Case records of pile foundation failures
Case records of pile foundation failures were highlighted in this project. They were classified into six main groups based on their major causes of failure : failures due to the absence of a proper site investigation, failures due to inadequate design, failures due to the effect of negative skin fri...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Theses and Dissertations |
Language: | English |
Published: |
2010
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/41667 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
Summary: | Case records of pile foundation failures were highlighted in this project. They were classified into six main groups based on their major causes of failure : failures due to the absence of a proper site investigation, failures due to inadequate design, failures due to the effect of negative skin friction, failures due to poor workmanship, failures due to the deterioration of piles and failures due to external influences. |
---|