Optical fiber biosensor based on surface plasmon resonance.

In this report, we explore a surface plasmon resonance (SPR) fiber optics system that can be used as a convenient and cost-effective biosensor for the measuring of antibody binding activities. The phenomenon relies on the increase in refractive index when binding activities occur on the sensing inte...

Full description

Saved in:
Bibliographic Details
Main Author: Boo, Jia Liang.
Other Authors: Chan Chi Chiu
Format: Final Year Project
Language:English
Published: 2012
Subjects:
Online Access:http://hdl.handle.net/10356/50248
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-50248
record_format dspace
spelling sg-ntu-dr.10356-502482023-03-03T15:36:47Z Optical fiber biosensor based on surface plasmon resonance. Boo, Jia Liang. Chan Chi Chiu School of Chemical and Biomedical Engineering DRNTU::Science::Medicine::Biosensors In this report, we explore a surface plasmon resonance (SPR) fiber optics system that can be used as a convenient and cost-effective biosensor for the measuring of antibody binding activities. The phenomenon relies on the increase in refractive index when binding activities occur on the sensing interface, resulting in a red shift of the SPR wavelength. The fibers are created by splicing a length of photonic-crystal fiber (PCF) with collapsed regions in between multi-mode fibers (MMFs) and subsequently coating the PCF region with gold. The fabricated gold-coated fibers are then evaluated by using varying concentrations of sodium chloride solutions to test for their refractive index sensitivity. A linear relation is observed between the SPR wavelength shifts and the refractive indexes from 1.330 to 1.377. This result indicates that the fibers are suitable for bio-sensing purposes. For bio-sensing, binary mixtures of 11-mercaptoundecanoic acid (MUA) and 6- mercaptohexanol (C6OH) are adsorbed onto the gold-coated fibers via Au-S bonds to produce mixed self-assembled monolayers (SAMs). This allows for the efficient covalent binding of Protein G (PrG), which in turn has a high affinity for the immobilization of IgG. Varying concentrations of anti-IgG is quantified by binding them to the IgG and subsequently measuring the SPR wavelength shifts of the samples. The results obtained indicate that the system can be used to effectively quantify anti-IgG concentrations varying from 1mg/L to 30mg/L. Bachelor of Engineering (Chemical and Biomolecular Engineering) 2012-05-31T03:53:48Z 2012-05-31T03:53:48Z 2012 2012 Final Year Project (FYP) http://hdl.handle.net/10356/50248 en Nanyang Technological University 59 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Science::Medicine::Biosensors
spellingShingle DRNTU::Science::Medicine::Biosensors
Boo, Jia Liang.
Optical fiber biosensor based on surface plasmon resonance.
description In this report, we explore a surface plasmon resonance (SPR) fiber optics system that can be used as a convenient and cost-effective biosensor for the measuring of antibody binding activities. The phenomenon relies on the increase in refractive index when binding activities occur on the sensing interface, resulting in a red shift of the SPR wavelength. The fibers are created by splicing a length of photonic-crystal fiber (PCF) with collapsed regions in between multi-mode fibers (MMFs) and subsequently coating the PCF region with gold. The fabricated gold-coated fibers are then evaluated by using varying concentrations of sodium chloride solutions to test for their refractive index sensitivity. A linear relation is observed between the SPR wavelength shifts and the refractive indexes from 1.330 to 1.377. This result indicates that the fibers are suitable for bio-sensing purposes. For bio-sensing, binary mixtures of 11-mercaptoundecanoic acid (MUA) and 6- mercaptohexanol (C6OH) are adsorbed onto the gold-coated fibers via Au-S bonds to produce mixed self-assembled monolayers (SAMs). This allows for the efficient covalent binding of Protein G (PrG), which in turn has a high affinity for the immobilization of IgG. Varying concentrations of anti-IgG is quantified by binding them to the IgG and subsequently measuring the SPR wavelength shifts of the samples. The results obtained indicate that the system can be used to effectively quantify anti-IgG concentrations varying from 1mg/L to 30mg/L.
author2 Chan Chi Chiu
author_facet Chan Chi Chiu
Boo, Jia Liang.
format Final Year Project
author Boo, Jia Liang.
author_sort Boo, Jia Liang.
title Optical fiber biosensor based on surface plasmon resonance.
title_short Optical fiber biosensor based on surface plasmon resonance.
title_full Optical fiber biosensor based on surface plasmon resonance.
title_fullStr Optical fiber biosensor based on surface plasmon resonance.
title_full_unstemmed Optical fiber biosensor based on surface plasmon resonance.
title_sort optical fiber biosensor based on surface plasmon resonance.
publishDate 2012
url http://hdl.handle.net/10356/50248
_version_ 1759855788551045120