Hydrodynamic bearings have been widely used in many industries for a long time. The principles of the hydrodynamic bearing are that fluid is pumped into the inner surface of the bearing, forming a lubricating wedge around or under the shaft. Its simplicity and low cost of production and low maintena...

Full description

Saved in:
Bibliographic Details
Main Author: Lee, Jian Ming.
Other Authors: Chan Weng Kong
Format: Final Year Project
Language:English
Published: 2013
Subjects:
Online Access:http://hdl.handle.net/10356/53291
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-53291
record_format dspace
spelling sg-ntu-dr.10356-532912023-03-04T19:17:59Z Investigation of passive bearing for biomedical applications Lee, Jian Ming. Chan Weng Kong School of Mechanical and Aerospace Engineering DRNTU::Engineering Hydrodynamic bearings have been widely used in many industries for a long time. The principles of the hydrodynamic bearing are that fluid is pumped into the inner surface of the bearing, forming a lubricating wedge around or under the shaft. Its simplicity and low cost of production and low maintenance makes it popular with design engineers. In modern technology today, hydrodynamic bearings are currently used in the biomedical and bioengineering industries. In this project, theoretical equations used by many researchers are being investigated and analyzed. The theory behind the spiral groove bearing or SGB is explained and the formula is investigated numerically. Derivations of pressure rise across the SGB were presented and the result graph plotted. Parameters such as the spiral angle, film height to groove height ratio, ridge width to groove width ratio, inner radius to outer radius ratio and the number of grooves were analyzed. Using the results obtained from the different variations, the effects were analyzed and optimum values for the pressure across the SGB were obtained. Results taken from the theoretical modeling by varying parameters such as film height and grooves, coupled with the results from past CFD simulations concluded that the equations had difference in the pressure rise across the SGB due to inertia effects that were not accounted for in the theoretical formulation. Another reason for the difference in theoretical and CFD results was that the pressure varies linearly at the entrance of the groove and ridge might not be accurate. Bachelor of Engineering (Mechanical Engineering) 2013-05-31T04:05:00Z 2013-05-31T04:05:00Z 2013 2013 Final Year Project (FYP) http://hdl.handle.net/10356/53291 en Nanyang Technological University 84 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering
spellingShingle DRNTU::Engineering
Lee, Jian Ming.
Investigation of passive bearing for biomedical applications
description Hydrodynamic bearings have been widely used in many industries for a long time. The principles of the hydrodynamic bearing are that fluid is pumped into the inner surface of the bearing, forming a lubricating wedge around or under the shaft. Its simplicity and low cost of production and low maintenance makes it popular with design engineers. In modern technology today, hydrodynamic bearings are currently used in the biomedical and bioengineering industries. In this project, theoretical equations used by many researchers are being investigated and analyzed. The theory behind the spiral groove bearing or SGB is explained and the formula is investigated numerically. Derivations of pressure rise across the SGB were presented and the result graph plotted. Parameters such as the spiral angle, film height to groove height ratio, ridge width to groove width ratio, inner radius to outer radius ratio and the number of grooves were analyzed. Using the results obtained from the different variations, the effects were analyzed and optimum values for the pressure across the SGB were obtained. Results taken from the theoretical modeling by varying parameters such as film height and grooves, coupled with the results from past CFD simulations concluded that the equations had difference in the pressure rise across the SGB due to inertia effects that were not accounted for in the theoretical formulation. Another reason for the difference in theoretical and CFD results was that the pressure varies linearly at the entrance of the groove and ridge might not be accurate.
author2 Chan Weng Kong
author_facet Chan Weng Kong
Lee, Jian Ming.
format Final Year Project
author Lee, Jian Ming.
author_sort Lee, Jian Ming.
title Investigation of passive bearing for biomedical applications
title_short Investigation of passive bearing for biomedical applications
title_full Investigation of passive bearing for biomedical applications
title_fullStr Investigation of passive bearing for biomedical applications
title_full_unstemmed Investigation of passive bearing for biomedical applications
title_sort investigation of passive bearing for biomedical applications
publishDate 2013
url http://hdl.handle.net/10356/53291
_version_ 1759858161434492928