Application of micro-calorimeter for metabolic monitoring
This project aims to develop an optimized experimental set-up of a microcalorimeter for metabolic monitoring applications. In order for an optimization to take place, a PolyDiMethylSiloxane (PDMS) cover was designed and fabricated to reduce the external noise which will in turn improve the accuracy...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
2015
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/64013 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-64013 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-640132023-03-04T18:47:56Z Application of micro-calorimeter for metabolic monitoring Tan, Yi Jun Zhang Yi Lei School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering This project aims to develop an optimized experimental set-up of a microcalorimeter for metabolic monitoring applications. In order for an optimization to take place, a PolyDiMethylSiloxane (PDMS) cover was designed and fabricated to reduce the external noise which will in turn improve the accuracy of the readings collected by the microcalorimeter. The PDMS cover will minimise external noise and confine the sample physically which will reduce errors due to evaporation. Several methods of bonding for the PDMS cover and the microcalorimeter were experimented and tested(Integration, 2013). Bachelor of Engineering (Mechanical Engineering) 2015-05-22T02:09:31Z 2015-05-22T02:09:31Z 2015 2015 Final Year Project (FYP) http://hdl.handle.net/10356/64013 en Nanyang Technological University 48 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Mechanical engineering |
spellingShingle |
DRNTU::Engineering::Mechanical engineering Tan, Yi Jun Application of micro-calorimeter for metabolic monitoring |
description |
This project aims to develop an optimized experimental set-up of a microcalorimeter for metabolic monitoring applications. In order for an optimization to take place, a PolyDiMethylSiloxane (PDMS) cover was designed and fabricated to reduce the external noise which will in turn improve the accuracy of the readings collected by the microcalorimeter. The PDMS cover will minimise external noise and confine the sample physically which will reduce errors due to evaporation. Several methods of bonding for the PDMS cover and the microcalorimeter were experimented and tested(Integration, 2013). |
author2 |
Zhang Yi Lei |
author_facet |
Zhang Yi Lei Tan, Yi Jun |
format |
Final Year Project |
author |
Tan, Yi Jun |
author_sort |
Tan, Yi Jun |
title |
Application of micro-calorimeter for metabolic monitoring |
title_short |
Application of micro-calorimeter for metabolic monitoring |
title_full |
Application of micro-calorimeter for metabolic monitoring |
title_fullStr |
Application of micro-calorimeter for metabolic monitoring |
title_full_unstemmed |
Application of micro-calorimeter for metabolic monitoring |
title_sort |
application of micro-calorimeter for metabolic monitoring |
publishDate |
2015 |
url |
http://hdl.handle.net/10356/64013 |
_version_ |
1759856286814437376 |