Development of a new steel profile deck for composite floor system

Generally for ordinary profile steel deck, there are four possible modes of failure which are the bending moment failure at mid-span, shear failure at end support, web crippling and section failure over internal support under combined action of shear force and hogging moment. However, for this proje...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Lim, Jia Ying.
مؤلفون آخرون: Chiew Sing Ping
التنسيق: Final Year Project
اللغة:English
منشور في: 2013
الموضوعات:
الوصول للمادة أونلاين:http://hdl.handle.net/10356/53893
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
المؤسسة: Nanyang Technological University
اللغة: English
id sg-ntu-dr.10356-53893
record_format dspace
spelling sg-ntu-dr.10356-538932023-03-03T16:53:31Z Development of a new steel profile deck for composite floor system Lim, Jia Ying. Chiew Sing Ping School of Civil and Environmental Engineering DRNTU::Engineering Generally for ordinary profile steel deck, there are four possible modes of failure which are the bending moment failure at mid-span, shear failure at end support, web crippling and section failure over internal support under combined action of shear force and hogging moment. However, for this project, the author and her partner will be investigating on a newly developed steel deck using different codes of practice that has just been implemented recently by Building Construction Authority (BCA) in 2010. Hence, this report aims to investigate the behavior of the various modes of failure on a newly developed embossed profile steel deck through experimental studies and data analysis based on BS EN 1993-1-3 (Eurocode 3). The author and her partner conducted 14 specimens of steel deck profile with different thickness of 0.75mm and 1.0mm. These specimens are tested under static loading for the respective failure mode in which the applied load capacity is increased until failure occurs. The load-deflection characteristic of the profile steel decks is measured by the use of linear variable displacement transducer (LVDTs). After examining the failure load and deflection values, the graph of load versus deflection were then plotted out for data analysis. All the test setups were designed and carried out in accordance to the Eurocode 3 and hence different dimensions of the profile steel deck is required to fulfill the Eurocode standards. In order to facilitate the computation of the theoretical values, an excel template is created. With respect to the code predictions and calculations, the Eurocode 3 in general provides a lower theoretical value as compared to the experimental values. Hence, this shows that Eurocode is generally conservative and therefore safe for use. However, the experimental result of the failure loads show variations when compared to the theoretical values predicted from the Eurocode 3. This may be due to some of the limitation and experimental errors that may have occurred during the experiment which will be further elaborated in the report. In conjunction of this report, it is to be viewed entirely with another report under the same project ST19AB prepared by the author’s partner, Tan Lai Hui, on the similar analysis based on Eurocode 3 with focus on the web crippling failure and section failure over internal support under combines action of shear force and hogging moment. Bachelor of Engineering (Civil) 2013-06-10T03:09:59Z 2013-06-10T03:09:59Z 2013 2013 Final Year Project (FYP) http://hdl.handle.net/10356/53893 en Nanyang Technological University 53 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering
spellingShingle DRNTU::Engineering
Lim, Jia Ying.
Development of a new steel profile deck for composite floor system
description Generally for ordinary profile steel deck, there are four possible modes of failure which are the bending moment failure at mid-span, shear failure at end support, web crippling and section failure over internal support under combined action of shear force and hogging moment. However, for this project, the author and her partner will be investigating on a newly developed steel deck using different codes of practice that has just been implemented recently by Building Construction Authority (BCA) in 2010. Hence, this report aims to investigate the behavior of the various modes of failure on a newly developed embossed profile steel deck through experimental studies and data analysis based on BS EN 1993-1-3 (Eurocode 3). The author and her partner conducted 14 specimens of steel deck profile with different thickness of 0.75mm and 1.0mm. These specimens are tested under static loading for the respective failure mode in which the applied load capacity is increased until failure occurs. The load-deflection characteristic of the profile steel decks is measured by the use of linear variable displacement transducer (LVDTs). After examining the failure load and deflection values, the graph of load versus deflection were then plotted out for data analysis. All the test setups were designed and carried out in accordance to the Eurocode 3 and hence different dimensions of the profile steel deck is required to fulfill the Eurocode standards. In order to facilitate the computation of the theoretical values, an excel template is created. With respect to the code predictions and calculations, the Eurocode 3 in general provides a lower theoretical value as compared to the experimental values. Hence, this shows that Eurocode is generally conservative and therefore safe for use. However, the experimental result of the failure loads show variations when compared to the theoretical values predicted from the Eurocode 3. This may be due to some of the limitation and experimental errors that may have occurred during the experiment which will be further elaborated in the report. In conjunction of this report, it is to be viewed entirely with another report under the same project ST19AB prepared by the author’s partner, Tan Lai Hui, on the similar analysis based on Eurocode 3 with focus on the web crippling failure and section failure over internal support under combines action of shear force and hogging moment.
author2 Chiew Sing Ping
author_facet Chiew Sing Ping
Lim, Jia Ying.
format Final Year Project
author Lim, Jia Ying.
author_sort Lim, Jia Ying.
title Development of a new steel profile deck for composite floor system
title_short Development of a new steel profile deck for composite floor system
title_full Development of a new steel profile deck for composite floor system
title_fullStr Development of a new steel profile deck for composite floor system
title_full_unstemmed Development of a new steel profile deck for composite floor system
title_sort development of a new steel profile deck for composite floor system
publishDate 2013
url http://hdl.handle.net/10356/53893
_version_ 1759855720327544832