Development of experimental setup and testing of a cross vane expander-compressor unit in a refrigeration system

With the discovery of the two daunting concerns that the Earth is facing, which are the depletion of ozone layer and global warming, there is a need to develop environmental friendly refrigeration and air conditioning systems. Since then, carbon dioxide has been proposed as an alternative solution f...

Full description

Saved in:
Bibliographic Details
Main Author: Khoo, Zhong Xun
Other Authors: Ooi Kim Tiow
Format: Final Year Project
Language:English
Published: 2014
Subjects:
Online Access:http://hdl.handle.net/10356/60954
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-60954
record_format dspace
spelling sg-ntu-dr.10356-609542023-03-04T18:40:45Z Development of experimental setup and testing of a cross vane expander-compressor unit in a refrigeration system Khoo, Zhong Xun Ooi Kim Tiow School of Mechanical and Aerospace Engineering Energy Research Group DRNTU::Engineering With the discovery of the two daunting concerns that the Earth is facing, which are the depletion of ozone layer and global warming, there is a need to develop environmental friendly refrigeration and air conditioning systems. Since then, carbon dioxide has been proposed as an alternative solution for the synthetic refrigerants. However, due to the large expansion loss during the expansion process, the efficiency of the transcritical carbon dioxide refrigeration cycle is very low. Hence to overcome this limitation, the conventional expansion valve is replaced by an expander for work recovery. In this study, a new type of expander-compressor unit named as the cross vane expander-compressor unit is presented and its working principles are demonstrated. This type of expander-compressor unit performs the expansion and compression processes simultaneously and utilizes the recovered energy for the compression process. An experimental test bed is developed next to prove that the expander-compressor prototype is able to perform accordingly to the theoretical design. The equipment and the measurement devices required and selected for the experiment are discussed and presented. The equipment consists of the evaporator, condenser and motor. The measurement devices include the flow meters, thermocouples, torque meter, pressure transducers, and DAQ system. Before the pressure transducers are installed on the experimental setup for measurement purposes, they are calibrated first. The calibration results of the pressure transducers have showed that they exhibit high linearity with a R2 value of 1.00. Lastly, to avoid the prototype from failure due to the exposure to high pressure refrigerant or high tangential force, numerical stress analyses for the various critical components have been performed. These components comprise the vane, inner cylinder body, outer cylinder, housing, and the shaft. Based on the simulation results, these components are able to withstand the stresses that arise due to the pressure difference. However, this is not the case for the maximum deformation that the components will experience. The maximum deformations of the housing and the shaft are either close to the maximum acceptable clearance limit or have exceeded the limit. Hence, this can pose a problem to the operation of the prototype and may eventually lead to the failure of the prototype. On the other hand, the deformations of the vane are found to have negligible effect on the thermodynamic properties of the refrigerant as well. Bachelor of Engineering (Mechanical Engineering) 2014-06-03T07:46:28Z 2014-06-03T07:46:28Z 2014 2014 Final Year Project (FYP) http://hdl.handle.net/10356/60954 en Nanyang Technological University 155 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering
spellingShingle DRNTU::Engineering
Khoo, Zhong Xun
Development of experimental setup and testing of a cross vane expander-compressor unit in a refrigeration system
description With the discovery of the two daunting concerns that the Earth is facing, which are the depletion of ozone layer and global warming, there is a need to develop environmental friendly refrigeration and air conditioning systems. Since then, carbon dioxide has been proposed as an alternative solution for the synthetic refrigerants. However, due to the large expansion loss during the expansion process, the efficiency of the transcritical carbon dioxide refrigeration cycle is very low. Hence to overcome this limitation, the conventional expansion valve is replaced by an expander for work recovery. In this study, a new type of expander-compressor unit named as the cross vane expander-compressor unit is presented and its working principles are demonstrated. This type of expander-compressor unit performs the expansion and compression processes simultaneously and utilizes the recovered energy for the compression process. An experimental test bed is developed next to prove that the expander-compressor prototype is able to perform accordingly to the theoretical design. The equipment and the measurement devices required and selected for the experiment are discussed and presented. The equipment consists of the evaporator, condenser and motor. The measurement devices include the flow meters, thermocouples, torque meter, pressure transducers, and DAQ system. Before the pressure transducers are installed on the experimental setup for measurement purposes, they are calibrated first. The calibration results of the pressure transducers have showed that they exhibit high linearity with a R2 value of 1.00. Lastly, to avoid the prototype from failure due to the exposure to high pressure refrigerant or high tangential force, numerical stress analyses for the various critical components have been performed. These components comprise the vane, inner cylinder body, outer cylinder, housing, and the shaft. Based on the simulation results, these components are able to withstand the stresses that arise due to the pressure difference. However, this is not the case for the maximum deformation that the components will experience. The maximum deformations of the housing and the shaft are either close to the maximum acceptable clearance limit or have exceeded the limit. Hence, this can pose a problem to the operation of the prototype and may eventually lead to the failure of the prototype. On the other hand, the deformations of the vane are found to have negligible effect on the thermodynamic properties of the refrigerant as well.
author2 Ooi Kim Tiow
author_facet Ooi Kim Tiow
Khoo, Zhong Xun
format Final Year Project
author Khoo, Zhong Xun
author_sort Khoo, Zhong Xun
title Development of experimental setup and testing of a cross vane expander-compressor unit in a refrigeration system
title_short Development of experimental setup and testing of a cross vane expander-compressor unit in a refrigeration system
title_full Development of experimental setup and testing of a cross vane expander-compressor unit in a refrigeration system
title_fullStr Development of experimental setup and testing of a cross vane expander-compressor unit in a refrigeration system
title_full_unstemmed Development of experimental setup and testing of a cross vane expander-compressor unit in a refrigeration system
title_sort development of experimental setup and testing of a cross vane expander-compressor unit in a refrigeration system
publishDate 2014
url http://hdl.handle.net/10356/60954
_version_ 1759855565035536384