Non-destructive testing techniques for inspection of heat exchanger tubes

This dissertation covers the basic principles and methodologies of some nondestructive testing techniques (NDTs) on heat exchanger tubes used in the petrochemical industry. This project focuses on analysis and comparison of five NDT techniques. They are conventional eddy current testing (ECT), remot...

Full description

Saved in:
Bibliographic Details
Main Author: Ren, Yong.
Other Authors: Zhong, Zhaowei
Format: Theses and Dissertations
Published: 2008
Subjects:
Online Access:http://hdl.handle.net/10356/6324
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
id sg-ntu-dr.10356-6324
record_format dspace
spelling sg-ntu-dr.10356-63242023-03-11T17:04:33Z Non-destructive testing techniques for inspection of heat exchanger tubes Ren, Yong. Zhong, Zhaowei School of Mechanical and Production Engineering DRNTU::Engineering::Mechanical engineering This dissertation covers the basic principles and methodologies of some nondestructive testing techniques (NDTs) on heat exchanger tubes used in the petrochemical industry. This project focuses on analysis and comparison of five NDT techniques. They are conventional eddy current testing (ECT), remote field eddy current testing (RFT), magnetic flux leakage testing (MFL), ultrasonic internal rotary inspection system (IRIS) and optical technique - videoprobe. Three materials of aluminum brass, copper nickel alloys and carbon steel were used. The aluminum brass samples with real corrosion, pits and cracks were used for comparison to determine the effectiveness of ECT, IRIS and videoprobe techniques. One copper nickel tube and three carbon steel tubes with artificial flaws were tested. The copper nickel tube was tested by ECT, IRIS and videoprobe while the carbon steel tubes were inspected by RFT, MFLT and IRIS techniques. The emphasis was put on comparison of different techniques regarding the flaw detectability. The author has concluded through experiments that the eddy current test may give higher percentage of tube wall loss (thickness thining) than actual defect depth if it is on the internal surface. The baffle support signal in remote field eddy current testing will shadow the defect signals if the defects are small and under the support baffle. The amplitude of the defect signal in magnetic flux leakage testing is related not only to its depth but also its area. The minimum detectable thickness of the internal rotary inspection system is limited to its resolution. Master of Science (Precision Engineering) 2008-09-17T11:11:59Z 2008-09-17T11:11:59Z 2003 2003 Thesis http://hdl.handle.net/10356/6324 Nanyang Technological University application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
topic DRNTU::Engineering::Mechanical engineering
spellingShingle DRNTU::Engineering::Mechanical engineering
Ren, Yong.
Non-destructive testing techniques for inspection of heat exchanger tubes
description This dissertation covers the basic principles and methodologies of some nondestructive testing techniques (NDTs) on heat exchanger tubes used in the petrochemical industry. This project focuses on analysis and comparison of five NDT techniques. They are conventional eddy current testing (ECT), remote field eddy current testing (RFT), magnetic flux leakage testing (MFL), ultrasonic internal rotary inspection system (IRIS) and optical technique - videoprobe. Three materials of aluminum brass, copper nickel alloys and carbon steel were used. The aluminum brass samples with real corrosion, pits and cracks were used for comparison to determine the effectiveness of ECT, IRIS and videoprobe techniques. One copper nickel tube and three carbon steel tubes with artificial flaws were tested. The copper nickel tube was tested by ECT, IRIS and videoprobe while the carbon steel tubes were inspected by RFT, MFLT and IRIS techniques. The emphasis was put on comparison of different techniques regarding the flaw detectability. The author has concluded through experiments that the eddy current test may give higher percentage of tube wall loss (thickness thining) than actual defect depth if it is on the internal surface. The baffle support signal in remote field eddy current testing will shadow the defect signals if the defects are small and under the support baffle. The amplitude of the defect signal in magnetic flux leakage testing is related not only to its depth but also its area. The minimum detectable thickness of the internal rotary inspection system is limited to its resolution.
author2 Zhong, Zhaowei
author_facet Zhong, Zhaowei
Ren, Yong.
format Theses and Dissertations
author Ren, Yong.
author_sort Ren, Yong.
title Non-destructive testing techniques for inspection of heat exchanger tubes
title_short Non-destructive testing techniques for inspection of heat exchanger tubes
title_full Non-destructive testing techniques for inspection of heat exchanger tubes
title_fullStr Non-destructive testing techniques for inspection of heat exchanger tubes
title_full_unstemmed Non-destructive testing techniques for inspection of heat exchanger tubes
title_sort non-destructive testing techniques for inspection of heat exchanger tubes
publishDate 2008
url http://hdl.handle.net/10356/6324
_version_ 1761781783131586560