Study on compressive properties of microwave cured composites

A study on the compressive properties of microwave cured glass fibre/epoxy composite has been carried out and the results are compared with those of thermally cured (autoclave) composites. Fractographic analysis has also been carried out after compression tests were done. Two orientations [0/90] and...

Full description

Saved in:
Bibliographic Details
Main Author: Yap, Yee Ling.
Other Authors: Sunil Chandrakant Joshi
Format: Final Year Project
Language:English
Published: 2013
Subjects:
Online Access:http://hdl.handle.net/10356/53987
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-53987
record_format dspace
spelling sg-ntu-dr.10356-539872023-03-04T18:54:31Z Study on compressive properties of microwave cured composites Yap, Yee Ling. Sunil Chandrakant Joshi School of Mechanical and Aerospace Engineering DRNTU::Engineering::Materials::Composite materials DRNTU::Engineering::Materials::Material testing and characterization DRNTU::Engineering::Materials::Mechanical strength of materials A study on the compressive properties of microwave cured glass fibre/epoxy composite has been carried out and the results are compared with those of thermally cured (autoclave) composites. Fractographic analysis has also been carried out after compression tests were done. Two orientations [0/90] and [±45] glass fibre/epoxy prepregs were fabricated and were cured in an autoclave and in a commercial domestic microwave oven with operating frequency of 2450 MHz. Compressive properties of the microwave cured [0/90] and [±45] composites were comparable to that of autoclave cured ones. Better compressive strengths were achieved for both orientations of the microwave cured specimens when the pressure applied was even and uniform for compaction of laminates and to remove volatiles, and sufficient cooling was given after curing process to prevent residual stresses. Fractographic analysis was carried out to observe the failure modes of both the microwave and autoclave cured composites. Residual stresses were more likely to be present in the microwave cured composites due to the current curing technique and set up, resulting in higher occurrence of residual stress induced failure modes that were only found in the microwave cured specimens. Microwave curing has proven to be significantly faster than thermal curing and the tremendous cut down in curing time can be translated into energy and cost saving. Further improvement in the pressure application method in the microwave curing process could ease the problem of large scattering of data due to non-uniform curing in the current project. Bachelor of Engineering (Aerospace Engineering) 2013-06-11T03:49:43Z 2013-06-11T03:49:43Z 2013 2013 Final Year Project (FYP) http://hdl.handle.net/10356/53987 en Nanyang Technological University 86 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Materials::Composite materials
DRNTU::Engineering::Materials::Material testing and characterization
DRNTU::Engineering::Materials::Mechanical strength of materials
spellingShingle DRNTU::Engineering::Materials::Composite materials
DRNTU::Engineering::Materials::Material testing and characterization
DRNTU::Engineering::Materials::Mechanical strength of materials
Yap, Yee Ling.
Study on compressive properties of microwave cured composites
description A study on the compressive properties of microwave cured glass fibre/epoxy composite has been carried out and the results are compared with those of thermally cured (autoclave) composites. Fractographic analysis has also been carried out after compression tests were done. Two orientations [0/90] and [±45] glass fibre/epoxy prepregs were fabricated and were cured in an autoclave and in a commercial domestic microwave oven with operating frequency of 2450 MHz. Compressive properties of the microwave cured [0/90] and [±45] composites were comparable to that of autoclave cured ones. Better compressive strengths were achieved for both orientations of the microwave cured specimens when the pressure applied was even and uniform for compaction of laminates and to remove volatiles, and sufficient cooling was given after curing process to prevent residual stresses. Fractographic analysis was carried out to observe the failure modes of both the microwave and autoclave cured composites. Residual stresses were more likely to be present in the microwave cured composites due to the current curing technique and set up, resulting in higher occurrence of residual stress induced failure modes that were only found in the microwave cured specimens. Microwave curing has proven to be significantly faster than thermal curing and the tremendous cut down in curing time can be translated into energy and cost saving. Further improvement in the pressure application method in the microwave curing process could ease the problem of large scattering of data due to non-uniform curing in the current project.
author2 Sunil Chandrakant Joshi
author_facet Sunil Chandrakant Joshi
Yap, Yee Ling.
format Final Year Project
author Yap, Yee Ling.
author_sort Yap, Yee Ling.
title Study on compressive properties of microwave cured composites
title_short Study on compressive properties of microwave cured composites
title_full Study on compressive properties of microwave cured composites
title_fullStr Study on compressive properties of microwave cured composites
title_full_unstemmed Study on compressive properties of microwave cured composites
title_sort study on compressive properties of microwave cured composites
publishDate 2013
url http://hdl.handle.net/10356/53987
_version_ 1759857615377006592