IGRT couch study with AcurosXB using cylindrical diode phantom.

As arc therapy treatment like RapidArc requires the beam to pass through the treatment couch at various angles, it is important to determine the effect of the couch in the treatment plans and hence apply to determine a correction to it. The image guided radiotherapy (IGRT) couch contains th...

Full description

Saved in:
Bibliographic Details
Main Author: Chew, Melvin Ming Long.
Other Authors: Jacek Maciej Zurada
Format: Final Year Project
Language:English
Published: 2013
Subjects:
Online Access:http://hdl.handle.net/10356/53670
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-53670
record_format dspace
spelling sg-ntu-dr.10356-536702023-02-28T23:16:49Z IGRT couch study with AcurosXB using cylindrical diode phantom. Chew, Melvin Ming Long. Jacek Maciej Zurada School of Physical and Mathematical Sciences National Cancer Centre Singapore Lee Cheow Lei James DRNTU::Science As arc therapy treatment like RapidArc requires the beam to pass through the treatment couch at various angles, it is important to determine the effect of the couch in the treatment plans and hence apply to determine a correction to it. The image guided radiotherapy (IGRT) couch contains three different sections with three different thicknesses in the couch. The IGRT couch cross section has two structures, the interior and the surface structures. In a previous study the Hounsfield Unit (HU) characterization for a Monte Carlo model was found to have -700 HU for the surface structure and -960HU for the interior structure of the IGRT couch. The objectives of this study are to verify that the HU characterization used by the Monte Carlo model is also suitable for use in a AcurosXB algorithm model, also to provide a couch correction on quality assurance (QA) results for AcurosXB dose calculation for RapidArc Treatments. A cylindrical diode array phantom (ArcCheck, Sun Nuclear Corp., USA) was used in this study. The Arc Check was placed in the thick part of the couch. Static beams at different gantry angles and field sizes were measures and also used in the treatment planning system to verify if the HU characterization for AcurosXB. Comparison was done by using different sets of HU values for the surface and interior of the IGRT couch. To determine the couch correction, static beams were measured at sufficiently small gantry angle intervals to determine the threshold angle where the gamma passing rates start to decrease. Results have shown that the set of HU values of -400HU and polystyrene material, assigned for the couch surface is accurate for use in Acuros. Results showed that when using the optimal couch setting, at couch directional angles a higher gamma pass rate and lower dose difference were achieved. In general the results from the criterions gamma passing rates and dose differences were in good agreement. Bachelor of Science in Physics 2013-06-06T08:39:43Z 2013-06-06T08:39:43Z 2013 2013 Final Year Project (FYP) http://hdl.handle.net/10356/53670 en 83 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Science
spellingShingle DRNTU::Science
Chew, Melvin Ming Long.
IGRT couch study with AcurosXB using cylindrical diode phantom.
description As arc therapy treatment like RapidArc requires the beam to pass through the treatment couch at various angles, it is important to determine the effect of the couch in the treatment plans and hence apply to determine a correction to it. The image guided radiotherapy (IGRT) couch contains three different sections with three different thicknesses in the couch. The IGRT couch cross section has two structures, the interior and the surface structures. In a previous study the Hounsfield Unit (HU) characterization for a Monte Carlo model was found to have -700 HU for the surface structure and -960HU for the interior structure of the IGRT couch. The objectives of this study are to verify that the HU characterization used by the Monte Carlo model is also suitable for use in a AcurosXB algorithm model, also to provide a couch correction on quality assurance (QA) results for AcurosXB dose calculation for RapidArc Treatments. A cylindrical diode array phantom (ArcCheck, Sun Nuclear Corp., USA) was used in this study. The Arc Check was placed in the thick part of the couch. Static beams at different gantry angles and field sizes were measures and also used in the treatment planning system to verify if the HU characterization for AcurosXB. Comparison was done by using different sets of HU values for the surface and interior of the IGRT couch. To determine the couch correction, static beams were measured at sufficiently small gantry angle intervals to determine the threshold angle where the gamma passing rates start to decrease. Results have shown that the set of HU values of -400HU and polystyrene material, assigned for the couch surface is accurate for use in Acuros. Results showed that when using the optimal couch setting, at couch directional angles a higher gamma pass rate and lower dose difference were achieved. In general the results from the criterions gamma passing rates and dose differences were in good agreement.
author2 Jacek Maciej Zurada
author_facet Jacek Maciej Zurada
Chew, Melvin Ming Long.
format Final Year Project
author Chew, Melvin Ming Long.
author_sort Chew, Melvin Ming Long.
title IGRT couch study with AcurosXB using cylindrical diode phantom.
title_short IGRT couch study with AcurosXB using cylindrical diode phantom.
title_full IGRT couch study with AcurosXB using cylindrical diode phantom.
title_fullStr IGRT couch study with AcurosXB using cylindrical diode phantom.
title_full_unstemmed IGRT couch study with AcurosXB using cylindrical diode phantom.
title_sort igrt couch study with acurosxb using cylindrical diode phantom.
publishDate 2013
url http://hdl.handle.net/10356/53670
_version_ 1759856778661593088