Proximal tibial strains following unicompartmental knee arthroplasty (UKA) : a finite element study
Stress fracture on the medial tibia plateau following unicompartmental knee arthroplasty (UKA) has been reported for years yet the reason for such occurrences has not been fully understood. Previous indications showed that the strength of the tibia was compromised and the support beneath the implant...
Saved in:
主要作者: | Xiao, Xiao |
---|---|
其他作者: | Chou Siaw Meng |
格式: | Final Year Project |
語言: | English |
出版: |
2014
|