Fabrication of paper-based gradient generators.

Paper-based microfluidic devices are one of the most promising applications of microfluidics because of the cheap cost of materials and fabrication, reduced sample and reagent consumption and device portability. Such devices would be ideal for use in locations with limited medical resources, like in...

Full description

Saved in:
Bibliographic Details
Main Author: Goh, Joel Tze Zhong.
Other Authors: School of Chemical and Biomedical Engineering
Format: Final Year Project
Language:English
Published: 2013
Subjects:
Online Access:http://hdl.handle.net/10356/53951
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-53951
record_format dspace
spelling sg-ntu-dr.10356-539512023-03-03T15:39:56Z Fabrication of paper-based gradient generators. Goh, Joel Tze Zhong. School of Chemical and Biomedical Engineering Kang Yuejun DRNTU::Engineering::Bioengineering Paper-based microfluidic devices are one of the most promising applications of microfluidics because of the cheap cost of materials and fabrication, reduced sample and reagent consumption and device portability. Such devices would be ideal for use in locations with limited medical resources, like in developing countries or during military field assignments. This project explores the use of paper-based microfluidic devices as a gradient generator. Testing against a series of varying concentrations is often necessary in chemical analyses. Gradient profiles are also important for the study of cellular responses. Using paper-based microfluidic devices could present a strategy for the development of high throughput chemical analyses and portable point-of-care diagnostic tools. A device is proposed here consisting of a paper chip sandwiched between two layers of PDMS and secured together between plastic mounting plates with screws. Potassium ferricyanide and red food dye were used to successfully generate a linear concentration gradient. These coloured solutions underwent a series of dilutions as the fluid streams split and recombined in the microfluidic network. The greyscale intensities of the outlet reservoirs were analysed using imaging software, and plotted to produce a liner graph. The next step would be to determine if gradients can also be successfully generated using cell culture mediums and various growth factors. Bachelor of Engineering (Chemical and Biomolecular Engineering) 2013-06-10T07:28:53Z 2013-06-10T07:28:53Z 2013 2013 Final Year Project (FYP) http://hdl.handle.net/10356/53951 en Nanyang Technological University 37 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Bioengineering
spellingShingle DRNTU::Engineering::Bioengineering
Goh, Joel Tze Zhong.
Fabrication of paper-based gradient generators.
description Paper-based microfluidic devices are one of the most promising applications of microfluidics because of the cheap cost of materials and fabrication, reduced sample and reagent consumption and device portability. Such devices would be ideal for use in locations with limited medical resources, like in developing countries or during military field assignments. This project explores the use of paper-based microfluidic devices as a gradient generator. Testing against a series of varying concentrations is often necessary in chemical analyses. Gradient profiles are also important for the study of cellular responses. Using paper-based microfluidic devices could present a strategy for the development of high throughput chemical analyses and portable point-of-care diagnostic tools. A device is proposed here consisting of a paper chip sandwiched between two layers of PDMS and secured together between plastic mounting plates with screws. Potassium ferricyanide and red food dye were used to successfully generate a linear concentration gradient. These coloured solutions underwent a series of dilutions as the fluid streams split and recombined in the microfluidic network. The greyscale intensities of the outlet reservoirs were analysed using imaging software, and plotted to produce a liner graph. The next step would be to determine if gradients can also be successfully generated using cell culture mediums and various growth factors.
author2 School of Chemical and Biomedical Engineering
author_facet School of Chemical and Biomedical Engineering
Goh, Joel Tze Zhong.
format Final Year Project
author Goh, Joel Tze Zhong.
author_sort Goh, Joel Tze Zhong.
title Fabrication of paper-based gradient generators.
title_short Fabrication of paper-based gradient generators.
title_full Fabrication of paper-based gradient generators.
title_fullStr Fabrication of paper-based gradient generators.
title_full_unstemmed Fabrication of paper-based gradient generators.
title_sort fabrication of paper-based gradient generators.
publishDate 2013
url http://hdl.handle.net/10356/53951
_version_ 1759857527053352960