Sensitivity characteristics of high-birefringence sagnac interferometer.

The sensitivity characteristics of the sensors based on high-birefringence Sagnac interferometer are theoretically analyzed and experimentally verified. We analyze the sensitivity of the sensor in terms of the frequency instead of the wavelength of the light to avoid any approximation and find that...

Full description

Saved in:
Bibliographic Details
Main Author: Liang, Ziyang.
Other Authors: Chan Chi Chiu
Format: Theses and Dissertations
Language:English
Published: 2012
Subjects:
Online Access:http://hdl.handle.net/10356/50529
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-50529
record_format dspace
spelling sg-ntu-dr.10356-505292023-03-03T16:05:07Z Sensitivity characteristics of high-birefringence sagnac interferometer. Liang, Ziyang. Chan Chi Chiu School of Chemical and Biomedical Engineering DRNTU::Engineering::Chemical engineering The sensitivity characteristics of the sensors based on high-birefringence Sagnac interferometer are theoretically analyzed and experimentally verified. We analyze the sensitivity of the sensor in terms of the frequency instead of the wavelength of the light to avoid any approximation and find that the sensitivity can be improved by reducing the length of HBF. The strain, mechanical load and temperature-based experiments are carried out and their experimental results agree well with the theoretical results. Master of Science 2012-06-11T08:32:27Z 2012-06-11T08:32:27Z 2012 2012 Thesis http://hdl.handle.net/10356/50529 en 42 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Chemical engineering
spellingShingle DRNTU::Engineering::Chemical engineering
Liang, Ziyang.
Sensitivity characteristics of high-birefringence sagnac interferometer.
description The sensitivity characteristics of the sensors based on high-birefringence Sagnac interferometer are theoretically analyzed and experimentally verified. We analyze the sensitivity of the sensor in terms of the frequency instead of the wavelength of the light to avoid any approximation and find that the sensitivity can be improved by reducing the length of HBF. The strain, mechanical load and temperature-based experiments are carried out and their experimental results agree well with the theoretical results.
author2 Chan Chi Chiu
author_facet Chan Chi Chiu
Liang, Ziyang.
format Theses and Dissertations
author Liang, Ziyang.
author_sort Liang, Ziyang.
title Sensitivity characteristics of high-birefringence sagnac interferometer.
title_short Sensitivity characteristics of high-birefringence sagnac interferometer.
title_full Sensitivity characteristics of high-birefringence sagnac interferometer.
title_fullStr Sensitivity characteristics of high-birefringence sagnac interferometer.
title_full_unstemmed Sensitivity characteristics of high-birefringence sagnac interferometer.
title_sort sensitivity characteristics of high-birefringence sagnac interferometer.
publishDate 2012
url http://hdl.handle.net/10356/50529
_version_ 1759856654000586752