Application of micro-calorimeter for metabolic monitoring

This project aims to develop an optimized experimental set-up of a microcalorimeter for metabolic monitoring applications. In order for an optimization to take place, a PolyDiMethylSiloxane (PDMS) cover was designed and fabricated to reduce the external noise which will in turn improve the accuracy...

Full description

Saved in:
Bibliographic Details
Main Author: Tan, Yi Jun
Other Authors: Zhang Yi Lei
Format: Final Year Project
Language:English
Published: 2015
Subjects:
Online Access:http://hdl.handle.net/10356/64013
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-64013
record_format dspace
spelling sg-ntu-dr.10356-640132023-03-04T18:47:56Z Application of micro-calorimeter for metabolic monitoring Tan, Yi Jun Zhang Yi Lei School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering This project aims to develop an optimized experimental set-up of a microcalorimeter for metabolic monitoring applications. In order for an optimization to take place, a PolyDiMethylSiloxane (PDMS) cover was designed and fabricated to reduce the external noise which will in turn improve the accuracy of the readings collected by the microcalorimeter. The PDMS cover will minimise external noise and confine the sample physically which will reduce errors due to evaporation. Several methods of bonding for the PDMS cover and the microcalorimeter were experimented and tested(Integration, 2013). Bachelor of Engineering (Mechanical Engineering) 2015-05-22T02:09:31Z 2015-05-22T02:09:31Z 2015 2015 Final Year Project (FYP) http://hdl.handle.net/10356/64013 en Nanyang Technological University 48 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering
spellingShingle DRNTU::Engineering::Mechanical engineering
Tan, Yi Jun
Application of micro-calorimeter for metabolic monitoring
description This project aims to develop an optimized experimental set-up of a microcalorimeter for metabolic monitoring applications. In order for an optimization to take place, a PolyDiMethylSiloxane (PDMS) cover was designed and fabricated to reduce the external noise which will in turn improve the accuracy of the readings collected by the microcalorimeter. The PDMS cover will minimise external noise and confine the sample physically which will reduce errors due to evaporation. Several methods of bonding for the PDMS cover and the microcalorimeter were experimented and tested(Integration, 2013).
author2 Zhang Yi Lei
author_facet Zhang Yi Lei
Tan, Yi Jun
format Final Year Project
author Tan, Yi Jun
author_sort Tan, Yi Jun
title Application of micro-calorimeter for metabolic monitoring
title_short Application of micro-calorimeter for metabolic monitoring
title_full Application of micro-calorimeter for metabolic monitoring
title_fullStr Application of micro-calorimeter for metabolic monitoring
title_full_unstemmed Application of micro-calorimeter for metabolic monitoring
title_sort application of micro-calorimeter for metabolic monitoring
publishDate 2015
url http://hdl.handle.net/10356/64013
_version_ 1759856286814437376