Studies on thermal management in green data centres

In today’s world, almost all businesses and trades have online platforms available. Following this trend, the number of data centres have been expanding tremendously. Companies providing essential and important services such as banking would require reliable and consistent data source. Hence, oversu...

Full description

Saved in:
Bibliographic Details
Main Author: Chew, Xin Ni
Other Authors: School of Mechanical and Aerospace Engineering
Format: Final Year Project
Language:English
Published: 2014
Subjects:
Online Access:http://hdl.handle.net/10356/60356
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-60356
record_format dspace
spelling sg-ntu-dr.10356-603562023-03-04T18:40:46Z Studies on thermal management in green data centres Chew, Xin Ni School of Mechanical and Aerospace Engineering Wong Yew Wah DRNTU::Engineering In today’s world, almost all businesses and trades have online platforms available. Following this trend, the number of data centres have been expanding tremendously. Companies providing essential and important services such as banking would require reliable and consistent data source. Hence, oversupplying of power is often the adopted approach to prevent failures; which in turn leads to depletion, wastage of natural resources and the high cost incurred. Therefore, it is of paramount importance to carefully examine and manage all data centres so as to avoid detrimental and undesirable scenarios. Existing studies were mostly done on room level cooling based on past technology, which is insufficient for the new blade servers; more efficient cooling at the server level can be explored. This project focuses on the generic layout of servers within a rack, airflow and thermal profiles within a server and how these factors would affect the overall airflow pattern and thermal profile within the rack. Dell™ PowerEdge™ R620 blade server is being used specifically in this case study. Computational Fluid Dynamic (CFD) models were built using the ICEPAK software. Detailed model of server was modeled to carry out simulations of airflow, heat transfer and thermal variations are studied. The models are depicted as close as possible to the actual servers so as to capture realistic datas. With the aim of understanding the complex airflow and thermal patterns in existing racks, each unit of the server modeled would eventually be represented by an equivalent reduced model so as to cut down on computational time and at the same time simplifying the rack-room modeling. Airflows and heat dissipation patterns would be predictable upon understanding of server-rack interaction. Parametric studies on consolidation of workloads from various pre-determined factors can be carried out. Bachelor of Engineering (Mechanical Engineering) 2014-05-27T01:30:27Z 2014-05-27T01:30:27Z 2014 2014 Final Year Project (FYP) http://hdl.handle.net/10356/60356 en Nanyang Technological University 65 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering
spellingShingle DRNTU::Engineering
Chew, Xin Ni
Studies on thermal management in green data centres
description In today’s world, almost all businesses and trades have online platforms available. Following this trend, the number of data centres have been expanding tremendously. Companies providing essential and important services such as banking would require reliable and consistent data source. Hence, oversupplying of power is often the adopted approach to prevent failures; which in turn leads to depletion, wastage of natural resources and the high cost incurred. Therefore, it is of paramount importance to carefully examine and manage all data centres so as to avoid detrimental and undesirable scenarios. Existing studies were mostly done on room level cooling based on past technology, which is insufficient for the new blade servers; more efficient cooling at the server level can be explored. This project focuses on the generic layout of servers within a rack, airflow and thermal profiles within a server and how these factors would affect the overall airflow pattern and thermal profile within the rack. Dell™ PowerEdge™ R620 blade server is being used specifically in this case study. Computational Fluid Dynamic (CFD) models were built using the ICEPAK software. Detailed model of server was modeled to carry out simulations of airflow, heat transfer and thermal variations are studied. The models are depicted as close as possible to the actual servers so as to capture realistic datas. With the aim of understanding the complex airflow and thermal patterns in existing racks, each unit of the server modeled would eventually be represented by an equivalent reduced model so as to cut down on computational time and at the same time simplifying the rack-room modeling. Airflows and heat dissipation patterns would be predictable upon understanding of server-rack interaction. Parametric studies on consolidation of workloads from various pre-determined factors can be carried out.
author2 School of Mechanical and Aerospace Engineering
author_facet School of Mechanical and Aerospace Engineering
Chew, Xin Ni
format Final Year Project
author Chew, Xin Ni
author_sort Chew, Xin Ni
title Studies on thermal management in green data centres
title_short Studies on thermal management in green data centres
title_full Studies on thermal management in green data centres
title_fullStr Studies on thermal management in green data centres
title_full_unstemmed Studies on thermal management in green data centres
title_sort studies on thermal management in green data centres
publishDate 2014
url http://hdl.handle.net/10356/60356
_version_ 1759855420813344768