Simultaneous strain measurements of knee ligaments

Ligaments injuries are commonly found among athletes and they occur due to adverse combinations of internal and external forces and torques; the most common injury being the anterior cruciate ligament (ACL) tear. The purposes of this study are: firstly, to design and modify an existing custom-design...

Full description

Saved in:
Bibliographic Details
Main Author: Ng, Eugene Zhong Hui
Other Authors: Chou Siaw Meng
Format: Final Year Project
Language:English
Published: 2015
Subjects:
Online Access:http://hdl.handle.net/10356/63691
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-63691
record_format dspace
spelling sg-ntu-dr.10356-636912023-03-04T18:48:01Z Simultaneous strain measurements of knee ligaments Ng, Eugene Zhong Hui Chou Siaw Meng School of Mechanical and Aerospace Engineering Singapore General Hospital DRNTU::Engineering::Mechanical engineering::Mechanics and dynamics Ligaments injuries are commonly found among athletes and they occur due to adverse combinations of internal and external forces and torques; the most common injury being the anterior cruciate ligament (ACL) tear. The purposes of this study are: firstly, to design and modify an existing custom-designed knee fixture which allows multiple degree of freedom of the knee, and secondly, to assess the strain responses of all ligaments simultaneously under various loading conditions. Computer-aided design software, Solidworks, was used to simulate the new design and fabrication was done in Nanyang Technological University (NTU) manufacturing laboratory. Porcine specimen was used to conduct preliminary test to evaluate the functionality of the newly-designed fixture. Experiment was then conducted on cadaveric knee. DVRT (MicroStrain Inc, Williston, Vermont), with a linear range of ± 3 mm was calibrated and implanted into the ligaments by its barbed prongs. Due to limitations from the transducer, only the strain values of the medial collateral ligament (MCL) and lateral collateral ligament (LCL) were recorded. Two series of tests were performed: (1) 2.kg, 5kg and 7.5kg anterior and posterior directed shear load at various flexion angle, (2) 5°, 10° and 15° internal and external tibial rotations at various flexion angle. Both tests were conducted at flexion angles of 0°, 30°, 60° and 90°. Both MCL and LCL were found to be tightest at full extension and relaxed as the knee went into flexion. Strain values of MCL were consistent with past literature as it resisted external tibial axial rotation while being compressed under internal tibial axial rotation. Owing to the inconsistent strain results from LCL, it was hypothesised that LCL is a secondary stabiliser to both internal and external rotation [46]. Future work is required to obtain the strain responses of ACL and posterior cruciate ligament (PCL), along with MCL and LCL simultaneously under combined external loading conditions to understand their interactions in providing total stability in the knee joint. Bachelor of Engineering (Mechanical Engineering) 2015-05-18T06:19:33Z 2015-05-18T06:19:33Z 2015 2015 Final Year Project (FYP) http://hdl.handle.net/10356/63691 en Nanyang Technological University 98 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering::Mechanics and dynamics
spellingShingle DRNTU::Engineering::Mechanical engineering::Mechanics and dynamics
Ng, Eugene Zhong Hui
Simultaneous strain measurements of knee ligaments
description Ligaments injuries are commonly found among athletes and they occur due to adverse combinations of internal and external forces and torques; the most common injury being the anterior cruciate ligament (ACL) tear. The purposes of this study are: firstly, to design and modify an existing custom-designed knee fixture which allows multiple degree of freedom of the knee, and secondly, to assess the strain responses of all ligaments simultaneously under various loading conditions. Computer-aided design software, Solidworks, was used to simulate the new design and fabrication was done in Nanyang Technological University (NTU) manufacturing laboratory. Porcine specimen was used to conduct preliminary test to evaluate the functionality of the newly-designed fixture. Experiment was then conducted on cadaveric knee. DVRT (MicroStrain Inc, Williston, Vermont), with a linear range of ± 3 mm was calibrated and implanted into the ligaments by its barbed prongs. Due to limitations from the transducer, only the strain values of the medial collateral ligament (MCL) and lateral collateral ligament (LCL) were recorded. Two series of tests were performed: (1) 2.kg, 5kg and 7.5kg anterior and posterior directed shear load at various flexion angle, (2) 5°, 10° and 15° internal and external tibial rotations at various flexion angle. Both tests were conducted at flexion angles of 0°, 30°, 60° and 90°. Both MCL and LCL were found to be tightest at full extension and relaxed as the knee went into flexion. Strain values of MCL were consistent with past literature as it resisted external tibial axial rotation while being compressed under internal tibial axial rotation. Owing to the inconsistent strain results from LCL, it was hypothesised that LCL is a secondary stabiliser to both internal and external rotation [46]. Future work is required to obtain the strain responses of ACL and posterior cruciate ligament (PCL), along with MCL and LCL simultaneously under combined external loading conditions to understand their interactions in providing total stability in the knee joint.
author2 Chou Siaw Meng
author_facet Chou Siaw Meng
Ng, Eugene Zhong Hui
format Final Year Project
author Ng, Eugene Zhong Hui
author_sort Ng, Eugene Zhong Hui
title Simultaneous strain measurements of knee ligaments
title_short Simultaneous strain measurements of knee ligaments
title_full Simultaneous strain measurements of knee ligaments
title_fullStr Simultaneous strain measurements of knee ligaments
title_full_unstemmed Simultaneous strain measurements of knee ligaments
title_sort simultaneous strain measurements of knee ligaments
publishDate 2015
url http://hdl.handle.net/10356/63691
_version_ 1759855258581860352