Radar based sensing for healthcare monitoring

Continuous-Wave (CW) Doppler radar was deployed as the main subject in this case study. As shown in the recent advancement in technologies for signal processing, it can be seen that this technique is able to detect the movement of the whole body. For example in this case study, the focus will be on...

Full description

Saved in:
Bibliographic Details
Main Author: Chen, Evelyn Meiying.
Other Authors: Ser Wee
Format: Final Year Project
Language:English
Published: 2011
Subjects:
Online Access:http://hdl.handle.net/10356/45869
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-45869
record_format dspace
spelling sg-ntu-dr.10356-458692023-07-07T16:38:00Z Radar based sensing for healthcare monitoring Chen, Evelyn Meiying. Ser Wee School of Electrical and Electronic Engineering Centre for Signal Processing DRNTU::Engineering::Electrical and electronic engineering::Antennas, wave guides, microwaves, radar, radio Continuous-Wave (CW) Doppler radar was deployed as the main subject in this case study. As shown in the recent advancement in technologies for signal processing, it can be seen that this technique is able to detect the movement of the whole body. For example in this case study, the focus will be on the detection for individual heartbeats rate. In addition, the radar based sensing will research on the distance which is the limitation of the well proven technology such as the ECG. In this case study, a CW Doppler radar prototype was developed and ready for experimental test to evaluate on the results obtained. The author will address the various methods that will be used to capture the data using the CW Doppler radar. There are numerous methods to be deployed but in this case study; the methods selected for the extraction of data are the small angle approximation phase demodulation, the spectral estimation and the pruning of result. As mentioned above, the three methods algorithms will be written in MATLAB code as it is chosen as the software to run the simulation. The results of this case study will be based on these two requirements, the position of the subjects’ as well as the distance apart from the antenna to the subject’s chest level. Observation showed that the signals will fade at a longer distance regardless of the directions. In the overall conclusion, the author indicates that both the distance and the position play vital role in the measurement of the heartbeat. Bachelor of Engineering 2011-06-22T08:38:43Z 2011-06-22T08:38:43Z 2011 2011 Final Year Project (FYP) http://hdl.handle.net/10356/45869 en Nanyang Technological University 56 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Electrical and electronic engineering::Antennas, wave guides, microwaves, radar, radio
spellingShingle DRNTU::Engineering::Electrical and electronic engineering::Antennas, wave guides, microwaves, radar, radio
Chen, Evelyn Meiying.
Radar based sensing for healthcare monitoring
description Continuous-Wave (CW) Doppler radar was deployed as the main subject in this case study. As shown in the recent advancement in technologies for signal processing, it can be seen that this technique is able to detect the movement of the whole body. For example in this case study, the focus will be on the detection for individual heartbeats rate. In addition, the radar based sensing will research on the distance which is the limitation of the well proven technology such as the ECG. In this case study, a CW Doppler radar prototype was developed and ready for experimental test to evaluate on the results obtained. The author will address the various methods that will be used to capture the data using the CW Doppler radar. There are numerous methods to be deployed but in this case study; the methods selected for the extraction of data are the small angle approximation phase demodulation, the spectral estimation and the pruning of result. As mentioned above, the three methods algorithms will be written in MATLAB code as it is chosen as the software to run the simulation. The results of this case study will be based on these two requirements, the position of the subjects’ as well as the distance apart from the antenna to the subject’s chest level. Observation showed that the signals will fade at a longer distance regardless of the directions. In the overall conclusion, the author indicates that both the distance and the position play vital role in the measurement of the heartbeat.
author2 Ser Wee
author_facet Ser Wee
Chen, Evelyn Meiying.
format Final Year Project
author Chen, Evelyn Meiying.
author_sort Chen, Evelyn Meiying.
title Radar based sensing for healthcare monitoring
title_short Radar based sensing for healthcare monitoring
title_full Radar based sensing for healthcare monitoring
title_fullStr Radar based sensing for healthcare monitoring
title_full_unstemmed Radar based sensing for healthcare monitoring
title_sort radar based sensing for healthcare monitoring
publishDate 2011
url http://hdl.handle.net/10356/45869
_version_ 1772825479150043136