Optimization of ejector based multi-evaporator refrigeration system
Refrigerated shipping containers are widely used in transportation to provide customers with safe and high quality perishable goods. Driven primarily by the expansion of the chilled and quick-frozen foods market, refrigerated transport is a major economic player. As such, the growth for refrigerated...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
2012
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/49463 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-49463 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-494632023-07-07T16:55:53Z Optimization of ejector based multi-evaporator refrigeration system Teo, Jasmine Hui Hui. Cai Wenjian School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation Refrigerated shipping containers are widely used in transportation to provide customers with safe and high quality perishable goods. Driven primarily by the expansion of the chilled and quick-frozen foods market, refrigerated transport is a major economic player. As such, the growth for refrigerated shipping containers will continue to increase. Typically, evaporating temperatures of -30°C, -5°C and +7°C are required for freezing food, perishable food and space cooling respectively. An ejector based multi-evaporator refrigeration system (EMERS) which consists of a single refrigeration system with one compressor, two ejectors and three evaporators will be used for this project. The opening sizes of the EEVs, the compressor frequency and the condenser frequency will be adjusted to obtain the critical operating points of the system that will be needed for the optimization of the system. The experimental procedures and an analysis of the testing results will be included together with the suggestions for future improvements that can be made. Bachelor of Engineering 2012-05-18T08:47:01Z 2012-05-18T08:47:01Z 2012 2012 Final Year Project (FYP) http://hdl.handle.net/10356/49463 en Nanyang Technological University 59 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation |
spellingShingle |
DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation Teo, Jasmine Hui Hui. Optimization of ejector based multi-evaporator refrigeration system |
description |
Refrigerated shipping containers are widely used in transportation to provide customers with safe and high quality perishable goods. Driven primarily by the expansion of the chilled and quick-frozen foods market, refrigerated transport is a major economic player. As such, the growth for refrigerated shipping containers will continue to increase. Typically, evaporating temperatures of -30°C, -5°C and +7°C are required for freezing food, perishable food and space cooling respectively. An ejector based multi-evaporator refrigeration system (EMERS) which consists of a single refrigeration system with one compressor, two ejectors and three evaporators will be used for this project. The opening sizes of the EEVs, the compressor frequency and the condenser frequency will be adjusted to obtain the critical operating points of the system that will be needed for the optimization of the system. The experimental procedures and an analysis of the testing results will be included together with the suggestions for future improvements that can be made. |
author2 |
Cai Wenjian |
author_facet |
Cai Wenjian Teo, Jasmine Hui Hui. |
format |
Final Year Project |
author |
Teo, Jasmine Hui Hui. |
author_sort |
Teo, Jasmine Hui Hui. |
title |
Optimization of ejector based multi-evaporator refrigeration system |
title_short |
Optimization of ejector based multi-evaporator refrigeration system |
title_full |
Optimization of ejector based multi-evaporator refrigeration system |
title_fullStr |
Optimization of ejector based multi-evaporator refrigeration system |
title_full_unstemmed |
Optimization of ejector based multi-evaporator refrigeration system |
title_sort |
optimization of ejector based multi-evaporator refrigeration system |
publishDate |
2012 |
url |
http://hdl.handle.net/10356/49463 |
_version_ |
1772825595273543680 |