Development of cerebral artery mimicking system

To understand the characteristics of blood flow within the cerebral artery, many kinds of models were presented to mimic the cerebral artery. Some models are based on in vivo models which relates to the surgical operations on animal brains and other models are computed mathematically with the aid...

Full description

Saved in:
Bibliographic Details
Main Author: Muhammad Sazli Mohamed Saleh.
Other Authors: School of Mechanical and Aerospace Engineering
Format: Final Year Project
Language:English
Published: 2013
Subjects:
Online Access:http://hdl.handle.net/10356/50988
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-50988
record_format dspace
spelling sg-ntu-dr.10356-509882023-03-04T18:32:42Z Development of cerebral artery mimicking system Muhammad Sazli Mohamed Saleh. School of Mechanical and Aerospace Engineering Zhou Yufeng DRNTU::Engineering::Mechanical engineering DRNTU::Engineering::Bioengineering To understand the characteristics of blood flow within the cerebral artery, many kinds of models were presented to mimic the cerebral artery. Some models are based on in vivo models which relates to the surgical operations on animal brains and other models are computed mathematically with the aid of computer software. However, not many researches are performing studies on in vitro mechanical models. Studies have also shown the inaccuracies of using animal based models to experiment the characteristics of blood flow within the cerebral artery system. Such animal based models cannot be comparable to the human physiological cerebral anatomy. The aim of this report is to identify the blood flow characteristics in the cerebral artery, more specifically in the region of Circle of Willis, by using a mechanical model and obtaining results for investigations. Certain experimental parameters are used to further understand the flow characteristics such as the presence of occlusion within the segments of the cerebral artery network and also the velocity in each segment of the cerebral artery model. In conclusion, the highest flow rate (an increase of more than 200%) was observed at the Posterior Cerebral Communicating Artery segment when occlusion was present in either the Anterior Cerebral Artery or the Posterior Cerebral Artery. Therefore, further investigations can be done to remedy such occlusion hazard. The cerebral artery brain tissue mimicking model created in this experiment can be used as an experimental aid for non-invasive method of treatment. The reliance of focus ultrasound can be tested and maybe used to substitute for current treatment procedures. Bachelor of Engineering (Mechanical Engineering) 2013-01-02T06:13:32Z 2013-01-02T06:13:32Z 2012 2012 Final Year Project (FYP) http://hdl.handle.net/10356/50988 en Nanyang Technological University 60 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering
DRNTU::Engineering::Bioengineering
spellingShingle DRNTU::Engineering::Mechanical engineering
DRNTU::Engineering::Bioengineering
Muhammad Sazli Mohamed Saleh.
Development of cerebral artery mimicking system
description To understand the characteristics of blood flow within the cerebral artery, many kinds of models were presented to mimic the cerebral artery. Some models are based on in vivo models which relates to the surgical operations on animal brains and other models are computed mathematically with the aid of computer software. However, not many researches are performing studies on in vitro mechanical models. Studies have also shown the inaccuracies of using animal based models to experiment the characteristics of blood flow within the cerebral artery system. Such animal based models cannot be comparable to the human physiological cerebral anatomy. The aim of this report is to identify the blood flow characteristics in the cerebral artery, more specifically in the region of Circle of Willis, by using a mechanical model and obtaining results for investigations. Certain experimental parameters are used to further understand the flow characteristics such as the presence of occlusion within the segments of the cerebral artery network and also the velocity in each segment of the cerebral artery model. In conclusion, the highest flow rate (an increase of more than 200%) was observed at the Posterior Cerebral Communicating Artery segment when occlusion was present in either the Anterior Cerebral Artery or the Posterior Cerebral Artery. Therefore, further investigations can be done to remedy such occlusion hazard. The cerebral artery brain tissue mimicking model created in this experiment can be used as an experimental aid for non-invasive method of treatment. The reliance of focus ultrasound can be tested and maybe used to substitute for current treatment procedures.
author2 School of Mechanical and Aerospace Engineering
author_facet School of Mechanical and Aerospace Engineering
Muhammad Sazli Mohamed Saleh.
format Final Year Project
author Muhammad Sazli Mohamed Saleh.
author_sort Muhammad Sazli Mohamed Saleh.
title Development of cerebral artery mimicking system
title_short Development of cerebral artery mimicking system
title_full Development of cerebral artery mimicking system
title_fullStr Development of cerebral artery mimicking system
title_full_unstemmed Development of cerebral artery mimicking system
title_sort development of cerebral artery mimicking system
publishDate 2013
url http://hdl.handle.net/10356/50988
_version_ 1759853993324969984