Theoretical study of separation of dehumidification and cooling in air conditioning systems

The increase in energy prices and global warming effects has raised the concern of reducing energy consumption. In countries with hot and humid climate like Singapore, the dehumidification process makes air conditioning (A/C) systems very energy intensive. In Singapore, A/C systems accounts for abou...

Full description

Saved in:
Bibliographic Details
Main Author: Ong, Jun Xiong
Other Authors: Ooi Kim Tiow
Format: Final Year Project
Language:English
Published: 2015
Subjects:
Online Access:http://hdl.handle.net/10356/63689
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-63689
record_format dspace
spelling sg-ntu-dr.10356-636892023-03-04T19:03:06Z Theoretical study of separation of dehumidification and cooling in air conditioning systems Ong, Jun Xiong Ooi Kim Tiow School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering The increase in energy prices and global warming effects has raised the concern of reducing energy consumption. In countries with hot and humid climate like Singapore, the dehumidification process makes air conditioning (A/C) systems very energy intensive. In Singapore, A/C systems accounts for about 50% of the power consumption in most buildings. To reduce the drawback of A/C systems, the separation of dehumidification and cooling in A/C systems has been introduced. In this project, theoretical studies are carried out to analyse the effectiveness of the separation of dehumidification and cooling in A/C systems via the desiccant dehumidification method, over a wide range of ambient and indoor air conditions, by determining the enthalpy of moist air at each of the points and the corresponding change in enthalpy between the points of interest. For the desiccant dehumidification method, Silica gel is chosen as the desiccant material as it is reusable via heating. Results for the change in enthalpy of moist air show that the separation of dehumidification and cooling in A/C systems is about 30% ~ 65% more effective than conventional air conditioning systems, over a wide range of operating conditions. Cost analysis shows that the separation of dehumidification and cooling in A/C system, as compared to the conventional air conditioning system, can reduce the electricity consumption cost by about 35% to 60%, which is consistent with the results from the theoretical calculations. The results from the various studies show that the separation of dehumidification and cooling in A/C system is more effective than, and a better alternative to, the conventional air conditioning system. Bachelor of Engineering (Mechanical Engineering) 2015-05-18T06:16:22Z 2015-05-18T06:16:22Z 2015 2015 Final Year Project (FYP) http://hdl.handle.net/10356/63689 en Nanyang Technological University 83 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering
spellingShingle DRNTU::Engineering::Mechanical engineering
Ong, Jun Xiong
Theoretical study of separation of dehumidification and cooling in air conditioning systems
description The increase in energy prices and global warming effects has raised the concern of reducing energy consumption. In countries with hot and humid climate like Singapore, the dehumidification process makes air conditioning (A/C) systems very energy intensive. In Singapore, A/C systems accounts for about 50% of the power consumption in most buildings. To reduce the drawback of A/C systems, the separation of dehumidification and cooling in A/C systems has been introduced. In this project, theoretical studies are carried out to analyse the effectiveness of the separation of dehumidification and cooling in A/C systems via the desiccant dehumidification method, over a wide range of ambient and indoor air conditions, by determining the enthalpy of moist air at each of the points and the corresponding change in enthalpy between the points of interest. For the desiccant dehumidification method, Silica gel is chosen as the desiccant material as it is reusable via heating. Results for the change in enthalpy of moist air show that the separation of dehumidification and cooling in A/C systems is about 30% ~ 65% more effective than conventional air conditioning systems, over a wide range of operating conditions. Cost analysis shows that the separation of dehumidification and cooling in A/C system, as compared to the conventional air conditioning system, can reduce the electricity consumption cost by about 35% to 60%, which is consistent with the results from the theoretical calculations. The results from the various studies show that the separation of dehumidification and cooling in A/C system is more effective than, and a better alternative to, the conventional air conditioning system.
author2 Ooi Kim Tiow
author_facet Ooi Kim Tiow
Ong, Jun Xiong
format Final Year Project
author Ong, Jun Xiong
author_sort Ong, Jun Xiong
title Theoretical study of separation of dehumidification and cooling in air conditioning systems
title_short Theoretical study of separation of dehumidification and cooling in air conditioning systems
title_full Theoretical study of separation of dehumidification and cooling in air conditioning systems
title_fullStr Theoretical study of separation of dehumidification and cooling in air conditioning systems
title_full_unstemmed Theoretical study of separation of dehumidification and cooling in air conditioning systems
title_sort theoretical study of separation of dehumidification and cooling in air conditioning systems
publishDate 2015
url http://hdl.handle.net/10356/63689
_version_ 1759855693326712832