Fluorescence diffuse optical imaging for small animal study.

The design of an all-optical anatomical co-registration for molecular imaging of small animals involves the consideration of several issues in regards of designing the experiment, optimization of data collected, economic and feasibility studies. Extensive literature review served as a crucial step t...

Full description

Saved in:
Bibliographic Details
Main Author: Lim, Shu Qiang.
Other Authors: Lee Kijoon
Format: Final Year Project
Language:English
Published: 2012
Subjects:
Online Access:http://hdl.handle.net/10356/49996
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-49996
record_format dspace
spelling sg-ntu-dr.10356-499962023-03-03T15:40:18Z Fluorescence diffuse optical imaging for small animal study. Lim, Shu Qiang. Lee Kijoon School of Chemical and Biomedical Engineering DRNTU::Science::Medicine::Optical instruments The design of an all-optical anatomical co-registration for molecular imaging of small animals involves the consideration of several issues in regards of designing the experiment, optimization of data collected, economic and feasibility studies. Extensive literature review served as a crucial step to gain meaningful information on up-to-date imaging techniques and process models. Not many works in the literature have used theories to study dynamic fluorescence molecular imaging (DFMI) technique. Only a handful of papers can be found but even these authors confined to only studying the feasibility of which. In this report, the author aims to devise a way to improve the interpretation of in vivo optical images of targeted contrast agent by a co-registered anatomical overlay of the major internal organs of the small animal. The proposed idea is to capture images of fluorescence of the major internal organs and overlap it with general view of the mice so as to obtain exactly co-registered anatomical overlay images. After which, principal component analysis (PCA) to outline each organ’s distinctive time course, will be performed Reports on the DFMI technique included the working principles, apparatus used, along with fine-tuning of the design. These consist of refining the accuracy of the image capturing processes and optimizing the various operating conditions. The study also includes considerations of alternatives to ensure effective operations of the DFMI technique. By verifying the accuracy of DFMI and PCA technique, this study has important implications to future clinical benefits in detecting tumours in human body. Bachelor of Engineering (Chemical and Biomolecular Engineering) 2012-05-28T06:27:44Z 2012-05-28T06:27:44Z 2012 2012 Final Year Project (FYP) http://hdl.handle.net/10356/49996 en Nanyang Technological University 67 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Science::Medicine::Optical instruments
spellingShingle DRNTU::Science::Medicine::Optical instruments
Lim, Shu Qiang.
Fluorescence diffuse optical imaging for small animal study.
description The design of an all-optical anatomical co-registration for molecular imaging of small animals involves the consideration of several issues in regards of designing the experiment, optimization of data collected, economic and feasibility studies. Extensive literature review served as a crucial step to gain meaningful information on up-to-date imaging techniques and process models. Not many works in the literature have used theories to study dynamic fluorescence molecular imaging (DFMI) technique. Only a handful of papers can be found but even these authors confined to only studying the feasibility of which. In this report, the author aims to devise a way to improve the interpretation of in vivo optical images of targeted contrast agent by a co-registered anatomical overlay of the major internal organs of the small animal. The proposed idea is to capture images of fluorescence of the major internal organs and overlap it with general view of the mice so as to obtain exactly co-registered anatomical overlay images. After which, principal component analysis (PCA) to outline each organ’s distinctive time course, will be performed Reports on the DFMI technique included the working principles, apparatus used, along with fine-tuning of the design. These consist of refining the accuracy of the image capturing processes and optimizing the various operating conditions. The study also includes considerations of alternatives to ensure effective operations of the DFMI technique. By verifying the accuracy of DFMI and PCA technique, this study has important implications to future clinical benefits in detecting tumours in human body.
author2 Lee Kijoon
author_facet Lee Kijoon
Lim, Shu Qiang.
format Final Year Project
author Lim, Shu Qiang.
author_sort Lim, Shu Qiang.
title Fluorescence diffuse optical imaging for small animal study.
title_short Fluorescence diffuse optical imaging for small animal study.
title_full Fluorescence diffuse optical imaging for small animal study.
title_fullStr Fluorescence diffuse optical imaging for small animal study.
title_full_unstemmed Fluorescence diffuse optical imaging for small animal study.
title_sort fluorescence diffuse optical imaging for small animal study.
publishDate 2012
url http://hdl.handle.net/10356/49996
_version_ 1759857739193909248