Measurement of an enlarged blood pump model

Centrifugal pumps have been used as a form of circulatory assist device for more than a decade now. However they are still plagued by hemolysis and the formation of thrombi, and these have greatly limited their life as a replacement of our vulnerable heart. With the advent of the magnetically suspen...

Full description

Saved in:
Bibliographic Details
Main Author: Leo, Hua Liang.
Other Authors: Chua, Leok Poh
Format: Theses and Dissertations
Published: 2008
Subjects:
Online Access:http://hdl.handle.net/10356/5955
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
id sg-ntu-dr.10356-5955
record_format dspace
spelling sg-ntu-dr.10356-59552023-03-11T17:05:33Z Measurement of an enlarged blood pump model Leo, Hua Liang. Chua, Leok Poh School of Mechanical and Production Engineering DRNTU::Engineering::Bioengineering Centrifugal pumps have been used as a form of circulatory assist device for more than a decade now. However they are still plagued by hemolysis and the formation of thrombi, and these have greatly limited their life as a replacement of our vulnerable heart. With the advent of the magnetically suspended blood pump in artificial heart research, the index of hemolysis has greatly been reduced. However, there is still lack of measurements on the flow profile within the pump due to its small size. Hence a five times scaled up model of the Bio-Centrifugal pump was developed, using Laser Doppler Anemometer (LDA) to measure the flow field in between the blade passages of three different impellers configuration. Master of Engineering (MPE) 2008-09-17T11:03:16Z 2008-09-17T11:03:16Z 2000 2000 Thesis http://hdl.handle.net/10356/5955 Nanyang Technological University application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
topic DRNTU::Engineering::Bioengineering
spellingShingle DRNTU::Engineering::Bioengineering
Leo, Hua Liang.
Measurement of an enlarged blood pump model
description Centrifugal pumps have been used as a form of circulatory assist device for more than a decade now. However they are still plagued by hemolysis and the formation of thrombi, and these have greatly limited their life as a replacement of our vulnerable heart. With the advent of the magnetically suspended blood pump in artificial heart research, the index of hemolysis has greatly been reduced. However, there is still lack of measurements on the flow profile within the pump due to its small size. Hence a five times scaled up model of the Bio-Centrifugal pump was developed, using Laser Doppler Anemometer (LDA) to measure the flow field in between the blade passages of three different impellers configuration.
author2 Chua, Leok Poh
author_facet Chua, Leok Poh
Leo, Hua Liang.
format Theses and Dissertations
author Leo, Hua Liang.
author_sort Leo, Hua Liang.
title Measurement of an enlarged blood pump model
title_short Measurement of an enlarged blood pump model
title_full Measurement of an enlarged blood pump model
title_fullStr Measurement of an enlarged blood pump model
title_full_unstemmed Measurement of an enlarged blood pump model
title_sort measurement of an enlarged blood pump model
publishDate 2008
url http://hdl.handle.net/10356/5955
_version_ 1761781553274290176