ST-23AB : A modular system for prefabricated pre-finished volumetric construction (PPVC) - joint behaviour

Prefabricated Pre-finished Volumetric Construction (PPVC) technology, generally known as modular construction, is a new construction technology funded by Singapore government to enhance construction productivity. The new construction technology introduced has gain fast recognition for its inherent a...

Full description

Saved in:
Bibliographic Details
Main Author: Yang, Jocelyn Yun Xuan
Other Authors: Chiew Sing Ping
Format: Final Year Project
Language:English
Published: 2015
Subjects:
Online Access:http://hdl.handle.net/10356/63483
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-63483
record_format dspace
spelling sg-ntu-dr.10356-634832023-03-03T16:50:48Z ST-23AB : A modular system for prefabricated pre-finished volumetric construction (PPVC) - joint behaviour Yang, Jocelyn Yun Xuan Chiew Sing Ping School of Civil and Environmental Engineering DRNTU::Engineering::Civil engineering::Construction technology Prefabricated Pre-finished Volumetric Construction (PPVC) technology, generally known as modular construction, is a new construction technology funded by Singapore government to enhance construction productivity. The new construction technology introduced has gain fast recognition for its inherent advantage to reduce overall construction time, site disruption, vehicular traffic and improves overall safety and security. Modular construction can be summarised into four stages: design stage, manufacturing stage, transportation stage and erection stage. With softwares like the Building information Modelling (BIM), engineers are able to generate realistic 3D visualisations of the modular building for developers for final decision making before the manufacturing stage, as design of the modules cannot be changed once manufacturing starts. In the design for modular construction, the joint connection plays a crucial role of transferring load and maintaining structural integrity. Unlike traditional construction system, modular connection system make use of access holes at the beam-column joint to bolt and connect laterally and vertically adjacent modules. In this paper, a new type of modular connection system named LT steel connection system comprising I-beam, rectangular hollow section column and cruciform base is proposed. There are 12 connection types with a total of 24 finite element models established to stimulate the bending behaviour in the major and minor axis using Abaqus. Considering symmetry of several models, half or quarter of the joint connection were taken for analysis, reducing total time taken for the numerical analysis. The results revealed that failure takes place at interconnection of beam and cruciform base under bending. Failure tends to occur in minor axis for L shape connections and major axis for T shape connections. Numerical analysis shows that the ultimate bending strength for the L shape connections is larger in major axis than in minor axis, whereas T shape connections have larger ultimate bending strength in minor axis than in major axis. The endplate thickness of the cruciform base has considerable impact on ultimate bending strength of the joint connection. For a same connection type, a 16mm thick endplate results in a larger ultimate bending capacity than a 9mm thick endplate. The strengthen result of having the 16mm thick endplate is more prominent to the connections that is subjected to bending in the axis that is more likely to fail for the connection type. Bachelor of Engineering (Civil) 2015-05-14T03:36:37Z 2015-05-14T03:36:37Z 2015 2015 Final Year Project (FYP) http://hdl.handle.net/10356/63483 en Nanyang Technological University 48 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Civil engineering::Construction technology
spellingShingle DRNTU::Engineering::Civil engineering::Construction technology
Yang, Jocelyn Yun Xuan
ST-23AB : A modular system for prefabricated pre-finished volumetric construction (PPVC) - joint behaviour
description Prefabricated Pre-finished Volumetric Construction (PPVC) technology, generally known as modular construction, is a new construction technology funded by Singapore government to enhance construction productivity. The new construction technology introduced has gain fast recognition for its inherent advantage to reduce overall construction time, site disruption, vehicular traffic and improves overall safety and security. Modular construction can be summarised into four stages: design stage, manufacturing stage, transportation stage and erection stage. With softwares like the Building information Modelling (BIM), engineers are able to generate realistic 3D visualisations of the modular building for developers for final decision making before the manufacturing stage, as design of the modules cannot be changed once manufacturing starts. In the design for modular construction, the joint connection plays a crucial role of transferring load and maintaining structural integrity. Unlike traditional construction system, modular connection system make use of access holes at the beam-column joint to bolt and connect laterally and vertically adjacent modules. In this paper, a new type of modular connection system named LT steel connection system comprising I-beam, rectangular hollow section column and cruciform base is proposed. There are 12 connection types with a total of 24 finite element models established to stimulate the bending behaviour in the major and minor axis using Abaqus. Considering symmetry of several models, half or quarter of the joint connection were taken for analysis, reducing total time taken for the numerical analysis. The results revealed that failure takes place at interconnection of beam and cruciform base under bending. Failure tends to occur in minor axis for L shape connections and major axis for T shape connections. Numerical analysis shows that the ultimate bending strength for the L shape connections is larger in major axis than in minor axis, whereas T shape connections have larger ultimate bending strength in minor axis than in major axis. The endplate thickness of the cruciform base has considerable impact on ultimate bending strength of the joint connection. For a same connection type, a 16mm thick endplate results in a larger ultimate bending capacity than a 9mm thick endplate. The strengthen result of having the 16mm thick endplate is more prominent to the connections that is subjected to bending in the axis that is more likely to fail for the connection type.
author2 Chiew Sing Ping
author_facet Chiew Sing Ping
Yang, Jocelyn Yun Xuan
format Final Year Project
author Yang, Jocelyn Yun Xuan
author_sort Yang, Jocelyn Yun Xuan
title ST-23AB : A modular system for prefabricated pre-finished volumetric construction (PPVC) - joint behaviour
title_short ST-23AB : A modular system for prefabricated pre-finished volumetric construction (PPVC) - joint behaviour
title_full ST-23AB : A modular system for prefabricated pre-finished volumetric construction (PPVC) - joint behaviour
title_fullStr ST-23AB : A modular system for prefabricated pre-finished volumetric construction (PPVC) - joint behaviour
title_full_unstemmed ST-23AB : A modular system for prefabricated pre-finished volumetric construction (PPVC) - joint behaviour
title_sort st-23ab : a modular system for prefabricated pre-finished volumetric construction (ppvc) - joint behaviour
publishDate 2015
url http://hdl.handle.net/10356/63483
_version_ 1759855775887392768