Micro optofluidics combines microoptics with microfluidics to realize new functionalities and applications. Applications of this emerging field are new detection schemes for lab-on-a-chip platforms. With the help of the small equipments purchased in this supplementary equipment project, various aspe...

Full description

Saved in:
Bibliographic Details
Main Author: Nguyen, Nam Trung.
Other Authors: School of Mechanical and Aerospace Engineering
Format: Research Report
Language:English
Published: 2010
Subjects:
Online Access:http://hdl.handle.net/10356/42204
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-42204
record_format dspace
spelling sg-ntu-dr.10356-422042023-03-04T18:07:59Z Automatic system for micro optofluidic research Nguyen, Nam Trung. School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering::Fluid mechanics Micro optofluidics combines microoptics with microfluidics to realize new functionalities and applications. Applications of this emerging field are new detection schemes for lab-on-a-chip platforms. With the help of the small equipments purchased in this supplementary equipment project, various aspects of optofluidic were studied. An optofluidic switch that is capable of performing switching up to 1.67 Hz was developed. The various conditions that are necessary to switch the core flow were investigated. The project then moved on to characterize the wave guiding capability of a liquid claddingliquid core-liquid cladding system. The amount of light guided increases with larger core width and then saturates at high core flow rate. Based on the results of the above investigation, a novel core width sensor has been developed. The core width varies linearly with the light output intensity. As such the core width can be estimated by measuring the light output emitted from the core flow. Finally, the last phase of the project work on the dynamic manipulation of signal output by varying the core flow rate. Since the intensity of dye laser output with different core flow rate was characterized, it was possible to output desired voltage by executing the corresponding core flow rate. The ability of the system to output a sine wave, ramp and square wave were also examined and found to be able to trace the desired output with a certain amount of errors. However this serves as the first cut approximation for dynamic output manipulation. RG67/05 2010-09-30T03:58:40Z 2010-09-30T03:58:40Z 2007 2007 Research Report http://hdl.handle.net/10356/42204 en 70 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering::Fluid mechanics
spellingShingle DRNTU::Engineering::Mechanical engineering::Fluid mechanics
Nguyen, Nam Trung.
Automatic system for micro optofluidic research
description Micro optofluidics combines microoptics with microfluidics to realize new functionalities and applications. Applications of this emerging field are new detection schemes for lab-on-a-chip platforms. With the help of the small equipments purchased in this supplementary equipment project, various aspects of optofluidic were studied. An optofluidic switch that is capable of performing switching up to 1.67 Hz was developed. The various conditions that are necessary to switch the core flow were investigated. The project then moved on to characterize the wave guiding capability of a liquid claddingliquid core-liquid cladding system. The amount of light guided increases with larger core width and then saturates at high core flow rate. Based on the results of the above investigation, a novel core width sensor has been developed. The core width varies linearly with the light output intensity. As such the core width can be estimated by measuring the light output emitted from the core flow. Finally, the last phase of the project work on the dynamic manipulation of signal output by varying the core flow rate. Since the intensity of dye laser output with different core flow rate was characterized, it was possible to output desired voltage by executing the corresponding core flow rate. The ability of the system to output a sine wave, ramp and square wave were also examined and found to be able to trace the desired output with a certain amount of errors. However this serves as the first cut approximation for dynamic output manipulation.
author2 School of Mechanical and Aerospace Engineering
author_facet School of Mechanical and Aerospace Engineering
Nguyen, Nam Trung.
format Research Report
author Nguyen, Nam Trung.
author_sort Nguyen, Nam Trung.
title Automatic system for micro optofluidic research
title_short Automatic system for micro optofluidic research
title_full Automatic system for micro optofluidic research
title_fullStr Automatic system for micro optofluidic research
title_full_unstemmed Automatic system for micro optofluidic research
title_sort automatic system for micro optofluidic research
publishDate 2010
url http://hdl.handle.net/10356/42204
_version_ 1759855822338260992