Sensitivity characteristics of high-birefringence sagnac interferometer.
The sensitivity characteristics of the sensors based on high-birefringence Sagnac interferometer are theoretically analyzed and experimentally verified. We analyze the sensitivity of the sensor in terms of the frequency instead of the wavelength of the light to avoid any approximation and find that...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Theses and Dissertations |
Language: | English |
Published: |
2012
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/50529 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-50529 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-505292023-03-03T16:05:07Z Sensitivity characteristics of high-birefringence sagnac interferometer. Liang, Ziyang. Chan Chi Chiu School of Chemical and Biomedical Engineering DRNTU::Engineering::Chemical engineering The sensitivity characteristics of the sensors based on high-birefringence Sagnac interferometer are theoretically analyzed and experimentally verified. We analyze the sensitivity of the sensor in terms of the frequency instead of the wavelength of the light to avoid any approximation and find that the sensitivity can be improved by reducing the length of HBF. The strain, mechanical load and temperature-based experiments are carried out and their experimental results agree well with the theoretical results. Master of Science 2012-06-11T08:32:27Z 2012-06-11T08:32:27Z 2012 2012 Thesis http://hdl.handle.net/10356/50529 en 42 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Chemical engineering |
spellingShingle |
DRNTU::Engineering::Chemical engineering Liang, Ziyang. Sensitivity characteristics of high-birefringence sagnac interferometer. |
description |
The sensitivity characteristics of the sensors based on high-birefringence Sagnac interferometer are theoretically analyzed and experimentally verified. We analyze the sensitivity of the sensor in terms of the frequency instead of the wavelength of the light to avoid any approximation and find that the sensitivity can be improved by reducing the length of HBF. The strain, mechanical load and temperature-based experiments are carried out and their experimental results agree well with the theoretical results. |
author2 |
Chan Chi Chiu |
author_facet |
Chan Chi Chiu Liang, Ziyang. |
format |
Theses and Dissertations |
author |
Liang, Ziyang. |
author_sort |
Liang, Ziyang. |
title |
Sensitivity characteristics of high-birefringence sagnac interferometer. |
title_short |
Sensitivity characteristics of high-birefringence sagnac interferometer. |
title_full |
Sensitivity characteristics of high-birefringence sagnac interferometer. |
title_fullStr |
Sensitivity characteristics of high-birefringence sagnac interferometer. |
title_full_unstemmed |
Sensitivity characteristics of high-birefringence sagnac interferometer. |
title_sort |
sensitivity characteristics of high-birefringence sagnac interferometer. |
publishDate |
2012 |
url |
http://hdl.handle.net/10356/50529 |
_version_ |
1759856654000586752 |