Short-term thermal comfort in different-sized air-conditioned lecture facilities
This report aims to evaluate the short-term thermal comfort of students inside different-sized air-conditioned teaching facilities, and to compare if there are significant differences of their perception to the actual temperature of the indoor facilities. Correlation of Sick Building Syndrome (SBS)...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
2012
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/49764 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-49764 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-497642023-03-03T17:17:35Z Short-term thermal comfort in different-sized air-conditioned lecture facilities Chan, Jun Peng. Chang Wei-Chung School of Civil and Environmental Engineering DRNTU::Engineering::Environmental engineering This report aims to evaluate the short-term thermal comfort of students inside different-sized air-conditioned teaching facilities, and to compare if there are significant differences of their perception to the actual temperature of the indoor facilities. Correlation of Sick Building Syndrome (SBS) with indoor carbon dioxide concentration level would be evaluated as well. Survey answers from the students and an accurate of measurement of both temperature and carbon dioxide concentration using TSI-OPC and IQM 60 machines would be used for discussion in this report. It was found that although most of the data obtained were within the limits of the guidelines set by ASHRAE, many respondents still felt cold and some had symptoms of SBS. The indoor concentration of carbon dioxide was found to have a close correlation with higher percentage of students suffering from SBS. Even though more than half of the correspondents felt that the temperature of teaching facilities were cold, only a minute percentage stated that they were uncomfortable as their overall comfort level. Recommendations to further this study were also made at the end of the report. Bachelor of Engineering (Environmental Engineering) 2012-05-24T02:37:06Z 2012-05-24T02:37:06Z 2012 2012 Final Year Project (FYP) http://hdl.handle.net/10356/49764 en Nanyang Technological University 38 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Environmental engineering |
spellingShingle |
DRNTU::Engineering::Environmental engineering Chan, Jun Peng. Short-term thermal comfort in different-sized air-conditioned lecture facilities |
description |
This report aims to evaluate the short-term thermal comfort of students inside different-sized air-conditioned teaching facilities, and to compare if there are significant differences of their perception to the actual temperature of the indoor facilities. Correlation of Sick Building Syndrome (SBS) with indoor carbon dioxide concentration level would be evaluated as well. Survey answers from the students and an accurate of measurement of both temperature and carbon dioxide concentration using TSI-OPC and IQM 60 machines would be used for discussion in this report. It was found that although most of the data obtained were within the limits of the guidelines set by ASHRAE, many respondents still felt cold and some had symptoms of SBS. The indoor concentration of carbon dioxide was found to have a close correlation with higher percentage of students suffering from SBS. Even though more than half of the correspondents felt that the temperature of teaching facilities were cold, only a minute percentage stated that they were uncomfortable as their overall comfort level. Recommendations to further this study were also made at the end of the report. |
author2 |
Chang Wei-Chung |
author_facet |
Chang Wei-Chung Chan, Jun Peng. |
format |
Final Year Project |
author |
Chan, Jun Peng. |
author_sort |
Chan, Jun Peng. |
title |
Short-term thermal comfort in different-sized air-conditioned lecture facilities |
title_short |
Short-term thermal comfort in different-sized air-conditioned lecture facilities |
title_full |
Short-term thermal comfort in different-sized air-conditioned lecture facilities |
title_fullStr |
Short-term thermal comfort in different-sized air-conditioned lecture facilities |
title_full_unstemmed |
Short-term thermal comfort in different-sized air-conditioned lecture facilities |
title_sort |
short-term thermal comfort in different-sized air-conditioned lecture facilities |
publishDate |
2012 |
url |
http://hdl.handle.net/10356/49764 |
_version_ |
1759856972462555136 |