Studies on energy performance of high ambient temperature green data centres

This report presents a simulation of cooling in data center within the context of Singapore’s climate. The modelling and simulation of the data center is executed with TRNSYS. The programme will carry out year-round simulations based on recorded local weather data. A data center space of 4000m³ w...

Full description

Saved in:
Bibliographic Details
Main Author: Chua, Wee Jian.
Other Authors: Wong Yew Wah
Format: Final Year Project
Language:English
Published: 2013
Subjects:
Online Access:http://hdl.handle.net/10356/51021
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-51021
record_format dspace
spelling sg-ntu-dr.10356-510212023-03-04T18:29:56Z Studies on energy performance of high ambient temperature green data centres Chua, Wee Jian. Wong Yew Wah School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering::Alternative, renewable energy sources This report presents a simulation of cooling in data center within the context of Singapore’s climate. The modelling and simulation of the data center is executed with TRNSYS. The programme will carry out year-round simulations based on recorded local weather data. A data center space of 4000m³ was set up and studies were carried out to understand and select the potential energy saving methodologies available. All simulation parameters are within specifications of ASHRAE’s whitepaper titled ‘2011 Thermal Guidelines for Data Processing Environment – Expanded Data Center Classes and Usage Guidance’. The project first explores the suitability of an air-cooled system versus a water-cooled system, which is followed by the viability of adding an economizer into the conventional cooling system. Studies were also conducted to explore the suitability of a water-side economizer versus an air-side economizer. The results show that water-cooled systems are more efficient due to its higher efficiency rating. It also discovered that water-side economizers are not suitable for Singapore’s weather context as it operates best in areas with wet bulb temperatures of 12.8oC for more than 3000 hours per year. On the contrary, air-side economizers are a viable option as they managed to clock 537 hours to produce a 6.21% energy savings against the energy consumption of a whole year (8640 hours). The report also compares the PUE (Power Usage Effectiveness) of the conventional cooling system with the economizer-added system. It is found out that the PUE manages to achieve a rating of 1.83. Finally, the report will lead to the derivation of the optimized HVAC set-up with potential energy savings of up to 37% when compared to a conventional HVAC set-up. Bachelor of Engineering (Mechanical Engineering) 2013-01-03T01:45:23Z 2013-01-03T01:45:23Z 2012 2012 Final Year Project (FYP) http://hdl.handle.net/10356/51021 en Nanyang Technological University 53 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering::Alternative, renewable energy sources
spellingShingle DRNTU::Engineering::Mechanical engineering::Alternative, renewable energy sources
Chua, Wee Jian.
Studies on energy performance of high ambient temperature green data centres
description This report presents a simulation of cooling in data center within the context of Singapore’s climate. The modelling and simulation of the data center is executed with TRNSYS. The programme will carry out year-round simulations based on recorded local weather data. A data center space of 4000m³ was set up and studies were carried out to understand and select the potential energy saving methodologies available. All simulation parameters are within specifications of ASHRAE’s whitepaper titled ‘2011 Thermal Guidelines for Data Processing Environment – Expanded Data Center Classes and Usage Guidance’. The project first explores the suitability of an air-cooled system versus a water-cooled system, which is followed by the viability of adding an economizer into the conventional cooling system. Studies were also conducted to explore the suitability of a water-side economizer versus an air-side economizer. The results show that water-cooled systems are more efficient due to its higher efficiency rating. It also discovered that water-side economizers are not suitable for Singapore’s weather context as it operates best in areas with wet bulb temperatures of 12.8oC for more than 3000 hours per year. On the contrary, air-side economizers are a viable option as they managed to clock 537 hours to produce a 6.21% energy savings against the energy consumption of a whole year (8640 hours). The report also compares the PUE (Power Usage Effectiveness) of the conventional cooling system with the economizer-added system. It is found out that the PUE manages to achieve a rating of 1.83. Finally, the report will lead to the derivation of the optimized HVAC set-up with potential energy savings of up to 37% when compared to a conventional HVAC set-up.
author2 Wong Yew Wah
author_facet Wong Yew Wah
Chua, Wee Jian.
format Final Year Project
author Chua, Wee Jian.
author_sort Chua, Wee Jian.
title Studies on energy performance of high ambient temperature green data centres
title_short Studies on energy performance of high ambient temperature green data centres
title_full Studies on energy performance of high ambient temperature green data centres
title_fullStr Studies on energy performance of high ambient temperature green data centres
title_full_unstemmed Studies on energy performance of high ambient temperature green data centres
title_sort studies on energy performance of high ambient temperature green data centres
publishDate 2013
url http://hdl.handle.net/10356/51021
_version_ 1759858038797238272