological University 95 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Bioengineering DRNTU::Engineering::Mechanical engineering::Surgical assistive technology |
spellingShingle |
DRNTU::Engineering::Bioengineering DRNTU::Engineering::Mechanical engineering::Surgical assistive technology Teoh, Boon Pin. Design of micro motors for ingestible medical capsule |
description |
Capsule endoscopy is increasingly used in medical field for the diagnoses of gastrointestinal tract diseases, such as Crohn’s diease, gastric ulcers and colon cancer. The current capsule endoscopy has yet to provide medical professionals a complete and clear view of the digestive tract. The reason is because of the view angle of the camera is limited. To solve this problem, a micro motor is proposed to orient the camera so that it can capture a hemispherical view. In this study, piezoelectric actuator is selected to be the actuating element of the camera due to the various advantages that it has over other types of micro motors. The prototype design of the piezoelectric ultrasonic motor (USM) is also proposed in this project. In order to acquire the resonance frequencies and mode shapes of the piezoelectic actuator, modal analysis is carried out using ANSYS. To have feedback on the orientation of the rotor for the camera orientation, this project, a sensing system employing an optical sensor for the micro motor is suggested. Experiments are carried out to investigate the ability of the optical sensor to sense the spherical surface of the rotor. The results show that the optical sensing system proposed is able to trace the degree of rotation of a sphere of diameter 52.25mm about two principal axes which are perpendicular to each other. With the degree of rotation computed, we are able to determine the orientation of the camera. |
author2 |
Chen I-Ming |
author_facet |
Chen I-Ming Teoh, Boon Pin. |
format |
Final Year Project |
author |
Teoh, Boon Pin. |
author_sort |
Teoh, Boon Pin. |
title |
Design of micro motors for ingestible medical capsule |
title_short |
Design of micro motors for ingestible medical capsule |
title_full |
Design of micro motors for ingestible medical capsule |
title_fullStr |
Design of micro motors for ingestible medical capsule |
title_full_unstemmed |
Design of micro motors for ingestible medical capsule |
title_sort |
design of micro motors for ingestible medical capsule |
publishDate |
2010 |
url |
http://hdl.handle.net/10356/40661 |
_version_ |
1759854029839532032 |