Safety assessment of cracked tubular Y-joints using failure assessment diagram (FAD) method

This report covers the Failure Assessment Diagram (FAD) analysis of cracked circular hollow section (CHS) Y-joints according to British Standard BS 7910 FAD level 3C assessment criteria.Firstly, 3D mesh models of the CHS Y-joins ware generated with a surface crack of specific depth and length. Ax...

Full description

Saved in:
Bibliographic Details
Main Author: Gao, Zhe.
Other Authors: Lie Seng Tjhen
Format: Final Year Project
Language:English
Published: 2013
Subjects:
Online Access:http://hdl.handle.net/10356/52816
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English