Due to the high difficulty in meeting the stringent requirement for precision, injection molding is still not widely used for the fabrication of microfluidic chip. This paper aims to investigate the effects of gate design and gate position have on the mold result. The objective is to produce a fl...

Full description

Saved in:
Bibliographic Details
Main Author: Low, Yi Sheng.
Other Authors: School of Mechanical and Aerospace Engineering
Format: Final Year Project
Language:English
Published: 2011
Subjects:
Online Access:http://hdl.handle.net/10356/46094
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-46094
record_format dspace
spelling sg-ntu-dr.10356-460942023-03-04T19:21:26Z CAE simulation study on the effects of gate types and gate positions for the application of moulding of polymer base micro fluidic chip Low, Yi Sheng. School of Mechanical and Aerospace Engineering A*STAR Singapore Institute of Manufacturing Technology Sylvie Castagne J.C. DRNTU::Engineering::Manufacturing::Polymers and plastics Due to the high difficulty in meeting the stringent requirement for precision, injection molding is still not widely used for the fabrication of microfluidic chip. This paper aims to investigate the effects of gate design and gate position have on the mold result. The objective is to produce a flat and precise microfluidic chip with minimal defects through the optimization of gate design and gate position. For the purpose of this study, two typical sizes of microfluidic chips (25X75mm and 50X75mm) are chosen. The polymer material used in this study was polycarbonate (PC) Lexan 121R (SABIC Innovative Plastics B.V.). Actual experiment of mold process is time consuming and expensive to conduct[1]. Hence, for this study, the molding process is simulated and optimized with CAE software Autodesk Moldflow in computer. Various gate positions and gate types are tested on the two sizes of microfluidic chip and critical results such as fill time and pressure at end of view are reviewed and investigated. This study shows that it is important to find a balance between the effect of flow direction of injection material and the distribution of pressure within the part as demonstrated in the gate position experiment. It is also concluded that using a wider fan gate will produced part with less warpage as a result of decrease in pressure difference. Using a wider fan gate also solve the problem with flow mark defect. Bachelor of Engineering (Mechanical Engineering) 2011-06-29T01:09:30Z 2011-06-29T01:09:30Z 2011 2011 Final Year Project (FYP) http://hdl.handle.net/10356/46094 en Nanyang Technological University 62 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Manufacturing::Polymers and plastics
spellingShingle DRNTU::Engineering::Manufacturing::Polymers and plastics
Low, Yi Sheng.
CAE simulation study on the effects of gate types and gate positions for the application of moulding of polymer base micro fluidic chip
description Due to the high difficulty in meeting the stringent requirement for precision, injection molding is still not widely used for the fabrication of microfluidic chip. This paper aims to investigate the effects of gate design and gate position have on the mold result. The objective is to produce a flat and precise microfluidic chip with minimal defects through the optimization of gate design and gate position. For the purpose of this study, two typical sizes of microfluidic chips (25X75mm and 50X75mm) are chosen. The polymer material used in this study was polycarbonate (PC) Lexan 121R (SABIC Innovative Plastics B.V.). Actual experiment of mold process is time consuming and expensive to conduct[1]. Hence, for this study, the molding process is simulated and optimized with CAE software Autodesk Moldflow in computer. Various gate positions and gate types are tested on the two sizes of microfluidic chip and critical results such as fill time and pressure at end of view are reviewed and investigated. This study shows that it is important to find a balance between the effect of flow direction of injection material and the distribution of pressure within the part as demonstrated in the gate position experiment. It is also concluded that using a wider fan gate will produced part with less warpage as a result of decrease in pressure difference. Using a wider fan gate also solve the problem with flow mark defect.
author2 School of Mechanical and Aerospace Engineering
author_facet School of Mechanical and Aerospace Engineering
Low, Yi Sheng.
format Final Year Project
author Low, Yi Sheng.
author_sort Low, Yi Sheng.
title CAE simulation study on the effects of gate types and gate positions for the application of moulding of polymer base micro fluidic chip
title_short CAE simulation study on the effects of gate types and gate positions for the application of moulding of polymer base micro fluidic chip
title_full CAE simulation study on the effects of gate types and gate positions for the application of moulding of polymer base micro fluidic chip
title_fullStr CAE simulation study on the effects of gate types and gate positions for the application of moulding of polymer base micro fluidic chip
title_full_unstemmed CAE simulation study on the effects of gate types and gate positions for the application of moulding of polymer base micro fluidic chip
title_sort cae simulation study on the effects of gate types and gate positions for the application of moulding of polymer base micro fluidic chip
publishDate 2011
url http://hdl.handle.net/10356/46094
_version_ 1759853524141735936